磁性括约肌增强联合食管裂孔修补术后的疝复发中期结局
平均随访19个月,GERD-HRQL评分从20.3降至3.1(p<.001),89%停用PPI,97%症状改善或缓解。2例复发,复发率4.3%,13%出现持续性吞咽困难。
要点
- MSA联合食管裂孔疝修补术后中期疝复发率4.3%,GERD症状控制持久。
- 89%患者停用PPI,GERD-HRQL评分显著改善。
- 13%出现持续性吞咽困难,多数经单次球囊扩张缓解。
核心结论
- 对于胃食管反流病合并中等大小食管裂孔疝的患者,同期行MSA和疝修补在1-2年随访中显示出持久的症状性反流控制和可接受的疝复发率。
主要发现
- 食管裂孔疝大小3-7cm(平均4±1cm),平均临床随访19个月(范围1-39个月)。
- GERD-HRQL评分从20.3降至3.1(p<.001),89%患者停用PPI,97%报告症状改善或缓解。
- 监测影像发现2例复发疝,复发率4.3%,平均复发时间18±10个月。
- 13%(6/47)出现持续性吞咽困难,其中67%(4/6)经单次球囊扩张缓解;2例因扩张难治性吞咽困难和持续反流症状取出装置。
临床怎么用
- 对于胃食管反流病合并中等大小食管裂孔疝(≥3cm)的患者,可考虑同期行MSA和疝修补术。
- 术后需监测疝复发, routine 影像学检查可发现无症状复发。
- 持续性吞咽困难常见,多数可通过球囊扩张缓解,少数需取出装置。
局限性
- 回顾性研究,样本量较小(47例),随访时间中等(平均19个月)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We have previously reported short-term outcomes after hiatal hernia repair (HHR) at the time of magnetic sphincter augmentation (MSA) for gastroesophageal reflux disease (GERD). Here we report intermediate-term outcomes and hernia recurrence rate after concomitant MSA and HHR. METHODS: This is a retrospective cohort study of patients who underwent repair of a hiatal hernia 3 cm or larger at the time of MSA implantation between May 2009 and December 2015. The primary endpoint was hiatal hernia recurrence identified by routine postoperative videoesophagography or endoscopy. Recurrence was defined by a 2 cm or greater upward displacement of the stomach through the diaphragmatic esophageal hiatus. Secondary endpoints included cessation of proton-pump inhibitor (PPI), persistent dysphagia requiring intervention, and GERD health-related quality-of-life (HRQL) scores 1 year from surgery. RESULTS: During the study period, 47 of 53 (89%) patients underwent concomitant MSA with HHR and complied with surveillance. Hiatal hernias ranged from 3 to 7 cm (mean 4 ± 1). Mean clinical follow-up time was 19 months (range 1-39). GERD-HRQL score decreased from 20.3 to 3.1 (p < .001), 89% of patients remained off PPIs, and 97% of patients reported improvement or resolution of symptoms. Two recurrent hiatal hernias were identified on surveillance imaging for a recurrence rate of 4.3% at a mean 18 (± 10) months after initial operation. Persistent dysphagia occurred in 13% (6/47) over the first year, which resolved after a single balloon dilation in 67% (4/6). Two patients elected for device removal due to dilation-refractory dysphagia and persistent reflux symptoms. CONCLUSION: Concomitant magnetic sphincter augmentation and hiatal hernia repair in patients with gastroesophageal reflux disease and a moderate-sized hiatal hernia demonstrates durable subjective reflux control and an acceptable hiatal hernia recurrence rate at 1- to 2-year follow-up.
引用
- Rona KA, Tatum JM, Zehetner J, et al. Hiatal hernia recurrence following magnetic sphincter augmentation and posterior cruroplasty: intermediate-term outcomes. Surg Endosc. 2018. PMID: 29340828. doi:10.1007/s00464-018-6059-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。