文献速递肝胆胰外科

吲哚菁绿荧光导航对比常规腹腔镜肝切除术治疗肝血管瘤:倾向性评分匹配研究

Indocyanine green fluorescence navigation versus conventional laparoscopic hepatectomy for hepatic hemangioma: a propensity score matched study.
PubMed 文献 · Surg Endosc · 2025-10-09

该回顾性队列研究纳入四川大学华西医院2015年5月至2024年4月接受腹腔镜肝切除术的肝血管瘤患者,经1:3倾向性评分匹配比较ICG荧光导航腹腔镜肝切除术(ICG-LH)与常规腹腔镜肝切除术(LH)的围术期指标。结果显示ICG-LH组术中失血量更少(中位数100 ml vs 200 ml,p<0.001)、住院时间更短(5.9天 vs 7.1天,p<0.001),术后第1天和第3天白蛋白水平显著更高(p<0.05);在IWATE评分>9的亚组中,ICG-LH组手术时间更短(158.3 min vs 224.4 min,p<0.001)、失血量更少(100 ml vs 500 ml,p=0.001)、肝血流阻断次数更少(1.5次 vs 3次,p=0.002)、总阻断时间更短(35 min vs 55 min,p=0.004)。结论认为ICG-LH在肝血管瘤切除术中围术期表现优于常规LH。

要点

  • ICG-LH组术中失血量中位数100 ml,低于LH组的200 ml(p<0.001)。
  • ICG-LH组住院时间中位数5.9天,短于LH组的7.1天(p<0.001)。
  • IWATE评分>9的亚组中,ICG-LH手术时间、失血量、肝血流阻断次数及总阻断时间均优于LH。

核心结论

  • ICG-LH在肝血管瘤切除术中围术期表现优于常规LH,可能优化术后功能恢复并减少手术相关并发症。

研究设计与样本

  • 回顾性队列研究,纳入四川大学华西医院2015年5月至2024年4月接受腹腔镜肝切除术的肝血管瘤患者。
  • 采用1:3倾向性评分匹配(PSM)比较ICG-LH组与LH组围术期变量。

主要发现

  • ICG-LH组术中失血量中位数100 ml,LH组200 ml(p<0.001)。
  • ICG-LH组住院时间中位数5.9天,LH组7.1天(p<0.001)。
  • ICG-LH组术后第1天和第3天白蛋白水平显著高于LH组(p<0.05)。
  • IWATE评分>9亚组中,ICG-LH组手术时间158.3 min vs LH组224.4 min(p<0.001)。
  • IWATE评分>9亚组中,ICG-LH组失血量100 ml vs LH组500 ml(p=0.001),肝血流阻断次数1.5次 vs 3次(p=0.002),总阻断时间35 min vs 55 min(p=0.004)。

临床怎么用

  • 对于肝血管瘤行腹腔镜肝切除术,尤其是IWATE评分>9的复杂病例,可考虑使用ICG荧光导航以改善围术期指标。

局限性

  • 本研究为回顾性分析,可能存在选择偏倚,结论需前瞻性研究进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Indocyanine Green (ICG) fluorescence navigation is increasingly used in laparoscopic liver surgeries, yet its benefits for hepatic hemangioma resection remain unclear. This study assessed the effectiveness and clinical value of ICG fluorescence navigation laparoscopic hepatectomy for hepatic hemangioma, compared with the conventional laparoscopic resection. METHODS: We retrospectively analyzed a cohort of hepatic hemangioma patients who underwent laparoscopic hepatectomy at West China Hospital of Sichuan University from May 2015 to April 2024. Propensity score matching (PSM) was utilized to match patients undergoing ICG fluorescence navigation laparoscopic hepatectomy (ICG-LH) with those undergoing conventional laparoscopic hepatectomy (LH) in a 1:3 ratio to minimize the influence of confounding factors. We compared perioperative variables between the two groups to ascertain the superior method for hepatic hemangioma hepatectomy. RESULTS: ICG-LH demonstrated superior perioperative outcomes (median blood loss: 100 ml vs 200 ml, p < 0.001; hospitalization: 5.9 days vs 7.1 days, p < 0.001). Albumin levels on postoperative day 1 and day 3 were found to be significantly higher in the ICG-LH compared to the LH group (p < 0.05). Subgroup analyses based on IWATE criteria revealed that, in patients with an IWATE score greater than 9, compared to the LH group patients, ICG-LH patients exhibited shorter operative time (158.3 min vs 224.4 min, p < 0.001), significantly reduced blood loss (100 ml vs 500 ml, p = 0.001), decreased number of hepatic inflow occlusions (1.5 times vs 3 times, p = 0.002), and a reduction in the total duration of hepatic inflow occlusion (35 min vs 55 min, p = 0.004). CONCLUSIONS: The comparative analysis revealed the advantages of ICG-LH over conventional LH approaches for hepatic hemangioma resection, demonstrating its enhanced perioperative performance metrics, and may potentially optimize postoperative functional recovery while reducing procedure-related morbidity.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Yu ZN, Li L, Wang L, et al. Indocyanine green fluorescence navigation versus conventional laparoscopic hepatectomy for hepatic hemangioma: a propensity score matched study. Surg Endosc. 2025. PMID: 41068415. doi:10.1007/s00464-025-12270-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。