韩国三家三级医院2024年1–12月回顾性纳入60例机器人腹壁疝修补患者,标准化采用eTEP、TAR及TAPP技术。TAR占73.3%,无中转开腹,仅1例(1.7%)发生Clavien-Dindo IIIa级并发症,3个月随访无复发,提示该技术在韩国多中心安全可行。

要点

  • 机器人成分分离技术在多中心标准化实施下无中转开腹,主要并发症率低。
  • TAR是最常用术式(73.3%),平均手术时间274.1分钟,平均住院3.7天。
  • 3个月随访无复发,但需更长期随访确认耐久性。

核心结论

  • 机器人腹壁疝修补采用成分分离技术在韩国多中心实践中安全可行。

研究设计与样本

  • 回顾性多中心队列研究,纳入2024年1–12月韩国三家三级医院60例机器人腹壁疝修补患者。
  • 术式包括eTEP、TAR和TAPP,各中心采用标准化手术方案以减少差异。

主要发现

  • 平均年龄53.4±13.6岁(95%CI 49.9–56.8),平均BMI 28.5±5.8 kg/m2(95%CI 26.9–29.9)。
  • 平均疝宽度6.7±3.5 cm(95%CI 5.8–7.5),平均疝高度8.7±5.0 cm(95%CI 7.4–9.9)。
  • 女性占78.3%,有手术史者占95.0%;TAR占73.3%。
  • 平均手术时间274.1±99.5分钟(95%CI 248.9–299.3),平均住院3.7±2.3天(95%CI 3.12–4.30),无中转开腹。
  • 仅1例(1.7%)发生Clavien-Dindo IIIa级并发症,3个月随访无复发。

临床怎么用

  • 在具备机器人手术条件的中心,可标准化开展eTEP、TAR及TAPP等成分分离技术修补腹壁疝。
  • 关注术后30天内Clavien-Dindo IIIa级并发症,本队列发生率低但需个体化评估。

局限性

  • 回顾性设计,样本量60例,随访仅3个月,无法评估长期复发率。
  • 仅纳入韩国三家三级医院,外推至其他地区或基层中心需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Robotic component separation techniques have revolutionized complex ventral hernia repair, offering advantages of minimally invasive surgery. However, outcome data from Asian populations remain scarce. This study reports the first multi-center evaluation of robotic component separation techniques in Korea. METHODS: This retrospective multi-center cohort study included 60 patients undergoing robotic ventral hernia repair at three Korean tertiary institutions between January and December 2024. Surgical techniques comprised enhanced total extraperitoneal (eTEP), transversus abdominis release (TAR), and transabdominal preperitoneal (TAPP) approaches. Surgical protocols were standardized across institutions to minimize variability. Primary outcomes were conversion and recurrence rates; secondary outcomes were operative time, hospital length of stay, and 30-day complications graded by the Clavien-Dindo system. RESULTS: The mean age was 53.4 ± 13.6 (95% confidence interval [CI], 49.9-56.8) years, and the mean BMI was 28.5 ± 5.8 (95% CI, 26.9-29.9) kg/m2. Mean hernia width and height were 6.7 ± 3.5 (95% CI, 5.8-7.5) cm and 8.7 ± 5.0 (95% CI, 7.4-9.9) cm, respectively. Most patients were female (78.3%) with prior surgical history (95.0%). Transversus abdominis release (TAR) was the most frequently utilized technique, accounting for 73.3% of all procedures. The mean operative time was 274.1 ± 99.5 (95% CI, 248.9-299.3) minutes, and the mean length of hospital stay was 3.7 ± 2.3 (95% CI, 3.12-4.30) days, with no conversions to open surgery. Only one patient (1.7%) experienced a postoperative complication classified as Clavien-Dindo grade IIIa. At the 3-month follow-up, no recurrences were observed. CONCLUSION: Robotic ventral hernia repair using component separation techniques appeared safe and feasible in Korea. This approach can be successfully implemented across multiple institutions in Korea.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Lee J, Ha TK, Seo KW, et al. Safety and feasibility of robotic component separation for ventral hernia repair: first Korean multi-center experience. Surg Endosc. 2026. PMID: 42547628. doi:10.1007/s00464-026-13102-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。