微创腹股沟疝修补中一次性与混合穿刺器的伤口感染比较
基于ACHQC数据库纳入2017至2023年择期微创腹股沟疝修补合并补片患者34,638例,按术者惯用穿刺器类型分组并行倾向评分匹配,每组1191例。两组手术部位感染、需操作干预的手术部位事件、再入院及再手术率均无差异,一次性穿刺器组手术部位事件发生率更高。
要点
- 混合穿刺器与一次性穿刺器在微创腹股沟疝修补中手术部位感染风险无差异。
- 一次性穿刺器组手术部位事件发生率更高,主要由血肿发生率较高驱动。
- 为减少手术废弃物,术者可考虑在腹腔镜手术中使用混合穿刺器。
核心结论
- 微创腹股沟疝修补中,混合穿刺器相比一次性穿刺器未增加手术部位感染风险。
- 一次性穿刺器组手术部位事件发生率显著更高,但需操作干预的手术部位事件无差异。
研究设计与样本
- 利用腹壁核心健康质量协作组织(ACHQC)数据库,识别仅用一次性穿刺器的腹腔镜腹股沟疝修补高流量术者及用混合穿刺器的机器人腹股沟疝修补术者,以两种术式作为穿刺器类型的替代比较。
- 查询2017至2023年上述术者完成的择期微创腹股沟疝修补合并补片患者,共34,638例符合纳入标准,倾向评分匹配后每组1191例。
主要发现
- 匹配后两组手术部位感染、需操作干预的手术部位事件、再入院及再手术率均无差异。
- 一次性穿刺器组手术部位事件发生率为5%,混合穿刺器组为2%,差异有统计学意义(p=0.003)。
- 一次性穿刺器组血肿发生率显著更高(12% vs 38%,p=0.007)。
临床怎么用
- 对微创腹股沟疝修补,混合穿刺器不增加手术部位感染风险,可作为减少手术废弃物的选择。
- 关注一次性穿刺器组较高的手术部位事件与血肿发生率,术后需相应观察。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Operating rooms generate 70% of hospital waste. Transitioning from disposable to reusable devices could mitigate surgical waste. Partially reusable, or hybrid, trocars can be used for minimally invasive surgery (MIS), but perceptions of increased infection risk may drive preferences toward disposable trocars. However, no data substantiates this risk. Our analysis of a national hernia outcomes database investigates this presumed association. METHODS: Using the abdominal core health quality collaborative (ACHQC), we identified high-volume inguinal hernia surgeons who used only disposable trocars for laparoscopic inguinal hernia repair (IHR) and hybrid trocars for robotic IHR. These two surgical approaches served as surrogates to evaluate differences between disposable and hybrid trocars. We performed a query of the ACHQC to identify patients who underwent elective MIS IHR with mesh between 2017 and 2023 by one of the previously identified surgeons. RESULTS: A total of 34,638 patients met inclusion criteria. After propensity score matching, there were 1191 patients in each group. There was no difference in rates of surgical site infection (SSI), surgical site occurrence requiring procedural intervention (SSOPI), readmission or reoperation between the two groups. There was a statistically significant higher rate of surgical site occurrence (SSO) in the disposable trocar group (5% vs. 2%, p = 0.003). This was driven by a significantly higher rate of hematomas (12% vs 38%, p = 0.007). CONCLUSION: This study did not find an increased risk of SSI associated with hybrid trocars compared to disposable trocars for MIS inguinal hernia repairs. To decrease surgical waste, surgeons should consider the use of hybrid trocars for laparoscopic surgery.
引用
- Woo KP, Alipouriani A, Gross A, et al. Access without excess: a comparison of wound infections with disposable versus hybrid trocars in minimally invasive inguinal hernia repairs. Surg Endosc. 2026. PMID: 42836990. doi:10.1007/s00464-026-13408-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。