文献速递甲状腺与颈部外科围术期管理与 ERAS

经皮连续迷走神经刺激在经口腔甲状腺切除术中优于经口电极

Percutaneous continuous vagal stimulation provided superior neuromonitoring over the peroral electrode in transoral thyroidectomy.
PubMed 文献 · Surg Endosc · 2025-08-06

该前瞻性研究纳入102例接受TOETVA的患者,比较经皮连续迷走神经刺激(PC组,52例67条风险神经)与常规经口DELTA电极(DELTA组,50例61条风险神经)的可行性与安全性。PC组电极置入时间更短、刺激器移位更少、肌电反应更稳定,且无术后声带麻痹,DELTA组发生2例声带麻痹。

要点

  • 经皮连续迷走神经刺激在TOETVA中技术可行,全部PC组患者成功建立监测。
  • PC组电极置入时间更短、刺激器移位更少、肌电反应更稳定。
  • PC组无术后声带麻痹,DELTA组发生2例声带麻痹。

核心结论

  • 经皮连续迷走神经刺激在TOETVA中优于经口迷走神经刺激,能更早感知喉返神经即将发生的损伤并及时补救。

研究设计与样本

  • 前瞻性研究纳入102例连续接受TOETVA的患者,PC组52例(67条风险神经),DELTA组50例(61条风险神经)。

主要发现

  • PC组全部成功建立连续术中神经监测,DELTA组有3例失败。
  • PC组电极置入时间更短、刺激器移位事件更少、肌电反应更稳定。
  • 4条风险神经出现喉返神经牵拉相关不良事件(PC组3条,DELTA组1条),均术中调整手术后恢复,无术后声带麻痹。
  • 严重减弱或消失的肌电信号见于4条风险神经(均属DELTA组),其中3条因迷走神经牵张损伤、1条因喉返神经牵拉损伤,导致2条风险神经术后声带麻痹。

临床怎么用

  • 在TOETVA中可考虑采用经皮连续迷走神经刺激技术,以更稳定地监测喉返神经功能并及时发现即将发生的损伤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Continuous intraoperative neuromonitoring (C-IONM) has been developed and used in open thyroidectomy to perceive imminent recurrent laryngeal nerve (RLN) injury, but has scarcely been reported in transoral endoscopic thyroidectomy vestibular approach (TOETVA) due to technical difficulty. This study aims to report the percutaneous C-IONM technology in TOETVA and compare it with the conventional peroral method to confirm its feasibility, safety, and effectiveness. METHODS: This prospective study included 102 consecutive patients who received TOETVA and standardized continuous vagal nerve (VN) stimulation via percutaneous insertion of commercially available handheld stimulation probe into the moderately dissected carotid space between carotid artery and internal jugular vein and fixed by an external fixator (PC group, n = 52 with 67 nerves at risk [NAR]) or conventional peroral DELTA electrode (DELTA group, n = 50 with 61 NAR). Demographic data, technical outcome variables, and electromyography (EMG) signals were collected and compared. RESULTS: C-IONM procedures were successfully set up in all PC group patients but failed in three DELTA group patients. Comparisons of technical characteristics show the PC group demonstrated a shorter electrode positioning time, fewer stimulator displacement events, and more stable EMG responses than the DELTA group. Four NARs (3 in PC, 1 in DELTA group) reported imminent recurrent laryngeal nerve (RLN) traction-related adverse events, all with intraoperative recovery after surgical technique modification, causing no postoperative vocal cord palsy. Severely weakened or loss of EMG signal occurred in 4 NARs (all in DELTA group), either due to stretch injury of VN (3 NAR) or traction injury of RLN (1 NAR), causing two postoperative VCP in 2 NARs. CONCLUSION: Percutaneous continuous vagal stimulation was superior to peroral vagal stimulation in a selected cohort of patients undergoing TOETVA to perceive the imminent injury of RLN to start immediate rescue.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Uen YH, Wu CW, Wen KS, et al. Percutaneous continuous vagal stimulation provided superior neuromonitoring over the peroral electrode in transoral thyroidectomy. Surg Endosc. 2025. PMID: 40767916. doi:10.1007/s00464-025-12009-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。