机器人手术治疗复杂创伤性腹壁疝的单中心经验
该单中心回顾性研究分析了109例侧腹壁疝修补术,其中21例(19.3%)为钝性创伤所致,多数源于机动车碰撞并累及侧腹(L2)和腰部(L4)区域。所有病例均行机器人修补,38.1%行机器人腹横肌松解,9.5%中转开放腹横肌松解,平均疝宽度10.7 cm、补片面积455.5 cm²;中位随访1年无疝复发,仅3例无症状血清肿和1例需再入院的深部肌肉脓肿。结论认为机器人修补钝性创伤性侧腹壁疝可行且安全,并发症和复发率低。
要点
- 钝性创伤性侧腹壁疝多由机动车碰撞引起,常累及侧腹(L2)和腰部(L4)区域。
- 机器人修补全部完成,38.1%行机器人腹横肌松解,9.5%中转开放腹横肌松解。
- 中位随访1年无疝复发,并发症为3例无症状血清肿和1例深部肌肉脓肿。
核心结论
- 机器人修补钝性创伤性侧腹壁疝可行且安全,并发症和复发率低。
研究设计与样本
- 单中心回顾性研究,在高容量疝中心接受腹壁疝修补术的患者中识别继发于钝性创伤的侧腹壁疝患者,分析人口学、疝特征、手术技术和结局。
- 共109例侧腹壁疝修补,其中21例(19.3%)为创伤相关。
主要发现
- 创伤性侧腹壁疝多数由机动车碰撞引起(76.2%),常累及侧腹(L2)和腰部(L4)区域。
- 所有病例均行机器人修补,38.1%行机器人腹横肌松解,9.5%中转开放腹横肌松解。
- 平均疝宽度10.7 cm,平均补片面积455.5 cm²。
- 并发症包括3例无症状血清肿(14.3%)和1例需再入院的深部肌肉脓肿。
- 中位随访1年期间未观察到疝复发。
临床怎么用
- 对钝性创伤性侧腹壁疝可采用机器人修补,必要时联合机器人腹横肌松解,并准备中转开放。
- 此类损伤常合并中线缺损,可能需要高级重建技术,应重视手术经验和优化准备。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Blunt traumatic lateral abdominal-wall hernias are complex injuries often resulting from high-energy mechanisms. These injuries commonly involve disruption of the transversus abdominis muscle, obliques, as well as potential injury avulsion of the diaphragm in thoracoabdominal hernias. Because of the variety of injury patterns, blunt traumatic lateral abdominal-wall hernias present unique reconstructive challenges, particularly when involving the iliac crest or costal margin. Despite increasing use of robotic-assisted techniques for abdominal wall reconstruction, limited data exist on their use in traumatic hernias. METHODS: We conducted a retrospective review of patients undergoing ventral hernia repair at our high-volume hernia center. Patients with lateral hernias secondary to blunt trauma were identified. Demographics, hernia characteristics, operative techniques, and outcomes were analyzed. Subgroup analysis was performed for patients undergoing robotic transversus abdominis release. RESULTS: Of 109 lateral hernia repairs, 21 (19.3%) were trauma-related. Most were due to motor vehicle collisions (76.2%) and commonly involved flank (L2) and lumbar (L4) regions. Robotic repair was performed in all cases, including robotic transversus abdominis release in 38.1% and conversion to open transversus abdominis release in 9.5%. Mean hernia width was 10.7 cm, with a mean mesh area of 455.5 cm2. Complications included 3 asymptomatic seromas (14.3%) and 1 deep muscle abscess requiring readmission. No hernia recurrences were observed during a median follow-up of 1 year. CONCLUSION: Robotic repair of blunt traumatic lateral abdominal-wall hernias is feasible and safe, with low complication and recurrence rates. These injuries frequently coexist with midline defects and may require advanced techniques, underscoring the importance of surgical expertise and optimization.
引用
- Balthazar da Silveira C, Horiuchi S, Rasador AD, et al. Robotic management of complex traumatic hernias: A single-center experience. Surgery. 2025. PMID: 41330253. doi:10.1016/j.surg.2025.109938
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。