单极软凝设备联合肝细胞压碎法在腹腔镜肝切除中控制出血的应用
该研究回顾了2008年1月至2016年3月共150例肝细胞癌患者接受腹腔镜肝切除(LLR)的经验,其中144例为部分肝切除,6例为左肝外侧叶切除。手术采用单极软凝设备联合肝细胞压碎法(HeCM)控制出血。中位失血量30克,中位手术时间207分钟,无术中出血导致的转开腹,术后并发症发生率4.7%,无死亡。结论认为HeCM联合单极软凝设备是减少肝细胞癌患者肝切除出血的良好技术。
要点
- 单极软凝设备联合肝细胞压碎法可有效控制腹腔镜肝切除中的出血。
- 150例肝细胞癌患者中,中位失血量仅30克,无因出血中转开腹。
- 术后并发症发生率4.7%,无死亡,安全性良好。
核心结论
- HeCM联合单极软凝设备是减少肝细胞癌患者肝切除术中出血的良好技术。
研究设计与样本
- 回顾性单中心研究,2008年1月至2016年3月共纳入150例肝细胞癌患者,其中144例行部分肝切除,6例行左肝外侧叶切除。
主要发现
- 中位失血量30克(范围0-490克),中位手术时间207分钟(范围127-468分钟)。
- 1例因严重粘连中转开腹,无患者因术中出血中转开腹。
- 术后并发症7例(4.7%),包括腹腔脓肿2例、伤口感染2例、腹腔出血1例、胆管狭窄1例、脐疝1例,死亡率为零。
- 术后中位住院时间6天(范围3-21天),峰值AST中位数320 IU/L(范围57-1964 IU/L),无肝衰竭表现。
临床怎么用
- 在腹腔镜肝切除中,可采用单极软凝设备联合肝细胞压碎法进行肝实质离断,以最大程度控制术中出血。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The popularity of laparoscopic liver resection (LLR) is spreading, worldwide, because the intraoperative blood loss is less than for open hepatectomy and it is associated with a shorter hospitalization period [1-6]. During LLR, intraoperative hemostasis is difficult to achieve, unlike during laparotomy where bleeding can be stopped instantly [7-10]. Our LLR method for the treatment of hepatocellular carcinoma (HCC) includes maximal control of intraoperative bleeding using a monopolar soft-coagulation device. Although we use a monopolar soft-coagulation device to control bleeding during LLR, while coagulating the thin blood vessels, we also developed a maneuver (the hepatocyte crush method: HeCM) to allow liver transection to progress while liver parenchymal cells are being crushed. METHOD: Between January 2008 and March 2016, we performed total LLR on 150 hepatocellular carcinoma patients (144 partial liver resections and six left lateral sectionectomies) using the maneuver shown in the video. RESULTS: The patients had Child-Pugh Scores of grade A (n = 100), B (42), or C (n = 8) and the localizations of tumor were segment (S) 1(n = 7), S2 (19), S3 (23), S4 (28), S5 (17), S6 (26), S8 (17), and S8 (29). The median blood loss was 30 (range 0-490) g during a median surgical time of 207 (range 127-468) min. One patient required conversion to a laparotomy due to the presence of severe adhesions; none of the patients required conversion due to intraoperative hemorrhage. The peak aspartate aminotransferase (AST) level was 320 (range 57-1964) IU/L. Although some patients showed high AST levels, none showed signs of hepatic failure. The median postoperative hospital stay duration was 6 (range 3-21) days. Postoperative complications occurred in seven cases (4.7%), including intraabdominal abscesses (n = 2), wound infections (2), intraabdominal hemorrhage (1), bile duct stricture (1), and umbilical hernia (1). The mortality was zero. CONCLUSION: HeCM, combined with the use of a monopolar soft-coagulation device, is a good technique for reducing bleeding during liver resection in patients with HCC.
引用
- Miyazawa M, Aikawa M, Okada K, et al. Laparoscopic liver resection using a monopolar soft-coagulation device to provide maximum intraoperative bleeding control for the treatment of hepatocellular carcinoma. Surg Endosc. 2017. PMID: 28916868. doi:10.1007/s00464-017-5829-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。