吲哚菁绿荧光血管造影定量评估甲状腺全切除术后原位甲状旁腺灌注与功能
BACKGROUND: Because the fluorescent light intensity on an indocyanine green fluorescence angiography reflects the blood perfusion within a focused area, the fluorescent light intensity in the remaining in situ parathyroid glands may predict postoperative hypocalcemia risk after t…
要点
- 最大荧光强度>150%者无术后低钙血症发生。
- 最大荧光强度≤150%者81.8%发生术后低钙血症。
- 最大荧光强度预测低钙血症优于术后第0天低钙和PTH下降。
核心结论
- 吲哚菁绿荧光血管造影是确定残余甲状旁腺功能和预测甲状腺全切除术后低钙血症风险的有前景的术中辅助手段。
研究设计与样本
- 有血管蒂的甲状旁腺留原位,无蒂或误切者自体移植。
- 术后低钙血症定义为24小时内校正钙<2.00 mmol/L。
主要发现
- 变色与外观正常的吲哚菁绿荧光血管造影荧光强度相似(P = .479)。
- 最大荧光强度>150%的患者无术后低钙血症发生,而最大荧光强度≤150%的患者中9例(81.8%)发生术后低钙血症。
- 平均荧光强度>109%的患者无术后低钙血症发生,而平均荧光强度≤109%的患者中9例(30%)发生术后低钙血症。
- 最大荧光强度对术后低钙血症的预测优于术后第0天低钙血症(P = .027)和术后第0至1天PTH下降百分比(P < .001)。
临床怎么用
- 甲状腺全切除术后可行吲哚菁绿荧光血管造影定量评估原位甲状旁腺灌注,辅助预测术后低钙血症风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Because the fluorescent light intensity on an indocyanine green fluorescence angiography reflects the blood perfusion within a focused area, the fluorescent light intensity in the remaining in situ parathyroid glands may predict postoperative hypocalcemia risk after total thyroidectomy. METHODS: Seventy patients underwent intraoperative indocyanine green fluorescence angiography after total thyroidectomy. Any parathyroid glands with a vascular pedicle was left in situ while any parathyroid glands without pedicle or inadvertently removed was autotransplanted. After total thyroidectomy, an intravenous 2.5 mg indocyanine green fluorescence angiography was given and real-time fluorescent images of the thyroid bed were recorded using the SPY imaging system (Novadaq, Ontario, Canada). The fluorescent light intensity of each indocyanine green fluorescence angiography as well as the average and greatest fluorescent light intensity in each patient were calculated. Postoperative hypocalcemia was defined as adjusted calcium <2.00 mmol/L within 24 hours. RESULTS: The fluorescent light intensity between discolored and normal-looking indocyanine green fluorescence angiographies was similar (P = .479). No patients with a greatest fluorescent light intensity >150% developed postoperative hypocalcemia while 9 (81.8%) patients with a greatest fluorescent light intensity ≤150% did. Similarly, no patients with an average fluorescent light intensity >109% developed PH while 9 (30%) with an average fluorescent light intensity ≤109% did. The greatest fluorescent light intensity was more predictive than day-0 postoperative hypocalcemia (P = .027) and % PTH drop day-0 to 1 (P < .001). CONCLUSION: Indocyanine green fluorescence angiography is a promising operative adjunct in determining residual parathyroid glands function and predicting postoperative hypocalcemia risk after total thyroidectomy.
引用
- Lang BH, Wong CK, Hung HT, et al. Indocyanine green fluorescence angiography for quantitative evaluation of in situ parathyroid gland perfusion and function after total thyroidectomy. Surgery. 2016. PMID: 27839936. doi:10.1016/j.surg.2016.03.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。