文献速递围术期管理与 ERAS

Crowe Ⅳ型发育性髋关节发育不良全髋关节置换术的髋臼定位与重建技术

[Total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of the hip acetabular localization and reconstruction techniques].
PubMed 文献 · Zhonghua Wai Ke Za Zhi · 2026-01-01

本研究为回顾性病例系列研究,纳入231例(310髋)Crowe Ⅳ型发育性髋关节发育不良患者,采用后外侧入路全髋关节置换术,术中运用「ABCDE」法定位真实髋臼并进行髋臼重建。术后随访(28.8±14.2)个月,Harris髋关节评分由术前(60.0±14.1)分升至(95.9±3.1)分(P<0.01),下肢长度差异绝对值由术前(17.6±11.2)mm降至(6.5±3.3)mm(P<0.01)。

要点

  • 「ABCDE」法可精准定位Crowe Ⅳ型DDH的真实髋臼。
  • 髋臼重建技术可提升髋臼杯稳定性并改善髋关节功能。
  • 术后髋臼相关并发症6髋,包括脱位3髋和髋臼骨折3髋。

核心结论

  • 采用的髋臼识别方法可精准定位真实髋臼,髋臼重建技术可提升髋臼杯稳定性并改善髋关节功能。

研究设计与样本

  • 回顾性病例系列研究,纳入2018年8月至2024年4月两家中心连续收治的231例(310髋)Crowe Ⅳ型DDH患者,均行后外侧入路全髋关节置换术。
  • 男性17例,女性214例,年龄(43.9±9.8)岁(范围:18~60岁),体重指数(24.0±3.1)kg/m²(范围:17~30 kg/m²)。
  • 术中采用髋臼识别「ABCDE」法定位真实髋臼,并采用髋臼磨锉和髋臼杯植入的髋臼重建技术。

主要发现

  • 手术时间(131.7±27.5)min(范围:91~170 min),术后住院时间(5.2±2.8)d(范围:3~9 d),随访时间(28.8±14.2)个月(范围:12~46个月)。
  • 机器人或导航辅助手术223例,传统手术87例;陶瓷对陶瓷界面195髋,陶瓷对高交联聚乙烯界面114髋,金属对聚乙烯界面1髋;所有髋股骨侧均使用组配式假体,205髋行粗隆下截骨。
  • 髋臼相关并发症6髋,其中脱位3髋、髋臼骨折3髋;二次手术3髋,均为术后脱位行切开复位手术。
  • Harris髋关节评分由术前(60.0±14.1)分(范围:40~74分)升至术后(95.9±3.1)分(范围:88~99分)(t=32.450,P<0.01)。
  • 术后下肢长度差异绝对值(6.5±3.3)mm(范围:0~18 mm)小于术前(17.6±11.2)mm(范围:1~50 mm)(t=9.152,P<0.01)。

临床怎么用

  • 对Crowe Ⅳ型DDH患者行全髋关节置换术时,可采用「ABCDE」法定位真实髋臼并结合标准化髋臼重建技术。
  • 术后需关注髋臼相关并发症,尤其是脱位和髋臼骨折。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To introduce an acetabular reconstruction technique for total hip arthroplasty (THA) in patients with Crowe type Ⅳ developmental dysplasia of the hip (DDH), and report its mid-term clinical outcomes. Methods: This is a retrospective case series study. Clinical data of 231 patients (310 hips) with Crowe type Ⅳ DDH who consecutively underwent THA via the posterolateral approach at the First and the Fourth Medical Centers of the Chinese People's Liberation Army General Hospital from August 2018 to April 2024 were retrospectively analyzed, and all patients had complete surgical and follow-up records. There were 17 males and 214 females, with an age of (43.9±9.8) years (range:18 to 60 years) and a body mass index of (24.0±3.1) kg/m² (range:17 to 30 kg/m²). Intraoperatively, the "ABCDE" method for true acetabulum identification (A: acetabular capsule; B: bone ridge; C: ligamentum capitis femoris; D: detect with index finger; E: exploration via ligamentum transversum) was adopted to precisely locate the true acetabulum, together with standardized operative essentials for acetabular reaming and acetabular cup implantation. All patients were followed up for no less than 1 year postoperatively. Preoperative and postoperative Harris Hip Score (HHS) and leg length discrepancy were measured and recorded, and perioperative complications were documented. The paired-sample t-test was used to compare preoperative and postoperative indicators. Results: All patients successfully received the surgery and completed follow-up. Among all hips, 223 were treated with robotic or navigation-assisted THA, and 87 with conventional THA. The operative time was (131.7±27.5) min (range:91 to 170 min). Intraoperatively, ceramic-on-ceramic bearing surfaces were used in 195 hips, ceramic-on-highly cross-linked polyethylene in 114 hips, and metal-on-polyethylene in 1 hip. Modular femoral stems were implanted in all hips, and subtrochanteric osteotomy was performed in 205 hips. The postoperative hospital stay was (5.2±2.8) d (range:3 to 9 d). The follow-up period was (28.8±14.2) months (range:12 to 46 months). Acetabulum-related complications occurred in 6 hips, including 3 cases of hip dislocation and 3 cases of acetabular fracture; secondary open reduction surgery was performed in 3 hips due to postoperative dislocation. The HHS significantly increased from preoperative (60.0±14.1) points (range:40 to 74 points) to postoperative (95.9±3.1) points (range:88 to 99 points) (t=32.450, P<0.01). The absolute value of postoperative leg length discrepancy was (6.5±3.3) mm (range:0 to 18 mm), which was significantly lower than the preoperative value of (17.6±11.2) mm (range:1 to 50 mm) (t=9.152, P<0.01). Conclusion: The true acetabulum localization and acetabular reconstruction technique adopted in this study can accurately identify the native acetabulum, improve the stability of the acetabular component, and significantly restore hip function, which provides certain clinical references for acetabular reconstruction in patients with Crowe type Ⅳ DDH. 目的: 探讨全髋关节置换术(THA)中利用髋臼定位方法和重建技术治疗Crowe Ⅳ型发育性髋关节发育不良(DDH)的中期临床疗效。 方法: 本研究为回顾性病例系列研究。回顾性分析2018年8月至2024年4月解放军总医院第一医学中心和解放军总医院第四医学中心连续收治的行后外侧入路THA的231例(310髋)Crowe Ⅳ型DDH患者的临床资料。男性17例,女性214例,年龄(43.9±9.8)岁(范围:18~60岁),体重指数(24.0±3.1)kg/m2(范围:17~30 kg/m2)。术中采用髋臼识别“ABCDE”法(A:髋关节囊;B:骨嵴;C:圆韧带;D:食指探查;E:横韧带)定位真实髋臼位置,并采用髋臼磨锉和髋臼杯植入的髋臼重建技术。患者术后随访1年以上,记录手术前后髋关节Harris评分(HHS),测量下肢长度差异,并记录并发症情况。手术前后各指标的比较采用配对样本t检验。 结果: 所有患者顺利完成髋臼重建。其中机器人或导航辅助手术223例,传统手术87例,手术时间(131.7±27.5)min(范围:91~170 min)。术中195髋使用陶瓷对陶瓷假体界面,114髋使用陶瓷对高交联聚乙烯假体界面,1髋使用陶瓷对高分子聚乙烯假体界面。所有髋关节的股骨侧均使用组配式假体,其中205例行粗隆下截骨。术后住院时间(5.2±2.8)d(范围:3~9 d)。术后随访时间为(28.8±14.2)个月(范围:12~46个月)。共6髋发生髋臼处手术并发症,其中脱位3髋,髋臼骨折3髋;二次手术3髋,均为术后脱位行切开复位手术。患者HHS由术前的(60.0±14.1)分(范围:40~74分)升至(95.9±3.1)分(范围:88~99分),差异有统计学意义(t=32.450,P<0.01)。术后双下肢长度差的绝对值为(6.5±3.3)mm(范围:0~18 mm),小于术前的(17.6±11.2)mm(范围:1~50 mm),差异有统计学意义(t=9.152,P<0.01)。 结论: 本研究采用的髋臼识别方法可精准定位真实髋臼,髋臼重建技术可提升髋臼杯稳定性,改善髋关节功能,为Crowe Ⅳ型DDH患者的髋臼重建提供了一定的临床参考。.

来源:Zhonghua Wai Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Huang YJ, Li MF, Wang G, et al. [Total hip arthroplasty for Crowe type Ⅳ developmental dysplasia of the hip acetabular localization and reconstruction techniques]. Zhonghua Wai Ke Za Zhi. 2026. PMID: 42509217. doi:10.3760/cma.j.cn112139-20260317-00110

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。