文献速递胃肠外科围术期管理与 ERAS

新型全覆膜双凸起支架治疗减重术后吻合口漏的回顾性分析

A novel fully covered double-bump stent for staple line leaks after bariatric surgery: a retrospective analysis.
PubMed 文献 · Surg Endosc · 2018-01-17

这项回顾性研究在三个高容量减重中心纳入2009至2016年间因吻合口漏置入Niti-S Beta支架的连续患者,评估其有效性和不良事件率。支架移位发生12例(32%),尽管采用双凸起结构,移位率似乎并未降低。

要点

  • Beta支架治疗减重术后吻合口漏的总愈合率为66%。
  • 初次治疗者愈合率100%,修正手术失败后补救者仅55%。
  • 支架移位率32%,双凸起设计未显示降低移位。

核心结论

  • Beta支架的愈合率和移位率在本回顾性研究中与其他支架相当。
  • 尽管具有新型双凸起结构,移位率似乎并未降低。

研究设计与样本

  • 回顾性研究,在三个高容量减重中心进行。

主要发现

  • 初次治疗者愈合率为100%,修正手术失败后置入者愈合率为55%(p=0.013)。
  • 移位发生12例(32%)。
  • 发生两例需手术干预的严重不良事件,包括一例主动脉-食管瘘出血。

关键数值与推荐

  • 主要结局为漏口愈合,次要结局为包括移位在内的不良事件率。

临床怎么用

  • 对于减重术后吻合口漏,可考虑置入Beta支架,但需注意移位风险。
  • 初次治疗时使用Beta支架愈合率较高,修正手术失败后补救性置入愈合率较低。

局限性

  • 回顾性研究设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Staple line leakage after bariatric surgery can be treated by endoscopic placement of a self-expandable stent. The success rate of stent placement is generally high, but migration is a frequent adverse event that hampers successful treatment. The Niti-S Beta stent is a fully covered double-bump stent that was specifically designed to prevent migration. This study aimed to evaluate the effectiveness and adverse event rate of the Niti-S Beta stent. METHODS: A retrospective study was performed in three high-volume bariatric centers. All consecutive patients between 2009 and 2016 who underwent placement of a Beta stent for staple line leakage were included. Primary outcome was resolution of the leakage; secondary outcome was the adverse event rate including migration. RESULTS: Thirty-eight patients were included. Twenty-five (66%) had resolution of the leakage. Success rate was higher in patients who were treated with implantation of a Beta stent as initial treatment (100%) than in patients who were treated with a stent after revisional surgery had failed (55%, p = 0.013). Migration occurred in 12 patients (32%). There were two severe adverse events requiring surgical intervention, including a bleeding from an aorto-esophageal fistula. CONCLUSIONS: The success rate and the migration rate of the Beta stent seem comparable to other stents in this retrospective study. Despite the novel double-bump structure of the stent, the migration rate does not seem to be decreased.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Boerlage TCC, Houben GPM, Groenen MJM, et al. A novel fully covered double-bump stent for staple line leaks after bariatric surgery: a retrospective analysis. Surg Endosc. 2018. PMID: 29344787. doi:10.1007/s00464-018-6034-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。