负压测压可视化技术用于Veress针安全入腹的逐步演进与临床适用性
该回顾性研究评估负压测压可视化(NPMV)及四钳技术(NPMV4)在Veress针腹腔入路中的效果。标准体重疝修补队列中NPMV组注气时间显著缩短(中位1.0 vs 2.0 min,p<0.001),肥胖袖状胃切除队列中四钳组穿刺失败率更低(3% vs 15%)且穿刺次数更少(中位1.0 vs 3.5,p=0.019)。
要点
- NPMV以测压显示替代盐水柱,不增加入路相关并发症且提高操作效率
- 肥胖患者采用NPMV4可减少穿刺失败与穿刺次数,不增加气体相关并发症
- 该系列改良为Veress针入腹提供了简单、可重复且可靠的方法
核心结论
- 以测压显示替代盐水柱未增加入路相关并发症并改善操作效率。
- NPMV4技术进一步提高肥胖患者腹腔镜入路的可靠性。
研究设计与样本
- 回顾性研究,标准体重队列475例腹腔镜腹股沟疝修补(243例NPMV,232例NPV)。
- 肥胖队列53例腹腔镜袖状胃切除(33例四钳,20例两钳)。
主要发现
- 标准体重队列两组气腹成功率均为99%,并发症与穿刺次数无差异。
- NPMV组注气时间显著缩短(中位1.0 vs 2.0 min,p<0.001)。
- 肥胖队列四钳组穿刺失败率3% vs 15%,穿刺次数中位1.0 vs 3.5(p=0.019)。
- 肥胖队列四钳组未增加气体相关并发症。
关键数值与推荐
- NPMV中Veress针连接带测压显示的注气机,压力≤-2 mmHg确认进入腹腔。
临床怎么用
- 标准体重患者可用NPMV替代盐水柱法以缩短注气时间。
- 肥胖患者可考虑NPMV4技术以提高入腹可靠性。
局限性
- 回顾性研究设计。
- 肥胖队列样本量较小(53例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Safe establishment of pneumoperitoneum is essential in laparoscopic surgery because most access-related injuries occur during peritoneal entry. In Veress needle procedures, this step is performed blindly, and conventional verification tests are subjective and often unreliable. The negative pressure-based visualization (NPV) technique enables real-time confirmation of peritoneal entry using a saline column. We therefore developed a manometric modification (NPMV) and a four-forceps technique (NPMV4) to improve practicality and applicability in obese patients. METHODS: This retrospective study included two cohorts: a standard-weight cohort of 475 patients undergoing laparoscopic groin hernia repair (243 NPMV, 232 NPV) and an obese cohort of 53 patients undergoing laparoscopic sleeve gastrectomy (33 four-forceps, 20 two-forceps). In the NPMV, the Veress needle was connected to an insufflator with a manometric display, and peritoneal entry was confirmed at a pressure of minus 2 mmHg or lower. Primary outcomes were pneumoperitoneum success and access-related complications; secondary outcomes included access time and puncture attempts. RESULTS: In the standard-weight cohort, pneumoperitoneum success was 99% in both groups, with no differences in complications or puncture attempts. The NPMV group achieved a significantly shorter time to insufflation (median 1.0 vs 2.0 min, p < 0.001). In the obese cohort, the four-forceps group showed fewer failed entries (3% vs 15%) and significantly fewer puncture attempts (median 1.0 vs 3.5, p = 0.019), without increased gas-related complications. CONCLUSION: Replacing the saline column with a manometric display did not increase access-related complications and improved procedural efficiency. The NPMV4 technique further improved the reliability of laparoscopic access in obese patients. These stepwise modifications provide a simple, reproducible, and reliable approach to Veress needle access across diverse surgical populations.
引用
- Sato M, Torii K, Hiramatsu Y, et al. Stepwise evolution and clinical applicability of negative pressure-based manometric visualization for reliable Veress needle access. Surg Endosc. 2026. PMID: 41806039. doi:10.1007/s00464-026-12693-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。