文献速递疝与腹壁外科

腹腔镜腹壁疝修补术后氧化铁负载PVDF补片MRI收缩的前瞻性队列研究

Prospective cohort study on mesh shrinkage measured with MRI after laparoscopic ventral hernia repair with an intraperitoneal iron oxide-loaded PVDF mesh.
PubMed 文献 · Surg Endosc · 2017-12-21

本研究利用MRI可视化铁颗粒增强的腹腔内PVDF补片,前瞻性测量腹腔镜腹壁疝修补术后1至13个月的补片收缩情况。15例患者中13例完成两次MRI,四位放射科医师盲法独立测量。结果显示测量者间信度极佳,补片在1至13个月间宽度、长度和表面积均无显著收缩。

要点

  • MRI测量腹腔内PVDF补片尺寸的观察者间信度极佳(ICC 0.95-0.99)。
  • 补片植入后1个月内宽度和长度较植入时显著缩小。
  • 术后1至13个月补片宽度、长度和表面积均无显著收缩。

核心结论

  • 放射科医师使用MRI测量可见腹腔内PVDF补片的宽度、长度和表面积具有极佳的观察者间信度。
  • 腹腔镜腹壁疝修补术后1至13个月,腹腔内PVDF补片无显著收缩。

研究设计与样本

  • 前瞻性队列研究,共15例患者接受腹腔镜腹壁疝修补术,其中13例在术后1个月和13个月均接受MRI检查。
  • 由四位对MRI检查时间盲法的放射科医师独立采用标准化方法测量补片的宽度、长度和表面积。

主要发现

  • 观察者间信度:宽度ICC 0.95(95% CI 0.92-0.98),长度ICC 0.96(95% CI 0.93-0.98),表面积ICC 0.99(90% CI 0.99-1.00)。
  • 植入时与术后1个月MRI比较:宽度变化-0.7 cm(P=0.023;-3.6%),长度变化-1.9 cm(P=0.001;-7.2%)。
  • 术后1个月与13个月比较:宽度变化-0.06 cm(P=0.74;收缩0.3%),长度变化-0.12 cm(P=0.56;收缩0.5%),表面积变化-4.0 cm2(P=0.20;收缩1.0%)。

关键数值与推荐

  • 腹腔内PVDF补片(DynaMesh IPOM visible)在MRI下可视,可用于测量补片尺寸变化。
  • 术后1至13个月补片宽度、长度和表面积变化均无统计学显著性。

临床怎么用

  • MRI可作为评估腹腔内可见PVDF补片尺寸变化的可靠工具,观察者间信度高。
  • 腹腔镜腹壁疝修补术后1至13个月,PVDF补片未见显著收缩,提示该补片中期尺寸稳定性良好。

局限性

  • 样本量较小,仅13例患者完成两次MRI评估。
  • 随访时间为1至13个月,缺乏更长期数据。
  • 仅评估一种特定类型补片(铁颗粒增强PVDF补片)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current data on shrinkage of intraperitoneal meshes come mainly from animal studies. High-quality human data in prospective studies are scarce. METHODS: We used the ability to visualize intraperitoneal PVDF meshes enhanced with iron particles (DynaMesh IPOM visible) with magnetic resonance imaging (MRI) to determine the amount of shrinkage between 1 and 13 months postoperatively. All measurements of the width, length, and surface area of the mesh were performed with a standardized methodology independently by four radiologists blinded for the timing of the MRI. RESULTS: Of the 15 patients undergoing laparoscopic ventral hernia repair, 13 patients received an MRI both at 1 and at 13 months. Evaluation of inter-rater reliability between the radiologists showed intra-class correlations of 0.95 (95% CI 0.92-0.98) for the width, 0.96 (95% CI 0.93-0.98) for the length, and 0.99 (90% CI 0.99-1.00) for the surface area of the mesh. The change between measurement at implantation and 1-month MRI was - 0.7 cm (P = 0.023; - 3.6%) for the width and - 1.9 cm (P = 0.001; - 7.2%) for the length. The change between 1 and 13 months was - 0.06 cm (P = 0.74; shrinkage = 0.3%) for the width, - 0.12 cm (P = 0.56; shrinkage = 0.5%) for the length, and - 4.0 cm2 (P = 0.20; shrinkage = 1.0%) for the surface area of the mesh. CONCLUSION: There is excellent inter-rater reliability between radiologists when measuring width, length, and surface area of visible intraperitoneal PVDF mesh with MRI. There is no significant shrinkage between 1 and 13 months of intraperitoneal PVDF mesh after laparoscopic ventral hernia repair.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Muysoms F, Beckers R, Kyle-Leinhase I, et al. Prospective cohort study on mesh shrinkage measured with MRI after laparoscopic ventral hernia repair with an intraperitoneal iron oxide-loaded PVDF mesh. Surg Endosc. 2017. PMID: 29270800. doi:10.1007/s00464-017-5987-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。