HIPPO试验:自固定补片与缝合补片在Lichtenstein疝修补术中的长期随访
结果显示两组慢性术后腹股沟疼痛发生率无差异,复发率亦无显著差异,但Progrip组手术时间显著缩短。
要点
- 自固定Progrip补片未降低慢性术后腹股沟疼痛发生率。
- 两组复发率无显著差异,Progrip组为2.4%,缝合组为1.8%。
- Progrip补片可显著缩短手术时间(44分钟 vs 53分钟)。
核心结论
- 自固定Progrip补片不能降低Lichtenstein疝修补术后慢性腹股沟疼痛的发生率。
- Progrip补片的效果与缝合补片相当,且具有缩短手术时间的额外优势。
研究设计与样本
- 随机双盲试验,纳入成年男性原发性单侧腹股沟疝行Lichtenstein疝修补术患者。
- Progrip补片组165例,缝合补片组166例,随访至术后24个月。
主要发现
- 慢性术后腹股沟疼痛发生率在3个月时为7.3%,24个月时降至4.6%,两组间无差异。
- 术后2年疼痛和生活质量评分均显著改善。
- 术后24个月复发率:Progrip组2.4%,缝合组1.8%(P=0.213)。
- 平均手术时间Progrip组显著短于缝合组(44分钟 vs 53分钟,P<0.001)。
关键数值与推荐
- 慢性术后腹股沟疼痛定义为术后持续至少3个月的中度疼痛。
- 疼痛和生活质量采用语言评定量表、视觉模拟评分和SF-36评估。
临床怎么用
- 自固定补片可作为Lichtenstein疝修补术的一种选择,不增加慢性疼痛或复发风险,且可能缩短手术时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the effect of a self-gripping mesh (Progrip) on the incidence of chronic postoperative inguinal pain (CPIP) and recurrence rate after Lichtenstein hernioplasty. BACKGROUND: Chronic pain is the most common complication of inguinal hernioplasty. One of the causes may be the use of sutures to secure the mesh. METHODS: Adult male patients undergoing Lichtenstein hernioplasty for a primary unilateral inguinal hernia were randomized to a self-gripping polyester mesh or a sutured polyester mesh. Follow-up took place after 2 weeks, 3, 12, and 24 months. Pain and quality of life were assessed using the Verbal Rating Scale, Visual Analog Scale, and Short Form 36. CPIP was defined as moderate pain lasting at least 3 months postoperatively. RESULTS: There were 165 patients in the Progrip mesh group and 166 patients in the sutured mesh group. The incidence of CPIP was 7.3% at 3 months declining to 4.6% at 24 months and did not differ between both groups. Pain and quality of life scores were significantly improved after 2 years. Hernia recurrence rate after 24 months was 2.4% for the Progrip mesh and 1.8% for the sutured mesh (P = 0.213). The mean duration of surgery was significant shorter with the Progrip mesh (44 vs 53 minutes, P < 0.001). CONCLUSIONS: The self-gripping Progrip mesh does not reduce CPIP rates. Outcomes of the Progrip mesh are comparable to the Lichtenstein technique with the additional advantage of a reduced operation time. NCT01830452.
引用
- Molegraaf MJ, Grotenhuis B, Torensma B, et al. The HIPPO Trial, a Randomized Double-blind Trial Comparing Self-gripping Parietex Progrip Mesh and Sutured Parietex Mesh in Lichtenstein Hernioplasty: A Long-term Follow-up Study. Ann Surg. 2017. PMID: 28257318. doi:10.1097/SLA.0000000000002169
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。