文献速递胃肠外科围术期管理与 ERAS

低位腹腔内压对腹腔镜结直肠手术无心肺益处:双盲随机对照试验

Lower intra-abdominal pressure has no cardiopulmonary benefits during laparoscopic colorectal surgery: a double-blind, randomized controlled trial.
PubMed 文献 · Surg Endosc · 2018-05-14

该双盲随机对照试验将腹腔镜结直肠手术患者随机分为低压(8 mmHg)深阻滞组、标准压(12 mmHg)深阻滞组和标准压中度阻滞组,主要结局为腹腔镜开始后30分钟的心脏指数。结果显示三组心脏指数无差异(P=0.715),低压组肺顺应性更高但手术条件更差(均P<0.001),结论认为标准压可能优于低压。

要点

  • 低压(8 mmHg)与标准压(12 mmHg)相比,腹腔镜开始后30分钟心脏指数无差异。
  • 低压组肺顺应性更高,但手术条件更差,两者差异均有统计学意义。
  • 综合心肺动力学与手术条件,腹腔镜手术可能更适合采用标准腹腔内压。

核心结论

  • 低压腹腔内压 during 腹腔镜结直肠手术未显示心肺益处,且手术条件更差,标准压可能更可取。

研究设计与样本

  • 双盲随机对照试验,将腹腔镜结直肠手术患者按腹腔内压和神经肌肉阻滞水平随机分组:低压(8 mmHg)深阻滞组(n=44)、标准压(12 mmHg)深阻滞组(n=44)、标准压中度阻滞组(n=43)。
  • 主要结局为腹腔镜开始后30分钟的心脏指数。

主要发现

  • 腹腔镜开始后30分钟心脏指数均值(SD)在三组分别为2.7(0.7)、2.7(0.9)、2.6(1.0)L min-1 m-2(P=0.715)。
  • 低压组肺顺应性高于标准压组,但手术条件差于标准压组(均P<0.001)。
  • 其他变量组间相当。

临床怎么用

  • 在腹腔镜结直肠手术中,综合考虑心肺动力学和手术条件,标准腹腔内压可能优于低压。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Higher intra-abdominal pressure may impair cardiopulmonary functions during laparoscopic surgery. While 12-15 mmHg is generally recommended as a standard pressure, the benefits of lower intra-abdominal pressure are unclear. We thus studied whether the low intra-abdominal pressure compared with the standard pressure improves cardiopulmonary dynamics during laparoscopic surgery. METHODS: Patients were randomized according to the intra-abdominal pressure and neuromuscular blocking levels during laparoscopic colorectal surgery: low pressure (8 mmHg) with deep-block (post-tetanic count 1-2), standard pressure (12 mmHg) with deep-block, and standard pressure with moderate-block (train-of-four count 1-2) groups. During the laparoscopic procedure, we recorded cardiopulmonary variables including cardiac index, pulmonary compliance, and surgical conditions. We also assessed postoperative pain intensity and recovery time of bowel movement. The primary outcome was the cardiac index 30 min after onset of laparoscopy. RESULTS: Patients were included in the low pressure with deep-block (n = 44), standard pressure with deep-block (n = 44), and standard pressure with moderate-block (n = 43) groups. The mean (SD) of cardiac index 30 min after laparoscopy was 2.7 (0.7), 2.7 (0.9), and 2.6 (1.0) L min-1 m-2 in each group (P = 0.715). The pulmonary compliance was higher but the surgical condition was poorer in the low intra-abdominal pressure than the standard pressure (both P < 0.001). Other variables were comparable between groups. CONCLUSION: We observed few cardiopulmonary benefits but poor surgical conditions in the low intra-abdominal pressure during laparoscopy. Considering cardiopulmonary dynamics and surgical conditions, the standard intra-abdominal pressure may be preferable to the low pressure for laparoscopic surgery.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Cho YJ, Paik H, Jeong SY, et al. Lower intra-abdominal pressure has no cardiopulmonary benefits during laparoscopic colorectal surgery: a double-blind, randomized controlled trial. Surg Endosc. 2018. PMID: 29761274. doi:10.1007/s00464-018-6204-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。