机器人双侧腋乳入路甲状腺切除术的学习曲线与功能安全性:537例前瞻性研究
该前瞻性队列研究纳入537例分化型甲状腺癌患者,分析机器人双侧腋乳入路甲状腺切除联合中央颈清扫的学习曲线。累积和分析显示手术时间在152例和352例后进入平台期,术中喉返神经不良事件从16.7%降至1.6%,误切甲状旁腺从23.8%降至1.6%,6个月PTH水平改善。
要点
- 手术时间从189.9分钟降至129.3分钟,平台期在152例和352例。
- 术中喉返神经不良事件从16.7%降至1.6%,误切甲状旁腺从23.8%降至1.6%。
- 6个月PTH水平从3.15升至4.14 pmol/L,淋巴结检出数从9.9增至13.3(P=0.019)。
核心结论
- 机器人BABA甲状腺切除术具有结构化的学习曲线,功能安全性随经验和术中标准化而改善。
研究设计与样本
- 前瞻性队列研究,2018年3月至2024年3月在高容量内分泌外科中心纳入537例连续分化型甲状腺癌患者,均行机器人BABA甲状腺切除联合中央颈清扫。
主要发现
- 手术时间从189.9分钟降至129.3分钟(P<0.001),平台期在152例和352例。
- 术中喉返神经不良事件从16.7%(95%CI 7.9-30.2%)降至1.6%(95%CI 0.3-4.8%)。
- 误切甲状旁腺从23.8%(95%CI 12.0-39.5%)降至1.6%(95%CI 0.3-4.8%)。
- 6个月PTH水平从3.15升至4.14 pmol/L,淋巴结检出数从9.9增至13.3(P=0.019)。
- 3例(0.6%)发生气管瘘。
关键数值与推荐
- 术中采用实时喉返神经监测、术中PTH检测和纳米碳淋巴结示踪。
- 学习阶段通过累积和分析定义。
临床怎么用
- 数据驱动的里程碑可用于机器人甲状腺手术的结构化培训和资质认证框架。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: Robotic thyroidectomy via the bilateral axillo-breast approach (BABA) provides excellent cosmetic outcomes, but its adoption is limited by a steep learning curve and concerns about functional safety. This study aimed to define the learning curve trajectory and evaluate functional safety outcomes-with the primary endpoint of intraoperative RLN adverse events and secondary endpoints of inadvertent parathyroidectomy and PTH recovery. METHODS: A prospective cohort study was conducted at a high-volume endocrine surgery center from March 2018 to March 2024. A total of 537 consecutive patients with differentiated thyroid carcinoma underwent robotic BABA thyroidectomy with central neck dissection. Intraoperative refinements included real-time recurrent laryngeal nerve (RLN) monitoring, intraoperative parathyroid-hormone (PTH) testing, and nanocarbon lymph node mapping. Learning phases were defined by cumulative sum analysis. Primary outcomes were intraoperative RLN adverse events and inadvertent parathyroidectomy; secondary outcomes included operative time, lymph node yield, PTH recovery, complication rates, and tracheal injury. RESULTS: Among 537 patients (401 women, 74.7%; median age 43 years), operative time decreased from 189.9 to 129.3 min (P < 0.001), with plateaus at 152 and 352 cases. RLN adverse events declined from 16.7% (95% CI 7.9-30.2%) to 1.6% (95% CI 0.3-4.8%), and inadvertent parathyroidectomy decreased from 23.8% (95% CI 12.0-39.5%) to 1.6% (95% CI 0.3-4.8%). Six-month PTH levels improved from 3.15 to 4.14 pmol/L, and lymph node yield increased from 9.9 to 13.3 (P = 0.019). Three patients (0.6%) developed tracheal fistula. CONCLUSIONS: Robotic BABA thyroidectomy demonstrates a structured learning curve in which functional safety improves with surgical experience and intraoperative standardization. These data-driven milestones may inform structured training and credentialing frameworks for robotic thyroid surgery.
引用
- Wang SS, Tang ZH, Huang WY, et al. Learning curve and functional safety in robotic thyroidectomy via bilateral axillo-breast approach: a prospective study of 537 cases. Surg Endosc. 2025. PMID: 41152529. doi:10.1007/s00464-025-12331-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。