文献速递甲状腺与颈部外科围术期管理与 ERAS

术前甲状旁腺4D-CT与术中所见不一致的相关因素

Factors Associated With Discordance Between Preoperative Parathyroid 4-Dimensional Computed Tomographic Scans and Intraoperative Findings During Parathyroidectomy.
PubMed 文献 · JAMA Surg · 2017-01-01

该研究基于411例原发性甲状旁腺功能亢进患者的前瞻性数据库,分析术前4D-CT与术中病变不一致的相关因素。结果显示29.9%存在不一致,多腺体病变、病变位于下位、病变≤10mm及多结节性甲状腺肿或甲状腺结节是不一致的独立相关因素。

要点

  • 多腺体病变与4D-CT不一致的关联最强(OR 7.63)。
  • 病变位于下位(OR 6.82)和病变≤10mm(OR 4.37)也增加不一致风险。
  • 合并多结节性甲状腺肿或甲状腺结节亦与不一致相关(OR 1.82)。

核心结论

  • 多腺体病变是与术前4D-CT和术中所见不一致关联最强的因素,其次是甲状旁腺病变位于下位和病变大小≤10mm。

研究设计与样本

  • 前瞻性收集的患者数据库分析,纳入2011年9月1日至2016年10月31日期间在三级转诊中心连续接受术前4D-CT及后续甲状旁腺切除术的原发性甲状旁腺功能亢进患者,共411例。

主要发现

  • 411例患者中123例(29.9%)术前4D-CT与术中所见不一致,其中75例(18.2%)为重大不一致。
  • 不一致组多腺体病变频率高于一致组(66.7% vs 24.3%,P < .001)。
  • 不一致组多结节性甲状腺肿或甲状腺结节频率高于一致组(40.7% vs 29.2%,P = .02)。
  • 漏诊的甲状旁腺病变平均大小小于检出病变(0.86 vs 1.24 cm,P < .001),且更常位于下位(65.4% vs 38.1%,P < .001)。

关键数值与推荐

  • 病变大小≤10mm与不一致独立相关(OR 4.37;95% CI 2.24-8.54)。
  • 多腺体病变与不一致独立相关(OR 7.63;95% CI 3.49-16.69)。
  • 多结节性甲状腺肿或甲状腺结节与不一致独立相关(OR 1.82;95% CI 1.01-3.28)。
  • 病变位于下位与不一致独立相关(OR 6.82;95% CI 3.10-14.99)。

临床怎么用

  • 术前应识别多腺体病变、下位病变、小病变及合并甲状腺结节等可能降低4D-CT准确性的因素,以优化术前规划和术中排查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Parathyroid 4-dimensional computed tomographic scans (4D-CTs) have emerged as an accurate and cost-effective initial localization study for patients with primary hyperparathyroidism. However, potential limitations and factors affecting the accuracy of preoperative 4D-CTs remain poorly defined. OBJECTIVES: To characterize factors associated with missed parathyroid lesions on preoperative 4D-CTs and to investigate patterns of commonly observed errors. DESIGN, SETTING, AND PARTICIPANTS: A prospectively accrued patient database was analyzed from September 1, 2011, through October 31, 2016. The study was performed in a tertiary referral center. Consecutive patients with primary hyperparathyroidism undergoing preoperative 4D-CTs and subsequent parathyroidectomy were included in the study. MAIN OUTCOMES AND MEASURES: Discordance between preoperative 4D-CTs and intraoperative findings in the number and location of abnormal parathyroid lesions. RESULTS: Of 411 patients studied (mean [SD] age, 59 [14] years; 325 [79.1%] female), 123 (29.9%) had discordance between preoperative 4D-CTs and intraoperative findings. Among the 411 patients, 75 (18.2%) had major discordance, including incorrectly localized adenoma on the contralateral side of the neck, missed double adenoma, and absence of any abnormal lesion detected on 4D-CTs. Compared with concordant cases, discordant cases had higher frequencies of multigland disease (66.7% [82 of 123] vs 24.3% [70 of 288], P < .001) and multinodular goiter or thyroid nodule (40.7% [50 of 123] vs 29.2% [84 of 288], P = .02). Missed parathyroid lesions were smaller (mean [SD], 0.86 [0.29] vs 1.24 [0.50] cm; P < .001) and were more likely to be in the inferior position (65.4% [87 of 133] vs 38.1% [177 of 465], P < .001). Parathyroid lesion size of 10 mm or less (odds ratio [OR], 4.37; 95% CI, 2.24-8.54), multigland disease (OR, 7.63; 95% CI, 3.49-16.69), multinodular goiter or thyroid nodule (OR, 1.82; 95% CI, 1.01-3.28), and parathyroid lesion in the inferior position (OR, 6.82; 95% CI, 3.10-14.99) were independently associated with discordant 4D-CT results. CONCLUSIONS AND RELEVANCE: Multigland disease was most strongly associated with discordance between preoperative 4D-CTs and intraoperative findings, followed by parathyroid lesion in the inferior position and parathyroid lesion size of 10 mm or less. Awareness of these potential pitfalls may allow surgeons to better leverage this new localization technique in preoperative planning and intraoperative troubleshooting.

来源:JAMA Surg,查看原文。版权归原作者所有。

引用

  1. Sho S, Yuen AD, Yeh MW, et al. Factors Associated With Discordance Between Preoperative Parathyroid 4-Dimensional Computed Tomographic Scans and Intraoperative Findings During Parathyroidectomy. JAMA Surg. 2017. PMID: 28793141. doi:10.1001/jamasurg.2017.2649

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。