文献速递胃肠外科围术期管理与 ERAS

上消化道实时内镜组织氧饱和度成像:基线值及其与胃空肠吻合口溃疡愈合的关联

Real-time endoscopic tissue oxygen saturation imaging of the upper gastrointestinal tract: baseline values and association with gastrojejunal anastomotic ulcer healing.
PubMed 文献 · Surg Endosc · 2026-08-24

这项前瞻性研究纳入51名成人,包括18例正常胃肠道解剖者、26例无并发症的Roux-en-Y胃旁路术(RYGB)患者和7例确诊胃空肠吻合口(GJA)溃疡的RYGB患者,使用内镜StO2成像系统测量各区域黏膜灌注。结果显示愈合溃疡处StO2显著高于未愈合处(p=0.002),未愈合溃疡StO2明显降低,提示低StO2与溃疡愈合不良相关。

要点

  • 内镜StO2成像可实时定量评估正常及RYGB术后黏膜灌注。
  • GJA溃疡愈合处StO2显著高于未愈合处(p=0.002)。
  • 低StO2或可识别缺血性溃疡,但样本量小需谨慎解读。

核心结论

  • 内镜StO2成像可行,能定量评估正常和RYGB术后解剖的黏膜灌注。
  • GJA溃疡处低StO2与愈合不良相关,可能有助于识别可从早期手术干预中获益的缺血性溃疡。

研究设计与样本

  • 前瞻性研究,共纳入51名成人:18例正常胃肠道解剖,26例无并发症的RYGB解剖,7例确诊GJA溃疡的RYGB患者。
  • 使用内镜StO2成像系统测量食管、胃/小胃囊、十二指肠/空肠及吻合口部位的StO2。
  • 溃疡患者接受最大程度药物治疗并随访内镜复查,比较愈合与未愈合溃疡的StO2值。

主要发现

  • 正常解剖中,食管StO2低于胃和十二指肠,胃与十二指肠相似。
  • 无并发症RYGB患者的小胃囊、吻合口和Roux支StO2值相当。
  • 溃疡愈合处StO2显著高于未愈合处(p=0.002)。
  • 愈合溃疡的StO2接近基线吻合口水平,而未愈合溃疡StO2明显降低。

临床怎么用

  • 内镜StO2成像可作为评估RYGB术后GJA溃疡黏膜灌注的可行工具。
  • 对GJA溃疡患者,低StO2可能提示愈合不良,需考虑更积极干预,但当前证据尚属初步。

局限性

  • 样本量小,尤其溃疡亚组仅7例, findings应视为初步结果并谨慎解读。
  • 需更大规模研究验证StO2阈值及其在RYGB术后临床决策中的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Gastrojejunal anastomotic (GJA) ulcers are a common complication after Roux-en-Y gastric bypass (RYGB) and may be refractory to medical therapy. Impaired mucosal perfusion is suspected to contribute to non-healing ulcers, but no method exists to directly assess ischemia. We evaluated the feasibility of real-time endoscopic tissue oxygen saturation (StO2) imaging to quantify mucosal perfusion and its association with ulcer healing. METHODS: In this prospective study, 51 adults were included: 18 with normal gastrointestinal anatomy, 26 with RYGB anatomy without complications, and a subgroup of 7 RYGB patients with confirmed GJA ulcers. StO2 was measured in the esophagus, stomach/pouch, duodenum/jejunum, and anastomotic sites using an endoscopic StO2 imaging system. Ulcer patients received maximal medical therapy and were reassessed by follow-up endoscopy. StO2 values were compared across regions and between healed and non-healed ulcers. RESULTS: In normal anatomy, esophageal StO2 was lower than gastric and duodenal values, while stomach and duodenum were similar. In RYGB patients without complications, StO2 values were comparable across the pouch, anastomosis, and Roux limb. Among ulcers, healed sites had significantly higher StO2 than non-healed sites (p = 0.002). Healed ulcers exhibited StO2 near baseline anastomotic levels, whereas non-healed ulcers demonstrated markedly reduced StO2. CONCLUSION: Endoscopic StO2 imaging is feasible and enables quantitative assessment of mucosal perfusion in both normal and post-RYGB anatomy. Low StO2 at GJA ulcers is associated with poor healing, highlighting its potential to identify ischemic ulcers that may benefit from early surgical intervention. However, given the small sample size, particularly in the ulcer subgroup, these findings should be considered preliminary and interpreted with caution. Larger studies are needed to validate StO2 thresholds and define its role in clinical decision-making after RYGB.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Leonardo L, Walradt T, Szvarca D, et al. Real-time endoscopic tissue oxygen saturation imaging of the upper gastrointestinal tract: baseline values and association with gastrojejunal anastomotic ulcer healing. Surg Endosc. 2026. PMID: 42637939. doi:10.1007/s00464-026-13153-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。