文献速递围术期管理与 ERAS

简化胸腔镜微创消融技术治疗孤立性房颤:OC盒式钳夹消融

A simplified and effective thoracoscopic minimally invasive ablation technique for lone atrial fibrillation: OC-box clamping ablation.
PubMed 文献 · Surgery · 2026-09-29

本研究纳入169例孤立性房颤患者,比较全胸腔镜外科消融(63例)与OC盒式钳夹消融(106例)的安全性和有效性。结果显示两种方法在4、6、12个月无抗心律失常药物下免于房颤/房速的成功率无显著差异,但OC盒式钳夹消融手术时间显著缩短。左心房增大与房颤复发相关。

要点

  • OC盒式钳夹消融与全胸腔镜消融在12个月内的疗效和安全性相当。
  • OC盒式钳夹消融手术时间显著短于全胸腔镜消融(127.31±22.20分钟 vs 160.29±45.94分钟)。

核心结论

  • OC盒式钳夹消融治疗孤立性房颤的疗效和安全性不劣于全胸腔镜外科消融,且手术时间更短、更易于初学者掌握。

研究设计与样本

  • 回顾性队列研究,纳入169例孤立性房颤患者,其中全胸腔镜外科消融63例,OC盒式钳夹消融106例,均完成12个月随访。

主要发现

  • 围术期无死亡、卒中、心血管损伤或需要IABP/ECMO支持的事件。

临床怎么用

  • 对于孤立性房颤,OC盒式钳夹消融可作为全胸腔镜外科消融的简化替代方案,尤其适合初学者。
  • 术前评估左心房大小有助于识别房颤复发高风险患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Thoracoscopic minimally invasive ablation is effective for lone atrial fibrillation but remains technically challenging. Simplified modifications are needed to improve feasibility while maintaining outcomes. OBJECTIVE: We proposed a simplified procedure, OC-box clamping ablation, for patients with lone atrial fibrillation and evaluated its safety, effectiveness, and simplicity. METHODS: A total of 169 patients with lone atrial fibrillation underwent either totally thoracoscopic surgical ablation (n = 63) or OC-box clamping ablation (n = 106) and completed 12-month follow-up. Statistical analysis was performed to compare the rates of freedom from atrial fibrillation/atrial tachycardia without antiarrhythmic drugs at 4, 6, and 12 months postoperatively, as well as complications and adverse events. Logistic regression identified risk factors for atrial fibrillation recurrence. RESULTS: No perioperative mortality, stroke, cardiovascular injury, or intra-aortic balloon pump/extracorporeal membrane oxygenation support was observed. No significant differences were observed in freedom from atrial fibrillation/atrial tachycardia without antiarrhythmic drugs at 4, 6, and 12 months between totally thoracoscopic surgical and OC-box clamping ablations (84.1% vs 86.8%, P = .631; 81.0% vs 77.4%, P = .581; and 71.4% vs 76.4%, P = .472). However, OC-box clamping ablation demonstrated a significantly shorter operative time compared with the totally thoracoscopic surgical ablation (127.31 ± 22.20 minutes vs 160.29 ± 45.94 minutes; P < .01). An enlarged left atrium was associated with atrial fibrillation recurrence (odds ratio, 2.810; 95% confidence interval, 1.145-6.897; P = .024). CONCLUSION: OC-box clamping ablation achieves comparable efficacy and safety to totally thoracoscopic surgical ablation, with a simplified process and shorter operative time, making it more beginner-friendly.

来源:Surgery,查看原文。版权归原作者所有。

引用

  1. Tong Q, Xu S, Sun Y, et al. A simplified and effective thoracoscopic minimally invasive ablation technique for lone atrial fibrillation: OC-box clamping ablation. Surgery. 2026. PMID: 42934006. doi:10.1016/j.surg.2026.110702

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。