血管环调节门静脉血流促进猪部分肝切除后肝再生
该研究在17头大白猪的75%肝切除模型中,评估经皮可调血管环(MID-AVR)临时调节门静脉血流的安全性和有效性。结果显示MID-AVR操作安全,可降低门腔压力梯度、减轻术后高胆红素血症,并保护肝微架构、促进肝再生。
要点
- MID-AVR经皮充气、放气和移除操作安全。
- MID-AVR组术后门腔压力梯度更低(P=0.001)。
- MID-AVR可能通过保护肝微架构改善肝再生。
核心结论
- MID-AVR用于门静脉血流调节是安全的,可能通过保护肝微架构改善肝再生。
研究设计与样本
- 在17头大型白猪中行75%肝切除,分为MID-AVR组8头和对照组,MID-AVR组门静脉周围放置血管环3天。
主要发现
- MID-AVR组和对照组分别有2头(25%)和4头(45%)在术后第3天前死亡(P=NS)。
- 肝切除后门静脉血流率每肝质量适度增加与更好的生存相关(P=0.017)。
- MID-AVR组肝切除后门腔压力梯度更低(P=0.001)。
- MID-AVR组术后第5天血清胆红素水平更低(P=0.007)。
- MID-AVR组第3天Ki67指数显著更高(P=0.043),架构紊乱程度更低(P<0.05)。
关键数值与推荐
- 对照组第7天胆管形态计量显示交叉分支数显著减少(P<0.05),交叉节点数显著减少(P<0.001),而MID-AVR组无此差异。
临床怎么用
- MID-AVR或可作为大范围肝切除后调节门静脉血流、预防术后肝衰竭的潜在策略。
局限性
- 研究为猪模型,样本量较小(17头),结论需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate safety and efficacy of temporary portal hemodynamics modulation with a novel percutaneously adjustable vascular ring (MID-AVR) onto a porcine model of 75% hepatectomy. BACKGROUND: Postoperative liver failure is a leading cause of mortality after major hepatectomy. Portal flow modulation is an increasingly accepted concept to prevent postoperative liver failure. Nonetheless, the current strategies have shortcomings. METHODS: Resection was performed under hemodynamic monitoring in 17 large, white pigs allocated into 2 groups. Eight pigs had ring around the portal vein for 3 days with the aim of reducing changes in hemodynamics due to hepatectomy. Analysis of hemodynamics, laboratory, and histopathological parameters was performed. RESULTS: Percutaneous inflation, deflation, and removal of the MID-AVR were safe. Two (25%) pigs in the MID-AVR group and 4 (45%) controls died before day 3 (P = NS). A moderate increase of portal flow rate per liver mass after resection was associated with better survival (P = 0.017). The portocaval pressure gradient was lower after hepatectomy in the MID-AVR group (P = 0.001). Postoperative serum bilirubin levels were lower in the MID-AVR group (P = 0.007 at day 5). In the MID-AVR group, the Ki67 index was significantly higher on day 3 (P = 0.043) and the architectural derangement was lower (P < 0.05). Morphometric quantification of the bile canaliculi revealed a significantly lower number of intersection branches (P < 0.05) and intersection nodes (P < 0.001) on day 7 compared with the preoperative specimen, in the control group. These differences were not found in the ring group. CONCLUSIONS: MID-AVR is safe for portal hemodynamics modulation. It might improve liver regeneration by protecting liver microarchitecture.
引用
- Bucur PO, Bekheit M, Audebert C, et al. Modulating Portal Hemodynamics With Vascular Ring Allows Efficient Regeneration After Partial Hepatectomy in a Porcine Model. Ann Surg. 2018. PMID: 28151798. doi:10.1097/SLA.0000000000002146
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。