基于机器学习的腹腔镜膈疝修补术中电外科器械所致出血检测
血液像素检测准确率94%、Dice评分0.472;出血分类准确率78.2%、精确率4.6%、特异性78.1%、敏感性81.0%。该方法能准确识别无出血的器械激活片段,但精确识别出血仍具挑战。
要点
- 随机森林检测血液像素准确率94%,Dice评分0.472。
- 逻辑回归分类器械所致出血准确率78.2%、精确率4.6%、敏感性81.0%。
- 方法可准确识别无出血片段,但出血精确识别仍待提升。
核心结论
- 机器学习方法可较准确识别无出血的器械激活视频片段,但精确识别出血仍困难。
研究设计与样本
- 随机森林采用80/20划分训练与测试,逻辑回归采用分层三折交叉验证评估性能。
主要发现
- 血液像素检测准确率94%,Dice评分0.472。
- 自动提取视频片段的出血分类准确率78.2%、精确率4.6%、特异性78.1%、敏感性81.0%。
临床怎么用
- 可用于术中监测电外科器械使用所致出血,为手术技能评估提供信息。
局限性
- 出血识别精确率低,需在更大、更多样化数据集上进一步开发。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Electrosurgical devices provide significant advantages for tissue dissection in laparoscopic procedures. However, achieving optimal hemostasis while minimizing tissue coagulation is challenging. Monitoring device-induced bleeding will provide viable information for surgical skills assessment. We aimed to automatically detect bleeding induced by electrosurgical device use in laparoscopic videos using machine learning. METHODS: We present a two-step methodology for the automated detection of device-induced bleeding. First, based on the color representation, a random forest classifier (RFC) detects blood pixels in the frames before and after the electrosurgical device activation. Subsequently, a logistic regression (LR) model decides whether bleeding has occurred based on the change in blood pixels. The moments of device activations during surgery can be extracted automatically by a synchronized recording of the laparoscopic video and energy generator data. The RFC and LR were developed on the manual annotation of 34 images and 2678 video fragments from forty-five patients who underwent diaphragmatic hernia repair between May 2023 and October 2024. The performance of the RFC was evaluated by an 80/20 split for training and testing, while a stratified threefold cross-validation assessed the LR performance. RESULTS: The blood pixel detection showed an accuracy of 94% and a Dice score of 0.472. The classification of automatically extracted video fragments showed that device-induced bleeding can be detected with a 78.2% accuracy, 4.6% precision, 78.1% specificity, and 81.0% sensitivity. CONCLUSION: The presented work on device-induced bleeding detection is a step toward quantifying the effect of electrosurgery use. We showed a machine learning-based methodology that accurately identifies video fragments of device activations without bleeding but struggles to identify bleeding precisely. Future work should focus on developing device-induced bleeding detection in a larger, more diverse dataset.
引用
- Ribbens VJ, Baltus SC, Tan CO, et al. Machine learning-based detection of electrosurgical device-induced bleeding in laparoscopic videos of diaphragmatic hernia repair. Surg Endosc. 2025. PMID: 40825896. doi:10.1007/s00464-025-12078-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。