无标记实时甲状旁腺识别的新型手术导航技术
该研究在41例甲状腺或甲状旁腺手术患者中测试了PTeye光纤探头、Overlay组织成像系统及改良近红外成像系统。PTeye在手术室照明开启条件下可实时识别98%的甲状旁腺,近红外成像系统与Overlay系统分别识别100%和97%。这些无标记技术可作为术中识别甲状旁腺的辅助手段。
要点
- PTeye可在手术室灯光开启时实时识别98%的甲状旁腺
- 近红外成像系统识别率达100%,Overlay系统为97%
- 健康与病变甲状旁腺的近红外自发荧光未见明显差异
核心结论
- PTeye可在手术室环境光下实时引导甲状旁腺识别,近红外成像系统敏感性高,Overlay系统无需显示器即可在术野内增强甲状旁腺可视化。
- 这些无标记技术可作为术中识别甲状旁腺的有价值辅助手段。
研究设计与样本
- PTeye在20例患者中测试,Overlay Tissue Imaging System在15例患者中测试,改良近红外成像系统在6例患者中研究。
- 全部41例患者均接受甲状腺切除术或甲状旁腺切除术,系统准确性以术者对原位甲状旁腺的视觉确认及切除标本组织学为参照。
主要发现
- 健康与病变甲状旁腺的近红外自发荧光之间未见可观察差异。
- PTeye识别98%的甲状旁腺,近红外成像系统识别100%,Overlay Tissue Imaging System识别97%。
临床怎么用
- PTeye可在手术室照明不关闭的条件下实时辅助甲状旁腺定位,Overlay系统可直接在术野内投射可见光标记甲状旁腺位置。
- 上述无标记技术可作为甲状腺或甲状旁腺手术中识别甲状旁腺的辅助工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Difficulty in identifying the parathyroid gland during neck operations can lead to accidental parathyroid gland excisions and postsurgical hypocalcemia. A clinical prototype called as PTeye was developed to guide parathyroid gland identification using a fiber-optic probe that detects near-infrared autofluorescence from parathyroid glands as operating room lights remain on. An Overlay Tissue Imaging System was designed concurrently to detect near-infrared autofluorescence and project visible light precisely onto parathyroid gland location. METHODS: The PTeye and the Overlay Tissue Imaging System were tested in 20 and 15 patients, respectively, and a modified near-infrared imaging system was investigated in 6 patients. All 41 patients underwent thyroidectomy or parathyroidectomy. System accuracy was ascertained with surgeon's visual confirmation for in situ parathyroid glands and histology for excised parathyroid glands. RESULTS: There was no observable difference between near-infrared autofluorescence of healthy and diseased parathyroid glands. The PTeye identified 98% of the parathyroid gland, whereas the near-infrared imaging system and the Overlay Tissue Imaging System identified 100% and 97% of the parathyroid glands, respectively. CONCLUSION: The PTeye can guide in real-time parathyroid gland identification even with ambient operating room lights. The near-infrared imaging system performs parathyroid gland imaging with high sensitivity, whereas the Overlay Tissue Imaging System enhances parathyroid gland visualization directly within the surgical field without requiring display monitors. These label-free technologies can be valuable adjuncts for identifying parathyroid glands intraoperatively.
引用
- Thomas G, McWade MA, Nguyen JQ, et al. Innovative surgical guidance for label-free real-time parathyroid identification. Surgery. 2018. PMID: 30442424. doi:10.1016/j.surg.2018.04.079
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。