欧洲内分泌外科医师学会关于甲状腺手术中自发荧光和/或吲哚菁绿使用的推荐
欧洲内分泌外科医师学会(ESES)基于范围综述和荟萃分析制定推荐,经改良德尔菲投票批准。荟萃分析显示,近红外自发荧光(NIRAF)联合或不联合吲哚菁绿(ICG)在暂时性或永久性甲状旁腺功能减退、误切比例及自体移植比例方面结果良好,多数推荐证据质量评为中等。
要点
- NIRAF联合或不联合ICG可辅助甲状旁腺识别,降低术后甲状旁腺功能减退风险。
- 推荐基于34项研究(9322例)的荟萃分析,多数证据质量中等。
- ESES推荐经改良德尔菲在线投票批准,适用于甲状腺手术中评估甲状旁腺。
核心结论
- ESES推荐基于范围综述、荟萃分析和专家意见,为甲状腺手术中使用NIRAF联合或不联合ICG提供指导。
研究设计与样本
- 最终纳入34项研究,共9322例患者,发表于2017至2024年,包括11项RCT。
主要发现
- 荟萃分析显示,NIRAF和ICG在暂时性和永久性甲状旁腺功能减退、误切比例及自体移植比例方面结果良好。
关键数值与推荐
- 多数推荐的证据质量评为中等,多数问题的证据质量良好。
临床怎么用
- 甲状腺手术中可考虑使用NIRAF联合或不联合ICG评估甲状旁腺,以辅助识别并降低术后甲状旁腺功能减退风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Postoperative hypoparathyroidism remains the most frequent complication after total thyroidectomy. Recently, near-infrared autofluorescence (NIRAF) imaging with or without indocyanine green (ICG) was introduced to evaluate parathyroid glands during surgery. The aim of this paper is to provide recommendations by the European Society of Endocrine Surgeons (ESES) regarding its use in thyroid surgery based on a scoping review and meta-analysis. METHODS: A working group of experts was created by the ESES. A systematic literature search was performed, using MEDLINE® (PubMed), up to 31 December 2024. Studies were included if a comparative group was used to evaluate short- and long-term postoperative hypoparathyroidism, autotransplantation rates, and/or inadvertent parathyroid gland removal. The results were pooled in a random-effects meta-analysis. Subgroup analyses were performed to assess the impact of NIRAF with or without ICG, as well as central lymph node neck dissection. Recommendations were created among all co-authors and discussed at the 11th ESES conference. A modified Delphi online voting process amongst all members approved all recommendations. RESULTS: After screening 335 abstracts, there were 34 studies, with a total of 9322 patients, that met the inclusion criteria. These were published between 2017 and 2024 and included 11 RCTs. Meta-analyses showed promising results for NIRAF and ICG with regard to immediate and permanent hypoparathyroidism, inadvertent removal proportions, and autotransplantation proportions. The quality of evidence was rated as 'moderate' for most of the recommendations with good quality of evidence for most questions. CONCLUSION: These ESES recommendations provide guidance for the use of NIRAF with or without ICG based on a scoping review of the literature, meta-analyses, and expert opinion.
引用
- Van Den Heede K, Triponez F, Agcaoglu O, et al. Use of autofluorescence and/or indocyanine green in thyroid surgery: recommendations by the European Society of Endocrine Surgeons (ESES). Br J Surg. 2026. PMID: 42929023. doi:10.1093/bjs/znag118
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。