文献速递胃肠外科

结直肠癌吻合术中近红外荧光成像与吻合口漏血清标志物的临床初步研究

Near-infrared fluorescence image-guidance in anastomotic colorectal cancer surgery and its relation to serum markers of anastomotic leakage: a clinical pilot study.
PubMed 文献 · Surg Endosc · 2019-02-01

5例(16.7%)发生吻合口漏,吻合口漏患者最大荧光评分较少出现(P=0.02)且首次评估时荧光强度低于背景(P=0.039),但荧光强度与术后CRP、I-FABP、钙卫蛋白等炎症标志物未见关联。

要点

  • 主观与客观荧光强度均可能与吻合口漏相关。
  • 吻合口漏患者最大荧光评分较少出现且首次评估荧光强度较低。
  • 荧光强度与术后炎症血清标志物尚未发现关联。

核心结论

  • 主观和测量的荧光强度似乎均与吻合口漏相关。
  • 本研究尚未发现荧光强度与炎症血清标志物之间的关联。

研究设计与样本

  • 术中三个时间点(肠管去血管化后、实际横断前、吻合完成后)静脉注射0.2 mg/kg吲哚菁绿评估肠管灌注。
  • 荧光强度按1-5分由术者主观评分,并术后用OsiriX软件测量记录视频中的荧光强度。
  • 术前及术后第1、3、5天测定血清CRP、I-FABP和钙卫蛋白,并记录吻合口漏发生情况。

主要发现

  • 手术指征包括直肠癌10例、直肠乙状结肠癌2例、乙状结肠癌10例、更近端结肠癌8例。
  • 5例(16.7%)发生吻合口漏,其中2例(6.6%)为国际直肠癌研究组定义的C级。
  • 吻合口漏患者最大荧光评分较少出现(P=0.02),且首次评估时测得荧光强度低于背景荧光强度(P=0.039)。
  • 荧光强度与术后炎症参数之间未发现关联。

临床怎么用

  • 近红外荧光成像可用于术中评估肠管灌注,荧光强度偏低可能提示吻合口漏风险。
  • 荧光强度与术后炎症血清标志物的关系尚不明确,不能替代现有监测手段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Near-infrared fluorescence (NIRF) imaging using indocyanine green (ICG) might help reduce anastomotic leakage (AL) after colorectal surgery. This pilot study aims to analyze whether a relation exists between measured fluorescence intensity (FI) and postoperative inflammatory markers of AL, C-reactive protein (CRP), Intestinal fatty-acid binding protein (I-FABP), and calprotectin, to AL, in order to evaluate the potential of FI to objectively predict AL. METHODS: Patients scheduled for anastomotic colorectal cancer surgery were eligible for inclusion in this prospective pilot study. During surgery, at three time points (after bowel devascularization; before actual transection; after completion of anastomosis) a bolus of 0.2 mg/kg ICG was administered intravenously for assessment of bowel perfusion. FI was scored in scale from 1 to 5 based on the operating surgeon's judgment (1 = no fluorescence visible, 5 = maximum fluorescent signal). The complete surgical procedure was digitally recorded. These recordings were used to measure FI postoperatively using OsiriX imaging software. Serum CRP, I-FABP, and calprotectin values were determined before surgery and on day 1, 3, and 5 postoperative; furthermore, the occurrence of AL was recorded. RESULTS: Thirty patients (n = 19 males; mean age 67 years; mean BMI 27.2) undergoing either laparoscopic or robotic anastomotic colorectal surgery were included. Indication for surgery was rectal-(n = 10), rectosigmoid-(n = 2), sigmoid-(n = 10), or more proximal colon carcinomas (n = 8). Five patients (16.7%) developed AL (n = 2 (6.6%) grade C according to the definition of the International Study group of Rectal Cancer). In patients with AL, the maximum fluorescence score was given less often (P = 0.02) and a lower FI compared to background FI was measured at 1st assessment (P = 0.039). However, no relation between FI and postoperative inflammatory parameters could be found. CONCLUSION: Both subjective and measured FI seem to be related to AL. In this study, no relation between FI and inflammatory serum markers could yet be found.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. van den Bos J, Jongen ACHM, Melenhorst J, et al. Near-infrared fluorescence image-guidance in anastomotic colorectal cancer surgery and its relation to serum markers of anastomotic leakage: a clinical pilot study. Surg Endosc. 2019. PMID: 30710314. doi:10.1007/s00464-019-06673-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。