文献速递疝与腹壁外科胃肠外科围术期管理与 ERAS

随机研究:新型三维头戴显示(HMS-3000MT)与二维成像对腹腔镜腹股沟疝修补术操作表现的影响

Randomized study of the influence of two-dimensional versus three-dimensional imaging using a novel 3D head-mounted display (HMS-3000MT) on performance of laparoscopic inguinal hernia repair.
PubMed 文献 · Surg Endosc · 2018-05-17

本研究将症状性腹股沟疝患者随机分配至头戴式3D显示或常规2D腹腔镜疝修补组,比较补片放置与腹膜缝合时间。结果显示3D显示可缩短经验丰富与新手外科医生的补片放置及腹膜缝合时间,并在深度感知、图像清晰度和对比度上优于2D,但外科医生舒适度显著受损,尤以耳部不适为著。

要点

  • 头戴式3D显示可缩短腹腔镜腹股沟疝修补中补片放置和腹膜缝合时间。
  • 3D在深度感知、图像清晰度和对比度上显著优于2D。
  • 3D组外科医生舒适度显著受损,耳部不适最明显。

核心结论

  • 头戴式3D显示系统在腹腔镜腹股沟疝修补的手术操作表现、深度感知和图像质量方面均优于2D。

研究设计与样本

  • 随机对照试验,将症状性腹股沟疝患者随机分配至头戴式3D显示组或常规2D腹腔镜组。
  • 比较两组补片放置时间和腹膜缝合时间,并评估图像质量和身体不适。
  • 同时纳入腹腔镜技术先进的外科医生和新手进行考察。

主要发现

  • 头戴式3D显示缩短了补片放置和腹膜缝合时间,对经验丰富和新手外科医生均如此。
  • 3D腹腔镜在深度感知、图像清晰度和图像对比度方面显著优于2D。
  • 3D腹腔镜未检测到鬼影效应所致加重的损伤。
  • 图像质量评价与腹腔镜手术经验无关。
  • 头戴式3D显示导致外科医生舒适度显著受损,最大不适来自耳部。

临床怎么用

  • 在腹腔镜腹股沟疝修补中可考虑使用头戴式3D显示以缩短关键操作时间并改善图像质量。
  • 使用时需关注外科医生舒适度,尤其是耳部不适。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: 3D laparoscopy has proven to be superior to the 2D approach in experimental settings. The aim of the present study was to investigate the influence of 3D laparoscopy using a novel head-mounted display on the performance of defined steps within a laparoscopic inguinal hernia repair. This effect was investigated both in laparoscopically advanced surgeons and in beginners. METHODS: Patients suffering from symptomatic inguinal hernia were randomly assigned to laparoscopic hernia repair using either a head-mounted 3D display or a conventional 2D laparoscopic approach. Operative performance of both groups was compared in terms of the time taken for mesh placement and for peritoneal suturing. Additionally, quality of imaging and physical discomfort were assessed. RESULTS: The use of a head-mounted 3D display was able to shorten the time required for placement of the mesh as well as that for peritoneal suturing, both for experienced and novice surgeons when compared to the conventional 2D approach. 3D laparoscopy was significantly superior to 2D laparoscopy in terms of depth perception, image sharpness and image contrast. Additionally, increased impairment caused by ghosting effects could not be detected in 3D laparoscopy. Evaluation of image quality was independent of experience in laparoscopic surgery. However, use of a head-mounted 3D display resulted in a significant impairment of surgeon's comfort when compared to 2D laparoscopy. Thereby, the greatest impairment was caused by ear discomfort. CONCLUSIONS: This is the first study examining the effect of a head-mounted 3D system on the performance of laparoscopy in a randomized controlled trial (RCT) showing a clear advantage of this system in surgical performance as well as in depth perception and image quality.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Patrzyk M, Klee M, Stefaniak T, et al. Randomized study of the influence of two-dimensional versus three-dimensional imaging using a novel 3D head-mounted display (HMS-3000MT) on performance of laparoscopic inguinal hernia repair. Surg Endosc. 2018. PMID: 29777354. doi:10.1007/s00464-018-6215-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。