腹腔内食管长度与腹腔镜食管旁疝修补术后复发的关系
该回顾性研究分析了183例腹腔镜食管旁疝修补术患者,术中最大程度游离后测量腹腔内食管长度,中位值为4.0 cm,6个月影像学复发率为8.2%。多因素分析未发现腹腔内食管长度与复发存在统计学显著关联(aOR 1.48,95%CI 0.62-3.59,p=0.38),提示追求更长食管长度可能并非更优。
要点
- 腹腔内食管长度与6个月复发无显著关联,aOR 1.48(95%CI 0.62-3.59)。
- 将长度按≤3 cm vs >3 cm或≤4 cm vs >4 cm分组,结果稳健。
- 食管游离应视为连续过程而非追求特定目标长度。
核心结论
- 腹腔镜食管旁疝修补术中,腹腔内食管长度与6个月影像学复发无统计学显著关联。
- 追求尽可能多的腹腔内食管长度这一常见做法可能受到质疑。
- 作者建议将食管游离视为连续过程而非目标,更多未必更好。
研究设计与样本
- 共分析183例患者,中位年龄68岁,女性占76%。
- 术中由手术医生在最大程度食管游离后前瞻性测量腹腔内食管长度。
- 采用多因素logistic回归分析腹腔内食管长度与6个月影像学复发及术后并发症的关联,并校正临床和社会人口学因素。
主要发现
- 腹腔内食管长度中位值为4.0 cm(IQR 3.5-4.0 cm)。
- 6个月影像学复发率为8.2%。
- 腹腔内食管长度与6个月复发无统计学显著关联(aOR 1.48,95%CI 0.62-3.59,p=0.38)。
- 敏感性分析(≤3 cm vs >3 cm;≤4 cm vs >4 cm)结果稳健。
- 术中99%病例行胃底折叠术,54%使用补片,16%行松弛切口。
临床怎么用
- 腹腔镜食管旁疝修补术中,不必强求达到某一特定腹腔内食管长度。
- 应将食管游离视为连续变量,根据术中情况个体化处理。
- 需等待进一步研究验证,当前结果提示更多长度未必降低复发。
局限性
- 回顾性研究设计。
- 单中心三级医疗中心数据。
- 样本量183例,复发事件较少。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Recurrence of hiatal hernia after paraesophageal hernia repair (PEHR) affects many patients, and axial tension is thought to be a major factor. A widely accepted guideline is that extensive esophageal mobilization to achieve at least 3 cm of intra-abdominal esophageal length is important, and more length may further reduce recurrence, but there are minimal data to support this. We aimed to analyze the relationship between intra-abdominal esophageal length and recurrence in patients undergoing laparoscopic PEHR. METHODS: We conducted a retrospective study of adult patients undergoing laparoscopic paraesophageal hernia repair at a tertiary care institution from October 1, 2015, through January 31, 2024. Intra-abdominal esophageal length (EL) was measured prospectively by the operative surgeon after maximal esophageal mobilization. We investigated associations of intra-abdominal EL with radiographic recurrence at 6 months, as well as with postoperative complications, using multivariable logistic regression adjusted for clinical and sociodemographic factors. RESULTS: 183 patients were analyzed, with a median age of 68 years and 76% were female. During PEHR, a fundoplication was performed in 99% of cases, mesh was used in 54%, and a relaxing incision was performed in 16%. The median intra-abdominal EL was 4.0 cm (IQR 3.5-4.0 cm). Recurrence occurred in 8.2% of patients. Overall, there was no statistically significant association between intra-abdominal EL and recurrence at 6 months (adjusted Odds Ratio aOR 1.48, 95% CI 0.62-3.59, p = 0.38). This finding was robust to sensitivity analyses, including grouping intra-abdominal EL of < = 3 cm compared with > 3 cm and EL of < = 4 cm compared with > 4 cm. CONCLUSIONS: The common practice to achieve as much intra-abdominal esophageal length as possible during PEHR may be questioned by these findings. Pending further studies, we propose that esophageal mobilization be viewed as more of a continuum than a target, recognizing that more may not be better.
引用
- Zhang IY, Tangalakis L, Hsiao V, et al. "Is more better?": association of intra-abdominal esophageal length in laparoscopic paraesophageal hernia repair with recurrent hiatal hernia. Surg Endosc. 2026. PMID: 42301455. doi:10.1007/s00464-026-12809-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。