文献速递胃肠外科围术期管理与 ERAS

亚甲蓝荧光在结直肠手术中输尿管定位的原理验证研究

Methylene blue fluorescence of the ureter during colorectal surgery.
PubMed 文献 · Surg Endosc · 2018-05-21

这项开放标签非随机原理验证研究纳入择期结直肠手术患者,静脉给予亚甲蓝(0.25-1 mg/kg)后使用PINPOINT深红腹腔镜系统评估输尿管荧光显影。42例患者中69条输尿管有64条在荧光下可见,其中14条白光下不可见,10例荧光显示输尿管位置与预期不同。亚甲蓝荧光是输尿管定位的有前景方法。

要点

  • 亚甲蓝荧光可显示白光下不可见的输尿管,提高术中定位安全性
  • 荧光可更早识别输尿管,并纠正对输尿管位置的错误判断
  • 本研究为原理验证,样本量小且非随机,需进一步验证

核心结论

  • 亚甲蓝荧光是结直肠手术中输尿管定位的有前景方法,可改善标准术野下难以识别输尿管的可视化。

研究设计与样本

  • 开放标签、非随机原理验证研究,纳入择期结直肠手术患者42例接受亚甲蓝,2例排除分析。
  • 亚甲蓝静脉给药剂量0.25-1 mg/kg,输注5分钟,于进入输尿管区域前10-15分钟给予。
  • 使用PINPOINT深红腹腔镜系统,由术者和独立观察者在固定时间点评估荧光。

主要发现

  • 42例患者接受亚甲蓝,2例排除分析;共评估69条输尿管,64条在荧光下可见。
  • 荧光下可见的64条输尿管中,14条在白光下不可见。
  • 50条输尿管同时经荧光和白光观察,其中14条经荧光更早被识别。
  • 10例中荧光显示输尿管位置与术前怀疑位置不同。

临床怎么用

  • 在结直肠手术进入输尿管区域前10-15分钟静脉给予亚甲蓝0.25-1 mg/kg,配合PINPOINT深红系统辅助输尿管定位。
  • 对白光下难以识别的输尿管,可借助亚甲蓝荧光提高可视化并核对位置。

局限性

  • 本研究为开放标签、非随机、小样本原理验证研究,结果需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Iatrogenic ureteric injury is a serious complication of colorectal surgery. Incidence is estimated to be between 0.3 and 1.5%. Of all ureteric injuries, 9% occur during colorectal procedures. Ureteric stents are utilised as a method to reduce the risk of injury; however, these are not without risk and do not guarantee prevention of injury. Fluorescence is a safe and effective alternative for intraoperative ureteric localisation. This proof of principle study aims to assess the use of methylene blue to fluoresce the ureter during colorectal surgery. METHOD: Patients undergoing elective colorectal surgery were included in this open label, non-randomised study. Methylene blue was administered intravenously at varying doses (0.25-1 mg/kg) over 5 min, 10-15 min prior to entering 'ureteric territory.' Fluorescence was assessed using the PINPOINT Deep Red laparoscopic system at fixed time points by the surgeon and an independent observer. RESULTS: 42 patients received methylene blue; 2 patients were excluded from analysis. Of the 69 ureters assessed, 64 were seen under fluorescence. Of these, 14 were not visible under white light. 50 ureters were observed with both fluorescence and white light with 14 of these being seen earlier with fluorescence. In ten cases, fluorescence revealed the ureter to be in a different location than suspected. CONCLUSION: Fluorescence is a promising method to allow visualisation of the ureter, where it is not identified easily under standard operative conditions, thereby improving safety and reducing operative time and difficulty.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Barnes TG, Hompes R, Birks J, et al. Methylene blue fluorescence of the ureter during colorectal surgery. Surg Endosc. 2018. PMID: 29785456. doi:10.1007/s00464-018-6219-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。