近红外自体荧光探头与肉眼识别在甲状腺全切术中甲状旁腺检测与功能保护的随机对照试验
这项单中心前瞻性随机试验纳入154例首次甲状腺全切患者,比较PTeye辅助与单纯肉眼识别甲状旁腺的效果。PTeye组识别甲状旁腺均数更高(3.81 vs 2.73,P<0.001),3-4枚原位保留比例更高(98.7% vs 87.0%,P=0.004),误切率更低(5.2% vs 20.8%,P=0.004)。 junior surgeon亚组中PTeye组暂时性甲状旁腺功能减退发生率更低(20.5% vs 55.2%,P<0.001),永久性甲旁减两组相似。
要点
- PTeye辅助可提高甲状旁腺识别数量及原位保留率,并降低误切率。
- junior surgeon使用PTeye时暂时性甲旁减发生率显著低于肉眼识别。
- 两组永久性甲状旁腺功能减退发生率无差异。
核心结论
- PTeye引导的近红外自体荧光可改善甲状旁腺识别和原位保留,并减少暂时性甲状旁腺功能减退,尤其对 junior surgeon,但不影响永久性甲状旁腺功能减退。
研究设计与样本
- 单中心前瞻性随机对照试验,纳入154例首次甲状腺全切患者,PTeye辅助组与肉眼识别组各77例,由2名 senior surgeon和3名 junior surgeon实施手术。
主要发现
- PTeye组识别甲状旁腺均数为3.81,肉眼组为2.73(P<0.001)。
- PTeye组3-4枚甲状旁腺原位保留比例为98.7%,肉眼组为87.0%(P=0.004)。
- PTeye组误切甲状旁腺发生率为5.2%,肉眼组为20.8%(P=0.004)。
- junior surgeon使用PTeye时自体移植率高于 senior surgeon(33.3% vs 10.5%,P=0.015)。
- junior surgeon亚组中,PTeye组暂时性甲状旁腺功能减退发生率为20.5%,肉眼组为55.2%(P<0.001); senior surgeon亚组无差异。
关键数值与推荐
- 女性(P=0.047)、原位保留≤2枚甲状旁腺(P=0.008)及自体移植(P=0.010)预测术后第1天甲状旁腺激素血清水平低。
- 两组永久性甲状旁腺功能减退发生率相似。
临床怎么用
- 在甲状腺全切术中可考虑使用PTeye辅助识别甲状旁腺,尤其 junior surgeon,以提高原位保留并减少暂时性甲旁减。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess whether PTeye-guided identification increases the number of parathyroid glands (PGs) preserved in situ and reduces hypoparathyroidism compared with visual identification alone. BACKGROUND: Injury or inadvertent removal of PGs during thyroidectomy is the main cause of postoperative hypoparathyroidism. Reliance on visual inspection makes intraoperative PG identification difficult. Probe-based near-infrared autofluorescence (NIRAF) systems such as PTeye provide real-time, tissue-specific feedback that may enhance PG detection and preservation. METHODS: In this single-center, prospective, randomized trial, patients undergoing first-time total thyroidectomy were allocated to PTeye-assisted or visual PG identification. Procedures were performed by 2 senior and 3 junior surgeons. The primary outcome was the number of PGs identified. Secondary outcomes included inadvertent parathyroidectomy, autotransplantation, and transient and last follow-up hypoparathyroidism. RESULTS: Among 154 randomized patients (77 per group; mean age 53.4±14.3 y; 84.4% female), PTeye increased the mean number of PGs identified (3.81 vs. 2.73; P <0.001) and the proportion with 3-4 PGs preserved in situ (98.7% vs. 87.0%; P =0.004). Inadvertent parathyroidectomy was less frequent with PTeye (5.2% vs. 20.8%; P =0.004). Junior surgeons performed more autotransplantations than senior surgeons when using PTeye (33.3% vs. 10.5%; P =0.015). Female sex ( P =0.047), ≤2 PGs preserved ( P =0.008), and autotransplantation ( P =0.010) predicted low postoperative day-1 parathormone serum level. Among junior surgeons, transient hypoparathyroidism was lower with PTeye (20.5% vs. 55.2%; P <0.001), with no difference among senior surgeons. Permanent hypoparathyroidism rates were similar between groups. CONCLUSIONS: PTeye-guided NIRAF improves PG identification and in situ preservation and reduces transient hypoparathyroidism, particularly for junior surgeons, without affecting permanent hypoparathyroidism.
引用
- Barczyński M, Pac A, Krakowska K, et al. Near-infrared Autofluorescence Probe Versus Visual Identification for Parathyroid Detection and Functional Preservation During Total Thyroidectomy: A Randomized Controlled Trial. Ann Surg. 2026. PMID: 42638312. doi:10.1097/SLA.0000000000007180
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。