文献速递胃肠外科围术期管理与 ERAS

透视参数在胃袖状胃切除术后狭窄诊断与定量评估中的应用

Fluoroscopic parameters in the diagnosis and quantitative assessment of gastric sleeve stenosis.
PubMed 文献 · Surg Endosc · 2026-05-05

本研究回顾性分析单中心前瞻性数据库的63例疑似胃袖状胃狭窄(GSS)内镜评估患者,测量透视下切迹宽度和近远端袖状胃夹角,并与内镜狭窄分级及阻抗平面测量球囊直径进行相关性分析。结果显示切迹宽度随内镜狭窄严重程度增加而减小(p<0.001),且与阻抗平面测量球囊直径相关(均p<0.05),而夹角与内镜成角分级无显著相关(p=0.21)。透视分析可支持内镜对狭窄严重程度的判断,并补充阻抗平面测量。

要点

  • 透视下切迹宽度随内镜狭窄分级加重而减小,可辅助定量评估GSS。
  • 切迹宽度与阻抗平面测量球囊直径相关,可作为补充测量手段。
  • 袖状胃近远端夹角与内镜成角分级无显著相关,单独应用价值有限。

核心结论

  • 透视分析支持内镜对GSS狭窄严重程度的判断,并补充阻抗平面测量,为GSS诊断提供更广泛可用的方法。

研究设计与样本

  • 单中心前瞻性数据库的回顾性分析,纳入63例因疑似GSS接受内镜评估的患者。

主要发现

  • 按内镜狭窄分级,切迹宽度均值±标准差分别为无狭窄17.1±6.5 mm、轻度13.1±5.1 mm、中度12.4±2.6 mm、重度8.6±2.1 mm(p<0.001)。
  • 按内镜成角分级,近远端夹角均值±标准差分别为无成角101±29度、轻度80±28度、中度76±22度、重度68±20度(p=0.21)。
  • 切迹宽度与阻抗平面测量球囊直径相关(均p<0.05)。

关键数值与推荐

  • 内镜狭窄严重程度由培训有素的减重内镜医师系统评估,依据切迹水平是否存在狭窄及成角。
  • 透视下测量切迹宽度及近远端袖状胃夹角。
  • 阻抗平面测量在不同球囊体积下获取球囊直径,并与切迹宽度进行相关性分析。

临床怎么用

  • 对疑似GSS患者,可在内镜评估时结合透视测量切迹宽度,辅助判断狭窄严重程度。
  • 透视切迹宽度可作为阻抗平面测量的补充,尤其在不具备阻抗平面测量条件时。

局限性

  • 回顾性分析,单中心,样本量63例,结论需外推验证。
  • 内镜成角分级与透视夹角无显著相关,提示该参数单独应用价值有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The diagnosis of gastric sleeve stenosis (GSS) is often delayed due to the lack of readily available objective criteria. The aim of this study was to assess whether fluoroscopic parameters obtained during endoscopy may offer a widely available method to assess GSS. METHODS: This was a retrospective analysis of a single-institution, prospective database of patients who underwent endoscopic evaluation of suspected GSS. Endoscopic severity of GSS, defined by the presence of stenosis and angulation at the level of the incisura, was systemically assessed by a trained bariatric endoscopist. The width of the incisura and angle between the proximal and distal sleeve were measured fluoroscopically. Balloon diameter measurements were obtained at different balloon volumes during impedance planimetry testing and correlated with incisura width. RESULTS: A total of 63 procedures were included. When stratified by endoscopic impression of stenosis, the mean (± standard deviation) width of the incisura in patients with no stenosis was 17.1 ± 6.5 mm, mild stenosis was 13.1 ± 5.1 mm, moderate stenosis was 12.4 ± 2.6 mm, and severe stenosis was 8.6 ± 2.1 mm (p < 0.001). When stratified by endoscopic impression of angulation, the mean (± standard deviation) width of patients with no angulation was 101 ± 29 degrees, mild angulation was 80 ± 28 degrees, moderate angulation was 76 ± 22 degrees, and severe angulation was 68 ± 20 degrees (p = 0.21). The width of the incisura correlated with balloon diameter on impedance planimetry (all p < 0.05). CONCLUSIONS: Fluoroscopic analysis in GSS supports endoscopic impressions of stenosis severity and complements impedance planimetry measurements. This approach offers a more widely available method for diagnosis of GSS.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Tanner S, Min S, Yu JX, et al. Fluoroscopic parameters in the diagnosis and quantitative assessment of gastric sleeve stenosis. Surg Endosc. 2026. PMID: 42257971. doi:10.1007/s00464-026-12810-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。