文献速递肝胆胰外科

远端胰腺切除术后第1天引流液淀粉酶预测临床相关胰瘘的最佳截断值

Identification of an Optimal Cut-off for Drain Fluid Amylase on Postoperative Day 1 for Predicting Clinically Relevant Fistula After Distal Pancreatectomy: A Multi-institutional Analysis and External Validation.
PubMed 文献 · Ann Surg · 2019-01-01

本研究基于两个独立多中心远端胰腺切除(DP)队列,探讨术后第1天引流液淀粉酶(DFA1)与临床相关胰瘘(CR-POPF)的关系。开发队列338例中DFA1中位1745 U/L,CR-POPF率21.9%;验证队列166例中DFA1中位784.5 U/L,CR-POPF率10.2%。DFA1 2000 U/L在兩队列中均具有最高约登指数,多因素分析显示DFA1≥2000 U/L是唯一与CR-POPF显著相关的因素。

要点

  • DFA1 2000 U/L是预测DP后CR-POPF的最佳截断值。
  • 开发队列敏感度74.3%、特异度62.1%;验证队列敏感度64.7%、特异度75.8%。
  • DFA1≥2000 U/L在多因素分析中为唯一显著相关因素。

核心结论

  • DFA1 2000 U/L可优化远端胰腺切除术后临床相关胰瘘的预测。

研究设计与样本

  • 多中心回顾性队列研究,开发队列338例(2012-2017年),验证队列166例(2006-2016年)。

主要发现

  • 开发队列DFA1中位1745 U/L,CR-POPF率21.9%,DFA1预测CR-POPF的AUC为0.737(P<0.001)。
  • 验证队列DFA1中位784.5 U/L(P<0.001),CR-POPF率10.2%(P<0.001)。
  • DFA1 2000 U/L在开发队列敏感度74.3%、特异度62.1%,在验证队列敏感度64.7%、特异度75.8%。
  • 多因素分析中DFA1≥2000 U/L是两个队列中唯一与CR-POPF显著相关的因素。

关键数值与推荐

  • DFA1截断值2000 U/L基于约登指数最高值确定。
  • DFA1≥2000 U/L与CR-POPF显著相关(多因素分析)。

临床怎么用

  • 远端胰腺切除术后第1天可检测引流液淀粉酶,以2000 U/L为阈值识别CR-POPF高危患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this study was to investigate the relationship between drain fluid amylase value on the first postoperative day (DFA1) and clinically relevant fistula (CR-POPF) after distal pancreatectomy (DP), and to identify the cut-off of DFA1 that optimizes CR-POPF prediction. BACKGROUND: DFA1 is a well-recognized predictor of CR-POPF after pancreatoduodenectomy, but its role in DP is largely unexplored. METHODS: DFA1 levels were correlated with CR-POPF in 2 independent multi-institutional sets of DP patients: developmental (n = 338; years 2012 to 2017) and validation cohort (n = 166; years 2006 to 2016). Cut-off choice was based on Youden index calculation, and its ability to predict CR-POPF occurrence was tested in a multivariable regression model adjusted for clinical, demographic, operative, and pathological variables. RESULTS: In the developmental set, median DFA1 was 1745 U/L and the CR-POPF rate was 21.9%. DFA1 correlated with CR-POPF with an area under the curve of 0.737 (P < 0.001). A DFA1 of 2000 U/L had the highest Youden index, with 74.3% sensitivity and 62.1% specificity. Patients in the validation cohort displayed different demographic and operative characteristics, lower values of DFA1 (784.5 U/L, P < 0.001), and reduced CR-POPF rate (10.2%, P < 0.001). However, a DFA1 of 2000 U/L had the highest Youden index in this cohort as well, with 64.7% sensitivity and 75.8% specificity. At multivariable analysis, DFA1 ≥2000 U/L was the only factor significantly associated with CR-POPF in both cohorts. CONCLUSION: A DFA1 of 2000 U/L optimizes CR-POPF prediction after DP. These results provide the substrate to define best practices and improve outcomes for patients receiving DP.

来源:Ann Surg,查看原文。版权归原作者所有。

引用

  1. Maggino L, Malleo G, Bassi C, et al. Identification of an Optimal Cut-off for Drain Fluid Amylase on Postoperative Day 1 for Predicting Clinically Relevant Fistula After Distal Pancreatectomy: A Multi-institutional Analysis and External Validation. Ann Surg. 2019. PMID: 28938266. doi:10.1097/SLA.0000000000002532

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。