文献速递围术期管理与 ERAS

磁锚定辅助与传统电视辅助胸腔镜肺切除术的安全性与有效性:随机对照试验

Safety and efficacy of magnetic-anchoring vs conventional video-assisted thoracoscopic surgery (VATS) lung resection: a randomized controlled trial.
PubMed 文献 · Surg Endosc · 2026-07-17

单中心随机对照试验纳入40例肺切除术患者,随机分为磁锚定辅助VATS组(20例)和传统VATS组(20例)。两组术野暴露效果、术中副损伤及围术期恢复指标均无显著差异,但磁锚定组外科医生满意度评分显著更高,且需要两名助手的病例更少。磁锚定辅助VATS肺切除术与传统VATS同样安全有效。

要点

  • 磁锚定辅助VATS术野暴露效果与传统VATS无显著差异(p=0.115)。
  • 磁锚定组外科医生满意度评分显著更高(p=0.003)。
  • 磁锚定组需要两名助手的病例显著减少(p=0.006)。

核心结论

  • 磁锚定辅助VATS肺切除术与传统VATS同样安全有效。

研究设计与样本

  • 单中心随机对照试验,纳入40例拟行肺切除术患者,随机分为磁锚定辅助VATS组(A组,n=20)和传统VATS组(B组,n=20)。

主要发现

  • 术野暴露效果分级(优、满意、一般、差):A组15、4、1、0例,B组17、2、1、0例,p=0.115。
  • 术中副损伤分级(无、轻、中、重):A组13、6、1、0例,B组9、6、3、2例,p=0.304。
  • 手术时间(p=0.136)、术中出血量(p=0.380)、术后引流管拔除时间(p=0.180)、拔管时间(p=0.529)、下床活动时间(p=0.260)、总住院时间(p=0.685)及术后住院时间(p=0.305)均无显著差异。
  • 外科医生满意度评分A组显著更高(p=0.003)。
  • A组需要两名助手的病例显著少于B组(p=0.006)。

临床怎么用

  • 磁锚定辅助VATS可作为传统VATS的可行替代,在不增加风险的前提下提高术者满意度并减少助手需求。

局限性

  • 单中心小样本(40例)研究,随访仅1个月,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Video-assisted thoracic surgery (VATS) is the preferred approach for lung resection. Magnetic anchoring technology (MAT) utilizes magnetic forces for organ retraction and improves surgical field exposure. This trial aimed to evaluate the safety and efficacy of MAT-assisted VATS for lung resection. METHODS: This single-center randomized controlled trial (registered at the Chinese Clinical Trial Registry, ChiCTR2000029676) enrolled 40 patients scheduled for lung resection and randomly assigned them to MAT-assisted VATS (Group A, n = 20) or conventional VATS (Group B, n = 20). The primary outcomes included surgical field exposure efficacy, intraoperative collateral injuries, and operator-related adverse events. Secondary outcomes included surgeon satisfaction score, number of assistants, and perioperative recovery metrics with a 1-month postoperative follow-up. RESULTS: Surgical field exposure efficacy (graded as Excellent, Satisfactory, Normal, and Poor) was as follows: Group A, 15, 4, 1, and 0 cases; and Group B, 17, 2, 1, and 0 cases (p = 0.115). Intraoperative collateral injuries (graded as None, Mild, Moderate, and Severe) were as follows: Group A, 13, 6, 1, and 0 cases; Group B, 9, 6, 3, and 2 cases (p = 0.304). No significant differences were observed in the operative time (p = 0.136), intraoperative blood loss (p = 0.380), postoperative drainage tube removal time (p = 0.180), time to extubation (p = 0.529), time to ambulation (p = 0.260), total hospitalization duration (p = 0.685), or postoperative hospitalization duration (p = 0.305). Surgeon satisfaction score was significantly higher in Group A (p = 0.003). Moreover, MAT use markedly reduced dependence on surgical assistants, with fewer cases requiring two assistants in Group A (p = 0.006). The magnetic anchoring devices demonstrated seamless operability, with no adverse events reported during postoperative follow-up. CONCLUSIONS: MAT-assisted VATS lung resection is as effective and safe as conventional VATS.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Yu C, Wang T, Chen N, et al. Safety and efficacy of magnetic-anchoring vs conventional video-assisted thoracoscopic surgery (VATS) lung resection: a randomized controlled trial. Surg Endosc. 2026. PMID: 42467192. doi:10.1007/s00464-026-13161-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。