结直肠手术围术期内脏灌注变化:ICG分光光度法与荧光血管造影的探索性研究
结果显示内脏灌注指标无显著个体内变化但个体间差异大,远端切除者术后反弹更明显,术中ICGR15降低与并发症发生相关(p=0.041),定量荧光参数与分光光度法PDR呈适度相关。
要点
- 结直肠手术中内脏灌注个体间差异大,远端切除时更明显。
- 术中ICGR15降低与并发症发生相关,但与严重并发症无关。
- 定量荧光参数与分光光度法PDR适度相关,或可辅助术中灌注监测。
核心结论
- 结直肠手术术中内脏灌注变异显著,尤其在远端结直肠切除时。
- 定性ICGFA可能不反映全身低灌注,但定量荧光分析与分光光度法结果一致,支持其作为补充性术中灌注监测工具的潜力。
研究设计与样本
- 术前、术中及术后第4天用ICG脉冲分光光度法(LiMON)测PDR和ICGR15。
- 术中同时由经验丰富外科医生目视判断ICGFA(Pinpoint),并对部分 recorded 手术行荧光强度-时间曲线定量分析。
主要发现
- 22例(79%)行结直肠节段切除一期吻合,其中19例(68%)吻合。
- LiMON灌注指标在各测量时间点无显著个体内变化,但个体间变异大,尤其术中,年龄>65岁和远端切除者更明显。
- 远端切除患者术后反弹倾向更大。
- 发生并发症的患者术中ICGR15相对降低(p=0.041),但与严重并发症无显著关联。
- 探索性回归分析发现分光光度法PDR值与荧光衍生参数(包括最大强度和达峰时间)呈适度关联。
临床怎么用
- 结直肠手术中可考虑用ICG脉冲分光光度法监测内脏灌注,注意个体间差异。
- 远端结直肠切除患者术中及术后灌注变化更明显,需加强监测。
- 定量ICGFA参数或可补充分光光度法评估术中灌注。
局限性
- 定量荧光分析仅在部分 recorded 手术的亚组中进行。
- 术中ICGR15与并发症的关联需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Indocyanine green (ICG) fluorescence enables validated clinical assessment of both global splanchnic perfusion, via specialised peripheral pulse spectrophotometry, and local intestinal perfusion, via near-infrared fluorescence angiography (ICGFA). This exploratory study investigated perioperative variations and correlations in measurements by these technologies, including their possible relevance with outcomes, in patients undergoing colorectal surgery. METHODS: In consenting patients, plasma disappearance rate (PDR) and percentage of residual ICG at 15 min (ICGR15) were measured preoperatively, intraoperatively and on postoperative day four using ICG-pulse spectrophotometry (LiMON, Getinge). ICGFA (Pinpoint, Stryker) was visually judged by an experienced surgeon concurrently with LiMON assessment intraoperatively and with quantitative analysis of fluorescence intensity-time curves in a subgroup of recorded procedures. RESULTS: Twenty-eight patients were included, of whom 22 (79%) underwent segmental colorectal resection with primary anastomosis in 19 (68%). While no significant within-subject variation in LiMON-derived perfusion indices evidenced across measurement time points, there was substantial inter-subject variation (notably with age > 65 years and distal resections), especially intraoperatively. Patients having distal resections tended towards greater postoperative rebound. Although patients who developed complications exhibited relatively reduced ICGR15 intraoperatively (p = 0.041), there was no significant association with severe complications. Exploratory regression analyses found a modest association between spectrophotometric PDR values and fluorescence-derived parameters, including maximum intensity and time to peak intensity. CONCLUSION: Intraoperative splanchnic perfusion varies substantially, particularly during distal colorectal resections. Although qualitative ICGFA may not reflect global hypoperfusion, quantitative fluorescence analysis shows concordance with spectrophotometric findings, supporting its potential as a complementary intraoperative perfusion-monitoring tool in colorectal surgery.
引用
- Meneghesso PE, Moynihan A, Singaravelu A, et al. Perioperative splanchnic perfusion variation around colorectal surgery using both indocyanine green spectrophotometry and fluorescence angiography. Surg Endosc. 2026. PMID: 41772218. doi:10.1007/s00464-026-12680-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。