文献速递肝胆胰外科围术期管理与 ERAS

磁共振衍生肝脏摄取指数改善严重肝切除术后肝衰竭风险识别

Magnetic resonance-derived hepatic uptake index improves the identification of patients at risk of severe post-hepatectomy liver failure.
PubMed 文献 · Br J Surg · 2025-01-01

该多中心回顾性观察研究纳入292例2010至2020年间在瑞典、丹麦和芬兰接受大范围肝切除术的患者,评估术前Gd-EOB MRI获得的肝脏摄取指数(HUI)对严重肝切除术后肝衰竭(PHLF)的识别效能。结果显示25例(8.6%)发生严重PHLF,HUI的AUC为0.758,优于仅基于体积的sFLR(AUC 0.628),HUI联合MELD 3评分后AUC提升至0.803。

要点

  • HUI对严重PHLF的判别效能优于仅基于体积的sFLR。
  • HUI联合MELD 3评分可进一步优化严重PHLF的术前风险分层。
  • 常规术前Gd-EOB MRI获取的HUI可用于识别严重PHLF高危患者。

核心结论

  • 常规Gd-EOB MRI获得的HUI在识别严重PHLF风险方面优于基于体积的生物标志物sFLR。
  • 将影像衍生的功能评估HUI与独立生物标志物MELD 3评分结合,可能优化严重PHLF的术前风险分层并改善大范围肝切除术后结局。

研究设计与样本

  • 观察性回顾性多中心研究,纳入292例2010至2020年间在瑞典、丹麦和芬兰接受大范围肝切除术的患者。
  • 每例患者术前均行Gd-EOB MRI,评估HUI、标准化未来肝残肝摄取指数(sFLR-HUI)和MELD 3评分。
  • 统计分析包括逻辑回归和受试者工作特征(ROC)曲线评估,以确定严重PHLF(国际肝脏外科研究组B级和C级)的截断值和判别准确度。

主要发现

  • 292例患者中25例(8.6%)发生严重PHLF。
  • 发生严重PHLF的患者HUI和sFLR-HUI值显著更低(P < 0.001)。
  • HUI对严重PHLF的判别效能(AUC 0.758)优于仅基于体积的评估如sFLR(AUC 0.628)。
  • HUI联合MELD 3评分后判别效能进一步提升(AUC 0.803)。

临床怎么用

  • 可利用常规术前Gd-EOB MRI获取的HUI辅助识别严重PHLF高危患者。
  • 可将HUI与MELD 3评分联合用于大范围肝切除术前的风险分层。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Post-hepatectomy liver failure (PHLF) is a leading cause of mortality after major liver resection. Accurate preoperative risk assessment is essential, yet current methods have limitations. Gadoxetic acid-enhanced MRI (Gd-EOB MRI) enables both morphological and functional evaluation of the liver. The aim of this study was to evaluate the efficacy of the hepatic uptake index (HUI) obtained from routine preoperative Gd-EOB MRI for identifying patients at risk of severe PHLF. METHODS: This observational retrospective multicentre study included 292 patients who underwent major hepatectomy between 2010 and 2020 in Sweden, Denmark, and Finland. Preoperative Gd-EOB MRI was performed for each patient and the HUI, hepatic uptake index of the standardized future liver remnant (sFLR-HUI), and Model for End-Stage Liver Disease Version 3 (MELD 3) score were evaluated. Statistical analyses included logistic regression and receiver operating characteristic (ROC) curve assessment to determine cut-off values and discriminative accuracies for severe PHLF (International Study Group of Liver Surgery grades B and C). RESULTS: Among the 292 patients, 25 (8.6%) developed severe PHLF. Patients with severe PHLF had significantly lower HUI and sFLR-HUI values (P < 0.001). The HUI demonstrated superior discriminative performance for severe PHLF (area under the curve (AUC) 0.758) compared with volume-only assessments, such as the standardized future liver remnant (sFLR) (AUC 0.628). Combining the HUI with the MELD 3 score improved performance further (AUC 0.803). CONCLUSION: The HUI obtained from routine Gd-EOB MRI outperforms volume-based biomarkers (sFLR) for identification of patients at risk of severe PHLF. Incorporating image-derived functional assessments, such as the HUI, with independent biomarkers, such as the MELD 3 score, may optimize preoperative risk stratification for severe PHLF and improve outcomes after major hepatectomy. After major liver surgery, a small number of patients may experience a serious complication called post-hepatectomy liver failure (PHLF). This condition can be life-threatening. To reduce the risk, doctors try to assess how well the remaining part of the liver (called the future liver remnant) will function after surgery. Currently, doctors mainly use measurements of liver size (volume) to estimate this. However, these methods are not always reliable, especially in patients with other health issues or liver disease. This study looked at whether a new method based on a common type of liver scan (called Gd-EOB MRI) could better identify patients at risk of developing severe liver failure after surgery. This method uses a calculation called the hepatic uptake index (HUI), which considers both liver size and how well it works. Researchers studied 292 patients in Sweden, Denmark, and Finland who had major liver surgery between 2010 and 2020. All had a special MRI scan before their operation. The team measured how much of the contrast agent (Gd-EOB) was taken up by the liver. They compared this uptake (HUI) to traditional measurements of liver size and blood test results. They also looked at whether combining HUI with a blood-based score (called the MELD 3 score) improved results. Twenty-five out of 292 patients (8.6%) developed severe liver failure after surgery. These patients had lower HUI scores, showing their liver was less active on scans before surgery. The HUI worked better than liver volume alone to identify patients at risk. Adding the MELD 3 score further improved accuracy. A high HUI score meant very low risk of liver failure. The method worked well across different hospitals, even though they used different scanners and imaging settings. Using this MRI-based method could help doctors more accurately assess who is at risk of liver failure after surgery. This may improve decision-making, reduce complications, and make surgery safer. The study also suggests that combining liver imaging with blood test results gives the best overall picture.

来源:Br J Surg,查看原文。版权归原作者所有。

引用

  1. Bartholomä WC, Gilg S, Lundberg P, et al. Magnetic resonance-derived hepatic uptake index improves the identification of patients at risk of severe post-hepatectomy liver failure. Br J Surg. 2025. PMID: 40439010. doi:10.1093/bjs/znaf103

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。