躯体功能测试与腹壁疝大小是否存在关联
本研究基于ABVENTURE-P随机对照试验前瞻性收集的队列数据,纳入2022年4月至2024年8月期间112例计划行腹壁疝修补术的患者,术前完成五次坐立试验(5×STS)和计时起立行走测试(TUG),并在术中测量疝宽度。结果显示,无论将疝宽度作为连续变量还是按欧洲疝学会(EHS)分型分析,躯体功能测试评分与腹壁疝大小均无显著关联。
要点
- 5×STS与疝宽度连续变量无显著相关(Spearman rho=0.13,p=0.19)。
- TUG与疝宽度连续变量无显著相关(Spearman rho=0.13,p=0.16)。
- 按EHS分型分析,5×STS(p=0.12)与TUG(p=0.08)均无显著差异。
核心结论
- 在本队列中,躯体功能测试评分单独与腹壁疝大小不相关。
- 疝宽度作为连续变量或按EHS分型分析时,均与5×STS或TUG表现无显著关联。
研究设计与样本
- 研究为队列研究,数据来自随机对照试验ABVENTURE-P的前瞻性收集资料。
- 纳入2022年4月至2024年8月期间计划行腹壁疝修补术的患者,共112例。
- 术前完成5×STS与TUG测试,疝宽度于修补术中测量。
- 采用Spearman秩相关检验分析疝宽度与功能测试的关联,采用单因素方差分析分析EHS分型与功能测试的关联。
主要发现
- 平均疝宽度为7 cm(SD 7 cm)。
- EHS分型分布为47% W1、29% W2、24% W3。
- 5×STS与疝宽度连续变量分析:Spearman rho=0.13,p=0.19;按EHS分型分析:p=0.12。
- TUG与疝宽度连续变量分析:Spearman rho=0.13,p=0.16;按EHS分型分析:p=0.08。
临床怎么用
- 提示临床不应仅凭躯体功能测试评分推断腹壁疝大小或进行术前风险评估。
- 疝宽度与功能测试无显著关联,术前功能评估与疝形态学评估应分别解读。
局限性
- 本研究为基于随机对照试验的前瞻性队列数据,样本量112例,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Clinical assessments of physical function are widely used to evaluate candidacy and predict outcomes for various procedures. This study investigates the relationship between ventral hernia size and physical function tests. METHODS: A cohort study was performed on prospectively collected data as part of a randomized control trial Pilot Trial of Abdominal Core Rehabilitation To Improve Outcomes After Ventral Hernia Repair (ABVENTURE-P). Patients scheduled for ventral hernia repair were enrolled between 4/2022 and 8/2024. Patients completed the Five Times Sit-to-Stand (5 × STS) and Timed Up & Go (TUG) physical functional tests pre-operatively. Hernia width was then measured at the time of hernia repair. Associations between hernia width and physical function tests were assessed using Spearman's rank correlation tests, and associations between European Hernia Society (EHS) classifications and physical function tests were assessed using one-way ANOVA. RESULTS: A total of 112 patients were evaluated with a mean hernia width of 7 cm (SD 7 cm), classified by EHS as 47% W1, 29% W2, and 24% W3. No significant association was found between 5 × STS scores and hernia size when analyzed as a continuous variable (Spearman's rho = 0.13, p = 0.19) or across EHS classifications (p = 0.12). Similarly, TUG scores showed no significant correlation with hernia size as a continuous variable (Spearman's rho = 0.13, p = 0.16) or across EHS classifications (p = 0.08). CONCLUSION: Physical function test scores alone did not correlate with ventral hernia size in this cohort. Hernia width was not significantly associated with 5 × STS or TUG performance when analyzed as a continuous variable by EHS classification.
引用
- Head W, Satija D, Shannon K, et al. Is there a link between physical function testing and ventral hernia size? Surg Endosc. 2025. PMID: 41023219. doi:10.1007/s00464-025-12224-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。