文献速递疝与腹壁外科胃肠外科

剑突下切口疝:手术入路是否重要?基于ACHQC数据库的分析

Subxiphoid hernias: does surgical approach matter? An analysis of the ACHQC database.
PubMed 文献 · Surg Endosc · 2026-07-07

主要结局为1年复发率,开腹为9.0%、腹腔镜为26.3%、机器人修补为4.3%(p=0.01)。多因素分析仅CDC伤口分级4级与复发风险增加相关(p=0.004)。

要点

  • 腹腔镜剑突下切口疝修补1年复发率最高(26.3%),机器人修补最低(4.3%)。
  • 筋膜闭合率开腹94.2%、腹腔镜55.8%、机器人92.5%(p<0.001)。
  • 多因素分析仅CDC伤口分级4级与复发风险增加独立相关(p=0.004)。

核心结论

  • 腹腔镜剑突下切口疝修补的1年复发率最高,其次为开腹,机器人修补最低。
  • 导致该差异的因素尚不明确,需更多研究进一步探讨。

研究设计与样本

  • 回顾性分析Abdominal Core Health Quality Collaborative数据库2014至2024年数据。
  • 纳入仅涉及中线1(M1)或中线1和2(M1-2)缺损的切口疝修补患者。
  • 采用多因素logistic回归评估复发危险因素,主要结局为1年复发。

主要发现

  • 三组在年龄、种族、BMI、ASA分级和疝宽度方面相似。
  • 补片放置率为95.6%,补片位置随手术入路不同而变化(p<0.001)。
  • 筋膜闭合率开腹94.2%、腹腔镜55.8%、机器人92.5%(p<0.001)。
  • 1年复发率开腹9.0%、腹腔镜26.3%、机器人4.3%(p=0.01)。
  • 多因素分析仅CDC伤口分级4级与复发风险增加相关(p=0.004)。

关键数值与推荐

  • 1年复发率:开腹9.0%,腹腔镜26.3%,机器人4.3%(p=0.01)。
  • 筋膜闭合率:开腹94.2%,腹腔镜55.8%,机器人92.5%(p<0.001)。
  • 补片放置率95.6%,补片位置随手术入路不同而变化(p<0.001)。
  • CDC伤口分级4级与复发风险增加独立相关(p=0.004)。

临床怎么用

  • 针对剑突下切口疝,机器人修补可能降低1年复发率,但需更多研究验证。
  • 腹腔镜修补与较高的1年复发率相关,选择该入路时应审慎评估。
  • CDC伤口分级4级患者复发风险较高,围术期应加强关注。

局限性

  • 本研究为回顾性分析,存在选择偏倚等固有局限。
  • 导致不同入路复发率差异的因素尚不明确。
  • 需更多研究进一步探讨该差异的原因。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Subxiphoid incisional hernias (SIH) are challenging to repair with recurrence rates ranging from 10 to 43%. There is a paucity of data regarding the optimal repair method and a small amount of early data on robotic SIH repair. The purpose of this study was to compare how surgical approach-open, laparoscopic, and robotic-affects clinical outcomes. METHODS: A retrospective analysis of the Abdominal Core Health Quality Collaborative was performed from 2014 to 2024. Patients undergoing incisional hernia repair involving only midline 1 (M1) or midline 1 and 2 (M1-2) defects were included. Demographic data, operative details, and clinical outcomes were collected and compared by surgical approach. Multivariable logistic regression was completed to evaluate risk variables for recurrence. The primary outcome was 1-year recurrence. RESULTS: Eight hundred fifty-eight patients met study criteria including 499 open, 104 laparoscopic, and 255 robotic repairs. The groups were similar in age, race, BMI, ASA Class, and hernia width. Mesh was placed in 95.6% of cases with location varying by surgical approach (p < 0.001). Fascial closure rates were 94.2, 55.8, and 92.5% for open, laparoscopic, and robotic repairs respectively (p < 0.001). The 1-year recurrence rate was 9.0% in open repairs, 26.3% in laparoscopic repairs, and 4.3% in robotic repairs (p = 0.01). On multivariable analysis, only CDC Wound Class 4 conveyed an increased risk of recurrence (p = 0.004). CONCLUSION: In this study, laparoscopic SIH repair had the highest 1-year recurrence rate followed by open and robotic repairs. The contributing factors for this remain elusive, and more studies need to be completed in this regard.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Farran A, Budney S, Kleppe K, et al. Subxiphoid hernias: does surgical approach matter? An analysis of the ACHQC database. Surg Endosc. 2026. PMID: 42414774. doi:10.1007/s00464-026-13030-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。