喉部超声不同频率对声带评估的比较
本研究针对甲状腺切除及其他颈部手术患者,比较高频(12-5 MHz)与低频(9-3 MHz)喉部超声对声带可视化的效果,并以直接喉镜交叉验证。结果显示低频超声的可视化率、敏感度和特异度均优于高频超声,推荐在可用时使用低频探头进行喉部超声评估声带麻痹。
要点
- 低频喉部超声可视化率97.7%,高于高频的88.4%。
- 低频超声敏感度97.6%、特异度96.5%,均优于高频。
- 推荐使用9-3 MHz低频探头行喉部超声评估声带。
核心结论
- 低频喉部超声显著提升声带可视化,尤其适用于弥漫性甲状软骨钙化患者。
- 低频喉部超声作为围术期声带麻痹诊断工具的整体效能更优。
研究设计与样本
- 共纳入301例(男55例,女246例)连续接受喉部超声和直接喉镜检查的甲状腺切除及其他颈部手术患者。
- 所有喉部超声均使用高频(12-5 MHz宽带谱)和低频(9-3 MHz宽带谱)探头,结果与直接喉镜独立交叉验证。
主要发现
- 高频和低频喉部超声的可视化率分别为88.4%和97.7%。
- 低频喉部超声敏感度97.6%、特异度96.5%;高频喉部超声敏感度92.9%、特异度86.5%。
关键数值与推荐
- 推荐在可用时使用低频探头(约9-3 MHz)进行喉部超声。
临床怎么用
- 在甲状腺及颈部手术围术期评估声带麻痹时,优先选用低频喉部超声以提高可视化率和诊断准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Laryngeal ultrasound is a new method of vocal cord evaluation in patients at risk for vocal cord palsy. However, the previously described laryngeal ultrasound reportedly has a high failure rate of vocal cord visualization in male patients. We compared 2 ultrasound frequencies in laryngeal ultrasound to improve on the limitations of this method. METHOD: A total of 301 (55 male, 246 female) consecutive laryngeal ultrasound and direct laryngoscopy exams were performed for patients with thyroidectomy and other neck operations. High-frequency transducer (12-5 MHz broad band spectrum) and low-frequency transducer (9-3 MHz broad band spectrum) were used for all laryngeal ultrasound. Findings were independently cross-validated with direct laryngoscopy. RESULTS: High-frequency and low-frequency laryngeal ultrasound had 88.4% and 97.7% visualization rates, respectively. In addition, low-frequency laryngeal ultrasound showed improved sensitivity of 97.6% and specificity of 96.5%, compared with a sensitivity of 92.9% and specificity of 86.5% for high-frequency laryngeal ultrasound in vocal cord evaluation. CONCLUSION: The low-frequency laryngeal ultrasound method significantly enhances the visualization of vocal cords, especially in patients who have diffuse thyroid cartilage calcification interrupting laryngeal ultrasound, and therefore enhances the overall efficacy of laryngeal ultrasound as a perioperative diagnostic tool for vocal cord palsy. Hence, we recommend using a low-frequency transducer (about 9-3 MHz) for laryngeal ultrasound if it is available.
引用
- Woo JW, Park I, Choe JH, et al. Comparison of ultrasound frequency in laryngeal ultrasound for vocal cord evaluation. Surgery. 2016. PMID: 27871685. doi:10.1016/j.surg.2016.10.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。