文献速递肝胆胰外科围术期管理与 ERAS

机器人胰十二指肠切除术中肝管空肠吻合口胆漏与胆道变异:术中检测与管理

Hepaticojejunostomy bile leakage and aberrant biliary anatomy during robotic pancreatoduodenectomy: intraoperative detection and management.
PubMed 文献 · Surg Endosc · 2026-08-31

该回顾性探索性队列研究纳入238例在单中心接受机器人胰十二指肠切除术的成人患者,通过标准化手术记录回顾术中「HJ纱布试验」发现的胆漏、多吻合口、联合胆管及支架放置情况。常规术中HJ纱布试验检出21例(9%)胆漏并均行术中修复,术后胆漏发生率14%(3/21),无死亡;术中胆漏组术后胆漏率与无胆漏组差异无统计学意义(OR 2.83,95%CI 0.47-11.91,P=0.12)。

要点

  • 常规术中HJ纱布试验可检出9%的肝管空肠吻合口胆漏,均可行术中修复。
  • 术中修复方式包括直接缝合(62%)和空肠-肝门板锚定缝合(38%)。
  • 非标准HJ构建和胆道解剖变异罕见,多吻合口占2%,支架置入占3%。

核心结论

  • 机器人胰十二指肠切除术中常规使用HJ纱布试验可能有助于检测术中胆漏,术中修复(直接缝合或锚定缝合)后结局相似。

研究设计与样本

  • 回顾性探索性队列研究,纳入2018年12月至2025年3月单中心接受机器人胰十二指肠切除术的成人患者238例。

主要发现

  • 术中HJ纱布试验检出胆漏21例(9%),其中直接缝合13例(62%),空肠-肝门板锚定缝合8例(38%)。
  • 术中检出胆漏患者术后胆漏发生3/21(14%),死亡率0/21(0%)。
  • 5例(2%)患者接受两个HJ,8例(3%)患者HJ置入支架,共11例中0例(0%)发生胆漏。
  • 术中胆漏组术后胆漏率非显著高于无术中胆漏组(3例[14%] vs 12例[6%]),OR 2.83(95%CI 0.47-11.91),Fisher精确检验P=0.12。

关键数值与推荐

  • 仅纳入ISGLS胆漏B/C级。
  • 术中胆漏通过额外直接缝合或若认为不安全则行空肠与肝门板锚定缝合管理。

临床怎么用

  • 在机器人胰十二指肠切除术中可常规行HJ纱布试验以检测术中胆漏。
  • 发现胆漏后可根据情况选择直接缝合或空肠-肝门板锚定缝合进行术中修复。

局限性

  • 回顾性探索性单中心研究,样本量有限,术中胆漏与术后胆漏关联的统计效能不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Bile leakage from the hepatico-jejunostomy (HJ) is a rare but potentially lethal complication during robotic pancreatoduodenectomy (RPD). The rate of intraoperatively detected bile leakage from the HJ and aberrant biliary anatomy during RPD and its optimal management remains unclear. METHODS: This retrospective and exploratory cohort study included all adult patients undergoing RPD at a single high-volume center (December 2018-March 2025). Standardized operating reports were reviewed regarding: (a) intraoperative bile leakage observed during the routinely performed 'HJ gauze test,' (b) multiple HJ anastomoses, (c) joined bile ducts, or (d) placement of a HJ stent. Bile leakage was managed intraoperatively by additional direct sutures or, if not deemed safe, by anchoring sutures between the jejunum and the hilar plate. Only ISGLS bile leakage grade B/C was included. RESULTS: Overall, 238 patients undergoing RPD were included. The routinely performed intraoperative 'HJ gauze test' detected bile leakage in 21 (9%) patients, all of whom underwent intraoperative surgical repair: 13 (62%) direct sutures and 8 (38%) anchoring sutures to the hilar plate. In these patients, postoperative bile leakage occurred in 3/21 (14%) patients with 0/21 (0%) mortality. Overall, 5 (2%) patients received two HJs, and 8 (3%) patients received a stent in the HJ with 0/11 (0%) bile leakage. Patients with intraoperative findings of bile leakage had a non-significant higher rate of postoperative bile leakage (3 patients [14%] vs 12 patients [6%]) (OR 2.83, 95% CI 0.47 to 11.91, Fisher's exact test p = 0.12). CONCLUSION: Routine use of the 'HJ gauze test' during RPD may be useful to detect intraoperative bile leakage, with similar outcomes after intraoperative repair (either with direct sutures or anchoring sutures). Non-standard HJ constructions and bile duct anatomy variants were rare.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Swartling O, Menso JE, Daams F, et al. Hepaticojejunostomy bile leakage and aberrant biliary anatomy during robotic pancreatoduodenectomy: intraoperative detection and management. Surg Endosc. 2026. PMID: 42675306. doi:10.1007/s00464-026-13067-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。