新型2毫米针式腔内组装镊在乳晕旁胸腔镜手术中的初步应用经验
因对照组均为单孔病例,组间比较预设于单孔子集(2毫米45例 vs 5毫米37例)。结果显示2毫米组在瘢痕评估和早期疼痛评分上显著优于5毫米组,手术时间和术者难度相当,无严重并发症或围术期死亡。
要点
- 2毫米针式镊在乳晕旁胸腔镜手术中安全可行,无严重并发症或围术期死亡。
- 单孔亚组中2毫米组术后6个月POSAS总分和术后1周VAS疼痛评分显著低于5毫米组。
- 器械组装和拆卸分别需100±28秒和25±11秒,针式穿刺点无需缝合且瘢痕极小。
核心结论
- 新型2毫米腔内镊用于乳晕旁胸腔镜手术安全有效,可显著改善美容效果和手术效率。
研究设计与样本
- 2毫米组78例(单孔45例,双孔33例),历史5毫米对照组37例(均为单孔)。
- 组间比较预设于单孔子集(2毫米45例 vs 5毫米37例),双孔病例仅作描述性总结。
主要发现
- 共完成115例乳晕旁胸腔镜手术,无严重并发症或围术期死亡。
- 器械组装耗时100±28秒,拆卸耗时25±11秒。
- 针式穿刺点无需缝合,随访时瘢痕轻微至极少。
- 单孔亚组中2毫米组POSAS总分和早期VAS疼痛评分显著低于5毫米组,手术时间和术者报告难度相当。
- 共发生3例轻微乳腺腺体损伤(2毫米组2例,5毫米组1例),无持久感觉障碍。
临床怎么用
- 乳晕旁胸腔镜手术可考虑使用2毫米针式腔内组装镊以减少切口相关创伤和改善美容效果。
- 使用该器械需注意组装和拆卸耗时,并关注穿刺点相关乳腺腺体损伤风险。
局限性
- 本研究为单中心回顾性观察性研究。
- 对照组为历史5毫米抓钳病例且仅含单孔病例,双孔2毫米病例仅作描述性总结。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Periareolar video-assisted thoracoscopic surgery (VATS) provides cosmetic advantages but poses technical challenges due to limited working space. The novel 2-mm needle-type intracorporeal assembly endoscopic forceps is designed to minimize incision size while retaining full surgical functionality. This study aimed to evaluate the feasibility, safety, and effectiveness of this novel endoscopic forceps in periareolar VATS. METHODS: This single-center retrospective observational study included patients who underwent periareolar VATS using either the 2-mm forceps or a conventional 5-mm grasper between January and December 2024. Outcomes included operative time, complications, visual analog scale (VAS) pain scores at 1 week and 1 month, patient and observer scar assessment scale (POSAS) scores at 6 months, and surgeon feedback. Patients were stratified as follows: 2-mm group (n = 78; uniportal 45, biportal 33) and a historical 5-mm control (n = 37; all uniportal) from the same team under identical indications and perioperative protocols. Because the control contained only uniportal cases, all between-group comparisons were prespecified for the uniportal subset (2 mm: 45 vs. 5 mm: 37); 2-mm biportal cases were summarized descriptively. RESULTS: A total of 115 periareolar VATS procedures were completed without severe complications or perioperative mortality. Instrument assembly and disassembly required 100 ± 28 s and 25 ± 11 s, respectively. The needle-type puncture sites required no suturing and showed minimal-to-virtually no scarring at follow-up. In the uniportal subset, the 2-mm group had significantly lower POSAS totals and early VAS scores than the 5-mm group, with comparable operative time and surgeon-reported difficulty. Three minor mammary gland injuries occurred overall (two in the 2-mm group and one in the 5-mm group), with no lasting sensory impairment. CONCLUSIONS: The novel 2-mm intracorporeal forceps is safe and effective for periareolar VATS, significantly enhancing cosmetic outcomes and surgical efficiency, suggesting broad clinical application potential.
引用
- Wang W, Zhang S, Dong P, et al. Initial experience with a novel 2-mm needle-type intracorporeal assembly forceps for periareolar video-assisted thoracoscopic surgery. Surg Endosc. 2025. PMID: 40935942. doi:10.1007/s00464-025-12177-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。