内镜下袖状胃成形术后胃几何形态改变的动态磁共振成像评估
本研究采用动态磁共振成像评估内镜下袖状胃成形术(ESG)对食管胃交界处几何形态的影响。
要点
- ESG术后6个月His角显著减小,可能对胃食管反流病具有保护作用。
- 术前有反流症状者中50%术后症状缓解并停用PPI,无新发反流。
- 动态磁共振成像可用于量化ESG术后胃几何形态变化。
核心结论
- ESG术后His角减小,可能作为防止胃食管反流病发展的保护因素。
主要发现
- 12例(54.5%)患者术前有胃食管反流症状并使用PPI,术后12个月内6例(50%)症状缓解并停用PPI,无新发胃食管反流病。
- 术前平均His角为62.2°(SD 10.3°),术后6个月平均为59.6°(SD 10.2°),差异有统计学意义(P=0.05)。
临床怎么用
- ESG可能在不增加反流风险的情况下实现减重,但需更大样本验证。
- 动态磁共振成像可用于评估ESG术后胃几何形态变化。
局限性
- 未来需开发自动分割算法并扩大样本量以减少测量变异性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Sleeve gastrectomy (SG) induces weight loss through tubulization of the stomach. Up to 35% of SG patients develop Gastroesophageal Reflux Disease (GERD). The pathophysiological mechanism for GERD development has been associated to changes in the geometry and mechanics of the Esophago-Gastric junction (EGJ). Endoscopic sleeve gastroplasty (ESG) is an endoscopic bariatric procedure leading to weight loss and obesity-related comorbidities resolution through gastric restriction and shortening. Unlike SG, ESG preserves the gastric fundus, potentially resulting in lesser impact on EGJ geometry. This study aimed to identify and quantify the geometric changes of the EGJ following ESG using dynamic magnetic resonance imaging (Dy-MRI). METHODS: ESG patients were enrolled to undergo Dy-MRI. Dy-MRI performed before and 6 months after ESG consisted in ingestion of a 400 mL liquid meal and images acquisition every 20 min, up to 120 min post-ingestion. 3D-segmentations of the stomach were generated through the 3D Slicer software. The His angle (HA) was calculated by identifying anatomical landmarks, on sagittal, coronal, and transverse planes for precise comparison between pre- and postoperative images. Clinical data were collected over a 12 months period. RESULTS: Of the 25 patients who underwent pre- and postoperative Dy-MRI, 3 were excluded due image abnormality. 12 (54.5%) patients reported preoperative GERD symptoms and PPI use. Over 12 months follow-up 6/12 patients (50%) reported resolution of GERD symptoms and stopped PPI use. No de-novo GERD was reported. Computation of gastric geometry modifications revealed a significant (p-value 0.05) difference between mean pre-procedure HA degree 62.2° (SD 10.3°), and mean post-procedure (6 months) degree 59.6° (SD 10.2°). CONCLUSIONS: ESG reduces the HA degree which may serve as a protective factor against GERD development. Future steps will include developing automatic segmentation algorithms and leveraging software such as VTK to minimize measurement variability and enhance reproducibility in a larger patients cohort.
引用
- Vannucci M, Heikens N, Berardo A, et al. Dynamic magnetic resonance imaging evaluation of stomach geometry modifications after endoscopic sleeve gastroplasty. Surg Endosc. 2026. PMID: 41731136. doi:10.1007/s00464-026-12645-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。