文献速递甲状腺与颈部外科围术期管理与 ERAS

白光与近红外自体荧光在全甲状腺切除术中识别甲状旁腺的随机对照试验

Randomized Controlled Trial Comparing White Light with Near-Infrared Autofluorescence for Parathyroid Gland Identification During Total Thyroidectomy.
PubMed 文献 · J Am Coll Surg · 2019-01-31

该随机对照试验将170例全甲状腺切除术患者按1:1分组,比较近红外光(NIRL)自体荧光与白光(WL)识别甲状旁腺的效果。结果显示NIRL组术前识别甲状旁腺数从2.6增至3.5(p<0.001),67.1%患者发现至少1枚先前遗漏的腺体,且血钙≤7.5 mg/dL发生率显著降低(p=0.005)。

要点

  • NIRL可提高甲状旁腺术中识别数量,平均从2.6枚增至3.5枚。
  • NIRL组术后血钙≤7.5 mg/dL的发生率仅为白光组的十分之一。
  • 甲状腺重量每增加5g,低钙血症调整后比值比增加15%。

核心结论

  • 使用NIRL可增加甲状腺切除术中甲状旁腺的识别,并降低术后低钙血症发生率。

研究设计与样本

  • 随机对照试验,170例全甲状腺切除术患者按1:1区组随机分为NIRL组和WL组。

主要发现

  • NIRL术前识别甲状旁腺平均3.5枚,与WL术后识别3.6枚相当。
  • 实验组从WL转换为NIRL后,识别腺体数从2.6增至3.5(p<0.001),67.1%患者发现至少1枚先前遗漏腺体。
  • NIRL组血钙≤7.5 mg/dL的发生率为白光组的十分之一(p=0.005)。
  • 甲状腺重量每增加5g,低钙血症调整后比值比增加15%(OR 1.15;95%CI 1.06-1.25)。
  • 所有低钙血症均在6个月内缓解。

临床怎么用

  • 全甲状腺切除术中可考虑使用NIRL自体荧光辅助甲状旁腺识别,以减少术后低钙血症。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Parathyroid glands are difficult to identify during total thyroidectomies, and accidental resection can lead to problematic postoperative hypocalcemia. Our main goals were to evaluate the effectiveness of using near-infrared light (NIRL) autofluorescence intraoperatively for parathyroid gland identification and to measure its impact on postoperative hypocalcemia incidence. STUDY DESIGN: Total thyroidectomies were performed on 170 patients with different thyroid pathologies, block-randomized (1:1) into 2 equal groups. Among controls, traditional overhead white light (WL) was used throughout. In the experimental group, NIRL was used to enhance parathyroid gland recognition before thyroid dissection. The number of parathyroid glands identified was compared after thyroid dissection in controls using WL vs pre-dissection in the experimental using NIRL and with WL vs NIRL before thyroid dissection in the experimental group. Postoperative serum calcium levels and hypocalcemia rates were compared. RESULTS: The mean number of parathyroid glands identified pre-dissection with NIRL was the same identified post-dissection with WL (3.5 vs 3.6). In the experimental group, converting from WL to NIRL increased the number of glands detected from 2.6 to 3.5 (p < 0.001), and revealed at least 1 previously missed gland in 67.1% of patients. Calcium levels ≤7.5 mg/dL were one-tenth as common in the NIRL group (p = 0.005). The adjusted odds of hypocalcemia developing increased by 15% for every 5-g increase in thyroid gland weight (odds ratio 1.15; 95% CI 1.06 to 1.25). All hypocalcemia resolved within 6 months. CONCLUSIONS: Using NIRL during thyroidectomy increases intraoperative identification of parathyroid glands, enhances their detection before thyroid dissection, and decreases the incidence of postoperative hypocalcemia.

来源:J Am Coll Surg,查看原文。版权归原作者所有。

引用

  1. Dip F, Falco J, Verna S, et al. Randomized Controlled Trial Comparing White Light with Near-Infrared Autofluorescence for Parathyroid Gland Identification During Total Thyroidectomy. J Am Coll Surg. 2019. PMID: 30710614. doi:10.1016/j.jamcollsurg.2018.12.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。