文献速递胃肠外科围术期管理与 ERAS

结直肠手术腹腔镜安全抓取阈值的活体分析

An in vivo analysis of safe laparoscopic grasping thresholds for colorectal surgery.
PubMed 文献 · Surg Endosc · 2018-03-30

本研究使用仪器化腹腔镜抓钳对猪结肠施加不同力度和时长的抓取,通过组织学分析探讨机械压力与组织损伤的关系。研究发现50N及以上力度在所有抓取时长下均引起显著肌肉面积差异,纵向肌肉在较低力度和时长下也出现显著变化,组织学改变与力-时间乘积超过300 N·s相关。

要点

  • 50N及以上抓取力在所有时长下均导致结肠纵行肌和环行肌显著组织学改变。
  • 纵向肌肉在20N持续30秒或60秒、40N持续30秒时即出现显著肌肉面积差异。
  • 组织学改变与力-时间乘积超过300 N·s相关,提示累积力是损伤因素。

核心结论

  • 腹腔镜抓取结肠时,50N及以上力度在所有抓取时长下均引起显著组织学改变。
  • 纵向肌肉在较低力度(20N)和较短时长(30秒)下即可出现显著肌肉面积差异。
  • 组织学改变与力-时间乘积超过300 N·s相关,提示累积力是损伤因素。

研究设计与样本

  • 活体猪结肠实验,使用仪器化腹腔镜抓钳测量施加的力并绘制力-时间曲线。
  • 对施加10、20、40、50和70N力度持续5、30和60秒的组织进行HE染色组织学分析。
  • 比较抓取与未抓取区域结肠环行肌和纵行肌的面积,计算力-时间乘积(FTP)。

主要发现

  • FTP范围为55.7至3793 N·s。
  • 50N及以上力度在所有抓取时长下,抓取与未抓取区域的纵行肌和环行肌面积均存在显著差异。
  • 纵向肌肉在20N持续30秒时平均差异59 mm2(95%CI 41-77 mm2,P=0.04)。
  • 纵向肌肉在20N持续60秒时平均差异31 mm2(95%CI 21.5-40.5 mm2,P=0.006)。
  • 纵向肌肉在40N持续30秒时平均差异37 mm2(95%CI 27-47 mm2,P=0.006)。

临床怎么用

  • 腹腔镜结直肠手术中应避免抓取力达到50N及以上,以减少结肠组织学损伤。
  • 需关注累积抓取力,力-时间乘积超过300 N·s与纵向肌肉组织学改变相关。
  • 研究结果可为开发具有主动约束功能的智能腹腔镜抓钳提供依据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Analysis of safe laparoscopic grasping thresholds for the colon has not been performed. This study aimed to analyse tissue damage thresholds when the colon is grasped laparoscopically, correlating histological changes to mechanical compressive forces. METHODS: An instrumented laparoscopic grasper was used to measure the forces applied to porcine colon, with data captured and plotted as a force-time (f-t) curve. Haematoxylin and eosin histochemistry of tissue subjected to 10, 20, 40, 50 and 70 N for 5, 30 and 60 s was performed, and the area of colonic circular and longitudinal muscle was compared in grasped and un-grasped regions. The area under the f-t curve was calculated as a measure of the accumulated force applied, known as the force-time product (FTP). RESULTS: FTP ranged from 55.7 to 3793 N.s. Significant differences were observed between the muscle area of the grasped and un-grasped regions in both longitudinal and circular muscle at 50 N and above for all grasping times. For the longitudinal muscle, significant differences were observed between grasped and un-grasped areas at 20 N force for 30 s (mean difference = 59 mm2, 95% CI 41-77 mm2, P = 0.04), 20 N force for 60 s (mean difference = 31 mm2, 95% CI 21.5-40.5 mm2, P = 0.006) and 40 N force for 30 s (mean difference 37 mm2, 95% CI 27-47 mm2, P = 0.006). Changes in histology correlated with mechanical forces applied to the longitudinal muscle at a FTP over 300 N s. CONCLUSIONS: This study characterizes the grasping forces that result in histological changes to the colon and correlates these with a mechanical measurement of the applied force. The findings will contribute to the development of smart laparoscopic graspers with active constraints to prevent excessive grasping and tissue injury.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Barrie J, Russell L, Hood AJ, et al. An in vivo analysis of safe laparoscopic grasping thresholds for colorectal surgery. Surg Endosc. 2018. PMID: 29602989. doi:10.1007/s00464-018-6172-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。