机器人双瓣法瓣膜成形食管胃吻合用于近端胃切除术:技术要点与短期结局
本研究评估机器人辅助双瓣法瓣膜成形食管胃吻合(VEG-DFT)在近端胃切除术后的可行性与安全性。12例连续患者均顺利完成机器人手术,30天内死亡率和并发症率均为0%,无术后反流性食管炎,但3例(25%)出现吻合口狭窄需内镜下球囊扩张,且吻合口狭窄与VEG-DFT缝合总针数显著相关(p < 0.001)。
要点
- 机器人VEG-DFT可行且安全,短期无死亡和并发症。
- 术后无反流性食管炎,但25%患者出现吻合口狭窄。
- 吻合口狭窄与缝合总针数显著相关,应避免过多缝合。
核心结论
- 机器人辅助VEG-DFT学习曲线短,短期结局可接受。
- 需注意避免过多缝合以预防吻合口狭窄。
研究设计与样本
- 单中心连续病例系列,纳入2014年1月至2015年12月行机器人VEG-DFT的12例患者。
主要发现
- 所有手术均机器人辅助完成,中位手术时间406分钟(范围324-613),外科医生控制台时间267分钟(214-483),吻合时间104分钟(76-186)。
- 中位估计出血量31 ml(范围5-130),术后中位住院10天(范围9-30)。
- 30天内死亡率和并发症率均为0%。
- 术后无反流性食管炎,3例(25%)在术后第2个月出现吻合口狭窄需内镜下球囊扩张。
- 吻合口狭窄与VEG-DFT缝合总针数显著相关(p < 0.001)。
临床怎么用
- 机器人VEG-DFT可作为近端胃切除后防反流的重建选项。
- 术中应控制食管胃吻合的缝合针数,以降低吻合口狭窄风险。
局限性
- 样本量小(12例),为单中心回顾性分析。
- 随访时间短,仅评估短期结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Valvuloplastic esophagogastrostomy by double flap technique (VEG-DFT) is a promising procedure to prevent reflux after proximal gastrectomy (PG), and is achieved by the burial of the abdominal esophagus into the gastric submucosa; however, laparoscopic VEG-DFT is technically demanding due to complicated suturing and ligation maneuvers. The present study was designed to determine the feasibility and safety of robotic VEG-DFT. METHODS: After robotic PG, seromuscular flaps were extracorporeally created at the anterior wall of the remnant stomach through a small umbilical incision. Then, using a robot, the posterior wall of the esophagus was fixed to the cranial end of the mucosal window, and layer-to-layer sutures were placed between the anterior aspects of esophagus and the remnant stomach. Finally, the anastomosis was covered by seromuscular flaps. Short-term outcomes of 12 consecutive patients who underwent VEG-DFT between January 2014 and December 2015 were assessed. RESULTS: Operations were successfully completed using robotic assistance in all patients. Median operative, surgeon console, and anastomosis times were 406 (324-613 min), 267 (214-483), and 104 (76-186) min, respectively, and median estimated blood loss was 31 (5-130) ml. The first six cases were required to reach a learning plateau. Both mortality and morbidity rates within 30 days after surgery were 0%. Postoperative hospital stay was 10 (9-30) days. No postoperative reflux esophagitis was observed, whereas anastomotic stenosis, which required endoscopic balloon dilation, developed in three patients (25%) in postoperative month 2. There was a significant association between the total number of stitches used for VEG-DFT and anastomotic stenosis (p < 0.001). CONCLUSIONS: Robotic assistance may be useful for VEG-DFT with a short learning curve. Attention is required to prevent postoperative anastomotic stenosis possibly caused by an excessive number of stitches for esophagogastrostomy.
引用
- Shibasaki S, Suda K, Nakauchi M, et al. Robotic valvuloplastic esophagogastrostomy using double flap technique following proximal gastrectomy: technical aspects and short-term outcomes. Surg Endosc. 2017. PMID: 28364148. doi:10.1007/s00464-017-5489-x