AutoLap™系统首次体验:基于图像的机器人摄像头操控装置
两项多中心研究评估AutoLap™图像分析操控腹腔镜摄像头核心技术的安全性与效率,9名经验丰富外科医生完成66例各类腹腔镜手术,64例(97%)使用该系统完成手术,平均安装时间4分钟,超过90%的图像移动准确,无系统相关不良事件,用户满意度评分分别为3.85和3.96(1-5分)。
要点
- AutoLap™系统基于图像分析操控摄像头,64例(97%)手术使用该系统完成。
- 平均安装时间4分钟,手术时间未因使用系统而延长。
- 超过90%的图像移动准确,无系统相关不良事件,用户满意度3.85-3.96分。
核心结论
- AutoLap™系统核心技术使用安全高效,图像稳定性高,外科医生满意度良好。
研究设计与样本
- 两项多中心研究,共66例各类腹腔镜手术,由9名经验丰富的外科医生使用AutoLap™系统完成。
主要发现
- 64例(97%)手术使用AutoLap™系统完成。
- 平均总体安装时间为4分钟(04:08 ± 0.10)。
- 手术时间与文献平均值相比未因使用该系统而延长。
- 两项研究中用户满意度评分分别为3.85和3.96(1-5分)。
- 超过90%的基于图像的移动准确,使用期间无系统相关不良事件记录。
临床怎么用
- AutoLap™系统可安全用于多种腹腔镜手术,安装快捷且不延长手术时间,可作为机器人摄像头操控的替代选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Robotic camera holders for endoscopic surgery have been available for 20 years but market penetration is low. The current camera holders are controlled by voice, joystick, eyeball tracking, or head movements, and this type of steering has proven to be successful but excessive disturbance of surgical workflow has blocked widespread introduction. The Autolap™ system (MST, Israel) uses a radically different steering concept based on image analysis. This may improve acceptance by smooth, interactive, and fast steering. These two studies were conducted to prove safe and efficient performance of the core technology. METHODS: A total of 66 various laparoscopic procedures were performed with the AutoLap™ by nine experienced surgeons, in two multi-center studies; 41 cholecystectomies, 13 fundoplications including hiatal hernia repair, 4 endometriosis surgeries, 2 inguinal hernia repairs, and 6 (bilateral) salpingo-oophorectomies. The use of the AutoLap™ system was evaluated in terms of safety, image stability, setup and procedural time, accuracy of imaged-based movements, and user satisfaction. RESULTS: Surgical procedures were completed with the AutoLap™ system in 64 cases (97%). The mean overall setup time of the AutoLap™ system was 4 min (04:08 ± 0.10). Procedure times were not prolonged due to the use of the system when compared to literature average. The reported user satisfaction was 3.85 and 3.96 on a scale of 1 to 5 in two studies. More than 90% of the image-based movements were accurate. No system-related adverse events were recorded while using the system. CONCLUSION: Safe and efficient use of the core technology of the AutoLap™ system was demonstrated with high image stability and good surgeon satisfaction. The results support further clinical studies that will focus on usability, improved ergonomics and additional image-based features.
引用
- Wijsman PJM, Broeders IAMJ, Brenkman HJ, et al. First experience with THE AUTOLAP™ SYSTEM: an image-based robotic camera steering device. Surg Endosc. 2017. PMID: 29101564. doi:10.1007/s00464-017-5957-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。