经口腔持续术中神经监测在经自然腔道内镜甲状腺手术中的初步应用

Application of transoral continuous intraoperative neuromonitoring in natural orifice transluminal endoscopic surgery for thyroid disease: a preliminary study.
PubMed 文献 · Surg Endosc · 2017-06-22

本研究探讨经口腔置入持续术中神经监测(Cont-IONM)在经口腔前庭入镜甲状腺切除术中的可行性与安全性。20例患者(28条风险神经)全部成功完成监测,平均耗时10.33±2.57分钟,未出现神经、心血管或胃肠道不良后果,1例出现肌电事件但术后无声带麻痹。

要点

  • 经口腔置入持续术中神经监测在经口腔前庭入镜甲状腺切除术中可行且安全。
  • 刺激参数为0.7毫安、每1秒一次,未出现神经、心血管或胃肠道不良后果。
  • 1例出现肌电事件,松开甲状腺拉钩后改善,术后无声带麻痹。

核心结论

  • 经口腔持续术中神经监测在经口腔前庭入镜甲状腺切除术中可行且安全,可能有助于早期发现不良肌电变化,从而预防喉返神经麻痹。

研究设计与样本

  • 初步研究,纳入20例接受经口腔前庭入镜甲状腺切除术的患者,共28条风险神经。

主要发现

  • 所有持续术中神经监测操作均成功完成,平均同侧监测耗时10.33±2.57分钟。
  • 除1例外未发生电极移位等显著问题;1例出现肌电事件,松开甲状腺拉钩后改善,术后无声带麻痹。

关键数值与推荐

  • 刺激参数为0.7毫安、每1秒一次;报警设置为肌电振幅下降50%且潜伏期延长10%。

临床怎么用

  • 在经口腔前庭入镜甲状腺切除术中可经口腔置入持续术中神经监测电极,按设定参数监测并关注肌电变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The novel concept of continuous intraoperative neuromonitoring (Cont-IONM) through stimulation of the vagal nerve has been used in thyroidectomies to prevent imminent injury of the recurrent laryngeal nerve (RLN). This article reports on this technology and the results of using transoral Cont-IONM in natural orifice transluminal endoscopic surgery for thyroid disease. METHODS: Cont-IONM of the RLN was achieved through automatic cyclical stimulation of the vagal nerve using a C2 monitor and delta stimulating electrode. During the operation, three vestibular incisions were made, and the stimulating electrode was transorally inserted, with its cable line lying outside the trocar. The vagal nerve was gently dissected, looped, and then enveloped by the electrode cuff. Electromyography (EMG) of the vocalis muscle was performed, and the alarm was set to activate when the EMG amplitude reduced by 50% and latency was prolonged by 10%. Demographic data and outcome variables, including incremental time required to achieve Cont-IONM, were obtained. RESULTS: A total of 20 patients (28 nerves at risk) undergoing a transoral endoscopic thyroidectomy vestibular approach were enrolled in this study. All Cont-IONM procedures were successfully completed. In all patients, the stimulation was set at 0.7 milliamps every 1 s, and Cont-IONM use was unassociated with any untoward neural, cardiovascular, or gastrointestinal sequelae. On average, the ipsilateral Cont-IONM procedure required 10.33 ± 2.57 min to complete. Except for one instance, no significant problems occurred with electrode displacement. In one patient, a combined EMG event occurred, which improved after releasing the thyroid retractor, and the patient had no vocal cord paralysis postoperatively. CONCLUSION: Cont-IONM is feasible and safe to use during transoral endoscopic thyroidectomies and may assist in the early detection of adverse EMG changes, thereby preventing paralysis of the RLNs.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Chen HK, Chen CL, Wen KS, et al. Application of transoral continuous intraoperative neuromonitoring in natural orifice transluminal endoscopic surgery for thyroid disease: a preliminary study. Surg Endosc. 2017. PMID: 28643050. doi:10.1007/s00464-017-5656-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。