机器人远端胰腺切除术中胰腺残端四重加固技术
这项前瞻性研究纳入44例连续机器人远端胰腺切除术患者,比较四重加固组(n=27)与对照组(n=17)的结局。四重加固技术包括吻合器线加固、可吸收加固毡、3-0不可吸收双针单丝U形缝合及喷涂纤维蛋白密封胶。结果显示加固组临床相关术后胰瘘(CR-POPF)发生率显著降低(3.7% vs. 41.2%,P=0.002),≥Clavien-Dindo IIIa级并发症更少(0% vs. 23.5%,P=0.004),中位住院时间更短(5.0 vs. 7.0天,P=0.007)。
要点
- 四重加固技术可显著降低机器人远端胰腺切除术后临床相关胰瘘发生率。
- 加固组严重并发症(≥Clavien-Dindo IIIa级)发生率显著低于对照组。
- 加固组中位住院时间较对照组缩短2天,且两组均无30天再手术或90天死亡。
核心结论
- 四重加固技术是安全可行的策略,可显著降低机器人远端胰腺切除术后临床相关胰瘘和重大并发症。
研究设计与样本
- 前瞻性研究,纳入2020年3月至2025年9月连续44例机器人远端胰腺切除术患者,四重加固组27例,对照组17例。
主要发现
- 加固组临床相关术后胰瘘发生率为3.7%,对照组为41.2%(P=0.002)。
- 加固组≥Clavien-Dindo IIIa级并发症发生率为0%,对照组为23.5%(P=0.004)。
- 加固组中位住院时间为5.0天,对照组为7.0天(P=0.007)。
- 两组均无30天再手术或90天死亡。
- 两组胰腺质地具有可比性。
关键数值与推荐
- 临床相关术后胰瘘按2016年ISGPS标准定义。
- 四重加固技术包括:吻合器线加固、可吸收加固毡、3-0不可吸收双针单丝U形缝合、喷涂纤维蛋白密封胶。
临床怎么用
- 在机器人远端胰腺切除术中,可采用四重加固技术处理胰腺残端以降低临床相关胰瘘风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Postoperative pancreatic fistula (POPF) remains a significant challenge in robotic distal pancreatectomy (RDP). We developed a novel "quadruple reinforcement technique" to mitigate this risk and evaluated its clinical efficacy compared to conventional techniques. METHODS: In this prospective study of 44 consecutive RDP patients (March 2020-September 2025), outcomes were compared between a quadruple reinforcement group (n = 27) and a control group (n = 17). The reinforcement technique involved: (1) staple line reinforcement; (2) absorbable reinforcement felt; (3) U-shaped sutures using a 3-0 non-absorbable double-armed monofilament; and (4) sprayed fibrin sealant. Clinically relevant POPF (CR-POPF) was defined per 2016 ISGPS criteria. RESULTS: Pancreatic texture was comparable between the groups. The quadruple reinforcement group demonstrated a significantly lower incidence of CR-POPF (3.7% vs. 41.2%, P = 0.002) and fewer complications ≥ Clavien-Dindo grade IIIa (0% vs. 23.5%, P = 0.004) compared to controls. Median hospital stay was significantly shorter in the reinforcement group (5.0 vs. 7.0 days, P = 0.007). There were no 30-day reoperations or 90-day mortalities in either group. CONCLUSIONS: The quadruple reinforcement technique is a safe and feasible strategy that significantly reduces CR-POPF and major complications. This systematic combination effectively optimizes postoperative outcomes in RDP.
引用
- Abe S, Kawaguchi Y, Ito K, et al. Quadruple reinforcement technique for pancreatic stump during robotic distal pancreatectomy. Surg Endosc. 2026. PMID: 42257931. doi:10.1007/s00464-026-12744-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。