结肠镜辅助预置引导管用于复杂改道解剖患者ERCP的研究
这项回顾性研究纳入2021至2024年101例复杂改道解剖患者,比较单气囊小肠镜辅助ERCP(SBEAE)与长结肠镜辅助ERCP(LCAE)的疗效。LCAE组在插管成功率(94.8% vs 79.1%,p=0.077)和整体操作成功率(89.7% vs 60.5%,p<0.001)上均优于SBEAE组,且操作时间更短(57.6±23.4 vs 70.5±19.7 min,p<0.001)。
要点
- LCAE整体操作成功率89.7%,显著高于SBEAE的60.5%(p<0.001)。
- LCAE平均操作时间57.6±23.4 min,短于SBEAE的70.5±19.7 min(p<0.001)。
- LCAE组插管失败20例中,经十二指肠镜再插管成功率达90%和94.4%。
核心结论
- 对于复杂改道解剖患者,由经验丰富的内镜医师操作时,该技术有效且安全。
- LCAE在內镜插管和胆胰管插管方面优于SBEAE。
研究设计与样本
- 回顾性研究,纳入2021至2024年复杂改道解剖行ERCP患者101例。
- 分SBEAE组43例(42.6%)和LCAE组58例(57.4%),平均年龄60.95±12.9岁,男性61例。
主要发现
- SBEAE与LCAE插管成功率分别为79.1%(34/43)和94.8%(55/58),p=0.077。
- 整体操作成功率分别为60.5%(26/43)和89.7%(52/58),p<0.001。
- 平均操作时间分别为70.5±19.7 min和57.6±23.4 min,p<0.001。
- LCAE组插管失败20例后经十二指肠镜再插管,插管率和成功率分别为90%和94.4%,平均操作时间83.5±21.1 min。
关键数值与推荐
- LCAE组胆胰管插管失败时,经工作通道置入塑料引导管至靶点附近,退出结肠镜后保留引导管,再进侧视十二指肠镜重新插管。
临床怎么用
- 复杂改道解剖患者ERCP可优先考虑LCAE,以提高插管和操作成功率并缩短时间。
- LCAE插管失败时,可预置引导管后改用十二指肠镜再尝试。
局限性
- 回顾性研究设计。
- 技术需双操作者配合且由经验丰富内镜医师完成。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Balloon-assisted enteroscopy is limited by a small working channel and few compatible accessories. Herein, we assessed a novel endoscopic retrograde cholangiopancreatography (ERCP) involving a long-type single-balloon enteroscope (200 cm length; 2.8 mm channel), requiring dual-operator manipulation. Although standard in our centre, this technique's clinical limitations compared to single-operator long-colonoscopy ERCP remain unclear. METHODS: This retrospective study enrolled patients with complex surgically altered anatomy who underwent ERCP from 2021 to 2024, divided into the single-balloon enteroscopy-assisted ERCP (SBEAE) and long colonoscopy-assisted ERCP (LCAE) groups. The target site (i.e. native papilla or surgical anastomosis) was reached using a 'push and pull' method. In cases of failed biliopancreatic duct cannulation in the LCAE group, a plastic guide tube was inserted via the working channel with the distal end placed near the target site. The colonoscope was withdrawn, with the guide tube left in situ; a side-viewing duodenoscope was then advanced to reattempt cannulation. Biliary duct cannulation and overall procedure success rates were assessed. RESULTS: Overall, 101 patients [SBEAE: 43 (42.6%) and LACE: 58 (57.4%)] were included (mean age: 60.95 ± 12.9 years; male, n = 61), with Roux-en-Y anastomosis (n = 67; 66.3%), Billroth-II gastrectomy with Braun anastomosis (n = 18; 17.8%), and pancreaticoduodenectomy (n = 16; 15.9%). Indications for ERCP included biliary tract (83.2%) and pancreatic (16.8%) diseases. Intubation by SBE and colonoscopy was successful in 34 (79.1%)/55 (94.8%) in the SBEAE/LCAE groups, respectively (p = 0.077), with mean procedure times of 70.5 ± 19.7 and 57.6 ± 23.4 min (p < 0.001). Overall procedural success, defined as successful cannulation and completion of the intended intervention, was achieved in 26 (60.5%) and 52 (89.7%) patients, respectively (p < 0.001). Intubation and cannulation rates via subsequent duodenoscopy were 90% and 94.4%, respectively, (mean procedure time: 83.5 ± 21.1 min) after failed cannulation (n = 20) in the LCAE group. CONCLUSIONS: Our technique is effective and safe for patients with a complex surgically altered anatomy when performed by experienced endoscopists, showing superior endoscopic intubation and biliopancreatic duct cannulation compared to SBEAE.
引用
- Xie L, Zheng Y, He Q, et al. Colonoscopy-assisted preplacement of guide tube for endoscopic retrograde cholangiopancreatography in patients with complex surgically altered anatomy. Surg Endosc. 2026. PMID: 42257974. doi:10.1007/s00464-026-12812-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。