文献速递胃肠外科围术期管理与 ERAS

结直肠手术围术期内脏灌注变化:ICG分光光度法与荧光血管造影的探索性研究

Perioperative splanchnic perfusion variation around colorectal surgery using both indocyanine green spectrophotometry and fluorescence angiography.
PubMed 文献 · Surg Endosc · 2026-03-02

结果显示内脏灌注指标无显著个体内变化但个体间差异大,远端切除者术后反弹更明显,术中ICGR15降低与并发症发生相关(p=0.041),定量荧光参数与分光光度法PDR呈适度相关。

要点

  • 结直肠手术中内脏灌注个体间差异大,远端切除时更明显。
  • 术中ICGR15降低与并发症发生相关,但与严重并发症无关。
  • 定量荧光参数与分光光度法PDR适度相关,或可辅助术中灌注监测。

核心结论

  • 结直肠手术术中内脏灌注变异显著,尤其在远端结直肠切除时。
  • 定性ICGFA可能不反映全身低灌注,但定量荧光分析与分光光度法结果一致,支持其作为补充性术中灌注监测工具的潜力。

研究设计与样本

  • 术前、术中及术后第4天用ICG脉冲分光光度法(LiMON)测PDR和ICGR15。
  • 术中同时由经验丰富外科医生目视判断ICGFA(Pinpoint),并对部分 recorded 手术行荧光强度-时间曲线定量分析。

主要发现

  • 22例(79%)行结直肠节段切除一期吻合,其中19例(68%)吻合。
  • LiMON灌注指标在各测量时间点无显著个体内变化,但个体间变异大,尤其术中,年龄>65岁和远端切除者更明显。
  • 远端切除患者术后反弹倾向更大。
  • 发生并发症的患者术中ICGR15相对降低(p=0.041),但与严重并发症无显著关联。
  • 探索性回归分析发现分光光度法PDR值与荧光衍生参数(包括最大强度和达峰时间)呈适度关联。

临床怎么用

  • 结直肠手术中可考虑用ICG脉冲分光光度法监测内脏灌注,注意个体间差异。
  • 远端结直肠切除患者术中及术后灌注变化更明显,需加强监测。
  • 定量ICGFA参数或可补充分光光度法评估术中灌注。

局限性

  • 定量荧光分析仅在部分 recorded 手术的亚组中进行。
  • 术中ICGR15与并发症的关联需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Indocyanine green (ICG) fluorescence enables validated clinical assessment of both global splanchnic perfusion, via specialised peripheral pulse spectrophotometry, and local intestinal perfusion, via near-infrared fluorescence angiography (ICGFA). This exploratory study investigated perioperative variations and correlations in measurements by these technologies, including their possible relevance with outcomes, in patients undergoing colorectal surgery. METHODS: In consenting patients, plasma disappearance rate (PDR) and percentage of residual ICG at 15 min (ICGR15) were measured preoperatively, intraoperatively and on postoperative day four using ICG-pulse spectrophotometry (LiMON, Getinge). ICGFA (Pinpoint, Stryker) was visually judged by an experienced surgeon concurrently with LiMON assessment intraoperatively and with quantitative analysis of fluorescence intensity-time curves in a subgroup of recorded procedures. RESULTS: Twenty-eight patients were included, of whom 22 (79%) underwent segmental colorectal resection with primary anastomosis in 19 (68%). While no significant within-subject variation in LiMON-derived perfusion indices evidenced across measurement time points, there was substantial inter-subject variation (notably with age > 65 years and distal resections), especially intraoperatively. Patients having distal resections tended towards greater postoperative rebound. Although patients who developed complications exhibited relatively reduced ICGR15 intraoperatively (p = 0.041), there was no significant association with severe complications. Exploratory regression analyses found a modest association between spectrophotometric PDR values and fluorescence-derived parameters, including maximum intensity and time to peak intensity. CONCLUSION: Intraoperative splanchnic perfusion varies substantially, particularly during distal colorectal resections. Although qualitative ICGFA may not reflect global hypoperfusion, quantitative fluorescence analysis shows concordance with spectrophotometric findings, supporting its potential as a complementary intraoperative perfusion-monitoring tool in colorectal surgery.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Meneghesso PE, Moynihan A, Singaravelu A, et al. Perioperative splanchnic perfusion variation around colorectal surgery using both indocyanine green spectrophotometry and fluorescence angiography. Surg Endosc. 2026. PMID: 41772218. doi:10.1007/s00464-026-12680-1