文献速递胃肠外科围术期管理与 ERAS

ICG荧光成像在腹腔镜结直肠手术中定量评估结肠灌注

ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery.
PubMed 文献 · Surg Endosc · 2017-03-09

该回顾性研究分析112例左侧结直肠癌腹腔镜手术患者,采用ICG荧光成像定量指标(Fmax、Tmax、T1/2、Slope)评估吻合口灌注并指导近端结肠切除线。结果显示Fmax截断值52.0预测吻合口漏的敏感度100%、特异度92.5%,且Tmax与术后肠功能恢复相关。

要点

  • ICG定量参数Fmax≤52.0可预测吻合口漏,敏感度100%、特异度92.5%。
  • 需向近端改变切除线的患者吻合口漏发生率22.2%,无需改变者为1.0%。
  • Tmax较低者术后排气或排便恢复更早。

核心结论

  • ICG荧光成像有助于评估结直肠手术吻合口灌注,支持更精准的个体化手术决策。

研究设计与样本

  • 回顾性分析前瞻性维护数据库,纳入112例左侧结直肠癌腹腔镜手术患者。

主要发现

  • 吻合口漏发生5例(4.5%)。
  • 18例(16.1%)基于荧光成像向近端改变切除线,其中4例(22.2%)发生吻合口漏。
  • 未改变切除线的94例中仅1例(1.0%)发生吻合口漏。
  • 吻合口漏组5例Fmax均小于52.0,非吻合口漏组107例中仅8例Fmax小于52.0。
  • 早期排气或排便组Tmax分别显著低于晚期排气或排便组。

关键数值与推荐

  • Fmax截断值52.0预测吻合口漏的敏感度100%、特异度92.5%。

临床怎么用

  • 术中可利用ICG荧光成像定量参数Fmax评估吻合口灌注,辅助决定近端结肠切除线。
  • Fmax低于52.0时需警惕吻合口漏风险,考虑进一步向近端调整切除线。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fluorescence technology with indocyanine green (ICG) provides a real-time assessment of intestinal perfusion. However, a subjective evaluation of fluorescence intensity based on the surgeon's visual judgement is a major limitation. This study evaluated the quantitative assessment of ICG fluorescence imaging in determining the transection line of the proximal colon during laparoscopic colorectal surgery. METHODS: This is a retrospective analysis of a prospectively maintained database of 112 patients who underwent laparoscopic surgery for left-sided colorectal cancers. After distal transection of the bowel, the specimen was extracted extracorporeally and then the proximal colon was divided within the well-perfused area based on the ICG fluorescence imaging. We evaluated whether quantitative assessment of intestinal perfusion by measuring ICG intensity could predict postoperative outcomes: F max, T max, T 1/2, and Slope were calculated. RESULTS: Anastomotic leakage (AL) occurred in 5 cases (4.5%). Based on the fluorescence imaging, the surgical team opted for further proximal change of the transection line up to an "adequate" fluorescent portion in 18 cases (16.1%). Among the 18 patients, AL occurred in 4 patients (4/18: 22.2%), whereas it occurred in only 1 case (1/94: 1.0%) in the good perfusion patients who did not need proximal change of the transection line. The F max of the AL group was less than 52.0 in all 5 cases (5/5), whereas that of the non-AL group was in only 8 cases (8/107): with an F max cutoff value of 52.0, the sensitivity and specificity for the prediction of AL were 100 and 92.5%, respectively. Regarding postoperative bowel movement recovery, the T max of the early flatus group or early defecation group was significantly lower than that of the late flatus group or late defecation group, respectively. CONCLUSIONS: ICG fluorescence imaging is useful for assessing anastomotic perfusion in colorectal surgery, which can result in more precise operative decisions tailored for an individual patient.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Wada T, Kawada K, Takahashi R, et al. ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery. Surg Endosc. 2017. PMID: 28281123. doi:10.1007/s00464-017-5475-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。