文献速递甲状腺与颈部外科

自体荧光异质性指数用于术中鉴别异常与正常甲状旁腺

Autofluorescence can aid in differentiating normal from pathologic parathyroid glands during parathyroidectomy.
PubMed 文献 · Surgery · 2026-05-18

本研究纳入72例因经典或正常激素型原发性甲状旁腺功能亢进接受治愈性甲状旁腺切除术的患者,用近红外自体荧光设备检测所有已识别甲状旁腺,计算异质性指标(变异性与自体荧光指数)。病理腺体的自体荧光变异性与自体荧光指数显著更高,单腺瘤中自体荧光指数≥2.4、四腺增生中≥2.5更可能为病理腺体。

要点

  • 自体荧光指数可实时定量反映甲状旁腺异质性,辅助鉴别功能亢进与正常腺体。
  • 单腺瘤中自体荧光指数≥2.4更可能为病理腺体,四腺增生中≥2.5更可能为病理腺体。
  • 自体荧光指数与腺体重量无相关性。

核心结论

  • 自体荧光指数提供术中定量测量甲状旁腺异质性的方法,可实时帮助区分功能亢进与正常甲状旁腺。
  • 自体荧光指数≥2.5强烈提示甲状旁腺为腺瘤或增生。

研究设计与样本

  • 单中心研究,纳入72例因经典或正常激素型原发性甲状旁腺功能亢进接受治愈性甲状旁腺切除术的患者。
  • 用近红外自体荧光设备检测所有已识别甲状旁腺,获取每枚腺体的最小与最大自体荧光值。
  • 计算两种异质性指标:变异性(最大值减最小值)与自体荧光指数(最大值/最小值比值)。
  • 采用受试者工作特征分析寻找区分正常与病理腺体的自体荧光指数阈值。

主要发现

  • 研究纳入72例患者,通过治疗57例单腺瘤、5例双腺瘤和10例四腺增生病例实现治愈。
  • 病理腺体的自体荧光变异性与自体荧光指数显著更高。
  • 单腺瘤病例中,自体荧光指数≥2.4的腺体统计学上更可能为病理腺体(曲线下面积=0.90)。
  • 四腺增生病例中,自体荧光指数≥2.5的腺体更可能为病理腺体(曲线下面积=0.86)。
  • 自体荧光指数与腺体重量无相关性。

关键数值与推荐

  • 单腺瘤:自体荧光指数≥2.4更可能为病理腺体(曲线下面积=0.90)。
  • 四腺增生:自体荧光指数≥2.5更可能为病理腺体(曲线下面积=0.86)。
  • 自体荧光指数≥2.5强烈提示腺体为腺瘤或增生。

临床怎么用

  • 在难以区分正常与功能亢进甲状旁腺的病例中,术者可参考自体荧光指数辅助判断。
  • 可结合自体荧光指数阈值(单腺瘤≥2.4、四腺增生≥2.5)辅助识别病理腺体。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Several studies suggest that during parathyroidectomy near-infrared autofluorescence may be able to help differentiate hyperfunctional from normal parathyroid glands. However, to date, no clear metric for employing autofluorescence in this manner in real-time during surgery has been described. This study investigated whether a specific measure of autofluorescence heterogeneity can aid discrimination of pathologic from normal parathyroid glands. METHODS: In patients undergoing curative parathyroidectomy for classic or normohormonal primary hyperparathyroidism, a near-infrared autofluorescence device interrogated all identified parathyroid glands. Minimum and maximum autofluorescence values were obtained for each gland to calculate 2 measures of heterogeneity: variability (maximum minus minimum) and autofluorescence index (maximum/minimum ratio). Receiving operating characteristic analysis was performed to try to identify an autofluorescence index threshold to differentiate normal from pathologic glands. RESULTS: The study included 72 patients. Cure was achieved by treating 57 single adenomas, 5 double adenomas, and 10 cases of 4-gland hyperplasia. Pathologic glands demonstrated significantly higher autofluorescence variability and autofluorescence index. In cases of single adenomas, a gland with autofluorescence index ≥2.4 was statistically more likely to be pathologic (area under the curve = 0.90). In 4-gland hyperplasia, glands with autofluorescence index ≥2.5 were more likely to be pathologic (area under the curve = 0.86). Autofluorescence index and gland weight were not correlated. CONCLUSION: Autofluorescence index provides a quantitative, intraoperative measure of parathyroid gland heterogeneity that can help differentiate hyperfunctional from normal parathyroid glands in real time. An autofluorescence index ≥2.5 strongly suggests that a parathyroid gland is adenomatous or hyperplastic. Surgeons may use this information in any case in which distinguishing between normal and hyperfunctional glands is challenging.

来源:Surgery,查看原文。版权归原作者所有。

引用

  1. Larrabee KA, Jassal J, Springer K, et al. Autofluorescence can aid in differentiating normal from pathologic parathyroid glands during parathyroidectomy. Surgery. 2026. PMID: 42150279. doi:10.1016/j.surg.2026.110203

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。