技术误差对微创远端胃切除腔内三角吻合短期及一年结局的影响
单中心回顾性研究纳入2008至2022年749例微创远端胃切除后行腔内三角吻合Billroth I式患者,由36名术者完成。术中吻合并发症发生0.8%,术后吻合相关并发症2.1%,吻合口漏、狭窄和胃排空延迟分别为0.9%、0.3%和0.9%。术后1年无迟发狭窄,有无并发症患者营养与内镜 findings 无显著差异。
要点
- 遵循五项基本要素的腔内三角吻合安全可重复
- 术中吻合并发症主要与直线切割吻合器技术问题有关
- 术后吻合相关并发症多数可保守或内镜处理
核心结论
- 遵循五项基本技术原则时,腔内三角吻合Billroth I式安全、可重复且一年结局良好。
研究设计与样本
- 单中心回顾性研究,纳入2008至2022年在本机构接受微创远端胃切除后行三角吻合Billroth I式的患者,共749例,涉及36名术者。
主要发现
- 术中吻合并发症发生率为0.8%,主要归因于直线切割吻合过程中的技术问题。
- 术后吻合相关并发症发生率为2.1%,其中吻合口漏0.9%、狭窄0.3%、胃排空延迟0.9%。
- 大多数并发症通过保守或内镜方式处理。
- 术后1年未观察到迟发性狭窄,有无并发症患者间的营养状态和内镜表现无显著差异。
临床怎么用
- 术中应严格遵循五项基本技术要素,特别注意直线切割吻合环节以减少技术误差。
- 术后吻合相关并发症多数可经保守或内镜处理,无需过早再次手术干预。
局限性
- 单中心回顾性研究,数据来自前瞻性维护数据库但分析为回顾性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intracorporeal delta-shaped Billroth I (B-I) anastomosis following minimally invasive distal gastrectomy (DG) is a simple and highly reproducible gastroduodenostomy procedure. This study aimed to identify the technical pitfalls of this procedure and assess their influence on one-year outcomes. METHODS: This was a retrospective study including patients who underwent delta-shaped B-I anastomosis following minimally invasive DG at our institution between 2008 and 2022. Delta-shaped B-I anastomosis was performed by adhering to five fundamental elements. Data were collected from our prospectively maintained database and analyzed retrospectively. Intra- and postoperative complications were reviewed, and video analysis was performed to identify technical errors associated with these complications. One-year outcomes, including nutritional status and endoscopic findings, were compared between patients with and without complications within 30 days after surgery. RESULTS: A total of 749 patients were included in this study. A total of 36 operating surgeons were involved. Intraoperative anastomotic complications occurred in 0.8% of patients, mainly due to technical issues during linear stapling. Postoperative anastomosis-related complications occurred in 2.1% of patients, with anastomotic leakage, stricture, and delayed gastric emptying rates of 0.9%, 0.3%, and 0.9%, respectively. Most complications were managed conservatively or endoscopically. No late-onset strictures were observed at postoperative year 1, and no significant differences in nutritional and endoscopic findings were observed between patients with and without complications. CONCLUSION: When performed according to five fundamental technical principles, intracorporeal delta-shaped B-I anastomosis following minimally invasive DG proved to be a safe, reproducible procedure associated with favorable one-year outcomes.
引用
- Matsuo K, Shibasaki S, Suzuki K, et al. Influence of technical errors on short-term and one-year outcomes after intracorporeal delta-shaped Billroth I anastomosis following minimally invasive distal gastrectomy: a single-center retrospective study. Surg Endosc. 2026. PMID: 41559342. doi:10.1007/s00464-025-12544-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。