磁共振弹性成像肝硬度值预测肝切除术后重大并发症
这项前瞻性研究纳入2013年4月至2016年8月连续96例肝切除患者,术前用磁共振弹性成像(MRE)测肝硬度(LS)。主要终点为Clavien-Dindo IIIa级及以上重大并发症,发生15例(16%)。多因素分析显示较高LS值(P=0·021)和血清白蛋白水平(P=0·009)为独立预测因素;LS最佳截断值4·3 kPa,灵敏度80%、特异度82%,联合白蛋白的logistic模型AUC为0·84。
要点
- MRE测得的肝硬度值是肝切除术后重大并发症的独立预测因素。
- LS最佳截断值4·3 kPa对应F4级肝纤维化,灵敏度80%、特异度82%。
- 联合LS值与血清白蛋白的模型预测重大并发症AUC达0·84。
核心结论
- 肝切除患者术前MRE测定的肝硬度值是术后重大并发症的独立预测因素。
研究设计与样本
- 前瞻性研究,连续纳入2013年4月至2016年8月接受肝切除的患者96例,术前用MRE测量肝硬度值。
主要发现
- 96例中15例(16%)发生Clavien-Dindo IIIa级及以上重大并发症。
- 多因素logistic分析确认较高LS值(P=0·021)和血清白蛋白水平(P=0·009)为重大并发症的独立预测因素。
- ROC分析显示LS最佳截断值为4·3 kPa,对应肝纤维化F4级,灵敏度80%、特异度82%。
- 联合LS值与血清白蛋白的logistic模型预测重大并发症的AUC为0·84。
关键数值与推荐
- 重大并发症定义为Clavien-Dindo分级IIIa级或以上。
- LS预测重大并发症的最佳截断值为4·3 kPa,灵敏度80%、特异度82%,与肝纤维化F4级相当。
临床怎么用
- 术前可用MRE无创测定肝硬度值,结合血清白蛋白水平评估肝切除术后重大并发症风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Liver fibrosis is a risk factor for hepatectomy but cannot be determined accurately before hepatectomy because diagnostic procedures are too invasive. Magnetic resonance elastography (MRE) can determine liver stiffness (LS), a surrogate marker for assessing liver fibrosis, non-invasively. The aim of this study was to investigate whether the LS value determined by MRE is predictive of major complications after hepatectomy. METHODS: This prospective study enrolled consecutive patients who underwent hepatic resection between April 2013 and August 2016. LS values were measured by imaging shear waves by MRE in the liver before hepatectomy. The primary endpoint was major complications, defined as Clavien-Dindo grade IIIa or above. Logistic regression analysis identified independent predictive factors, from which a logistic model to estimate the probability of major complications was constructed. RESULTS: A total of 96 patients were included in the study. Major complications were observed in 15 patients (16 per cent). Multivariable logistic analysis confirmed that higher LS value (P = 0·021) and serum albumin level (P = 0·009) were independent predictive factors for major complications after hepatectomy. Receiver operating characteristic (ROC) analysis showed that the best LS cut-off value was 4·3 kPa for detecting major complications, comparable to liver fibrosis grade F4, with a sensitivity of 80 per cent and specificity of 82 per cent. A logistic model using the LS value and serum albumin level to estimate the probability of major complications was constructed; the area under the ROC curve for predicting major complications was 0·84. CONCLUSION: The LS value determined by MRE in patients undergoing hepatectomy was an independent predictive factor for major complications.
引用
- Sato N, Kenjo A, Kimura T, et al. Prediction of major complications after hepatectomy using liver stiffness values determined by magnetic resonance elastography. Br J Surg. 2018. PMID: 29683188. doi:10.1002/bjs.10831
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。