线性吻合器关闭重叠吻合入孔在微创胃切除术中的疗效
本研究回顾性纳入172例微创胃切除术中行重叠吻合的患者,比较线性吻合器(LS)与手工缝合关闭入孔的手术结局。结果显示LS组在全胃切除和远端胃切除中均显著缩短吻合时间,远端胃切除组手术时间和术后住院时间亦缩短,且未增加吻合口狭窄风险。
要点
- LS关闭入孔可显著缩短全胃切除食管空肠重叠吻合时间(38.3 vs 20.5 min,P<0.001)。
- 远端胃切除中LS组手术时间(294 vs 253 min,P=0.002)和吻合时间(28.5 vs 9.0 min,P<0.001)更短。
- LS组未观察到吻合口狭窄,术后并发症发生率与手工缝合组相似。
核心结论
- 线性吻合器关闭重叠吻合入孔可缩短吻合时间,可能是安全选项且不增加狭窄风险。
研究设计与样本
- 回顾性研究纳入2020年2月至2024年9月期间172例腹腔镜或机器人辅助全胃切除(Roux-en-Y)或远端胃切除(Roux-en-Y/Billroth II)行重叠吻合的患者,分为手工缝合组(S组)和线性吻合器组(LS组)。
主要发现
- 全胃切除患者中LS组食管空肠重叠吻合时间显著短于S组(38.3 vs 20.5 min,P<0.001),手术时间无显著差异。
- 远端胃切除患者中LS组手术时间(294 vs 253 min,P=0.002)和胃空肠重叠吻合时间(28.5 vs 9.0 min,P<0.001)显著缩短。
- 远端胃切除患者LS组术后住院时间显著缩短(13 vs 11天,P=0.01)。
- 两组术后并发症发生率相似,LS组未观察到吻合口狭窄病例。
临床怎么用
- 在微创胃切除术的重叠吻合中,可考虑使用线性吻合器关闭入孔以缩短吻合时间,尤其适用于远端胃切除。
局限性
- 本研究为回顾性分析,样本量有限,结论需前瞻性研究进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Overlap anastomosis is widely used in gastrointestinal reconstruction during minimally invasive gastrectomy. The entry hole of the anastomosis is typically closed with hand-sewn sutures because of concerns about stenosis. This study aimed to compare the efficacy of linear stapler (LS) closure with that of hand-sewn closure of the entry hole in overlap anastomosis. METHODS: We included 172 patients who underwent overlap anastomosis during laparoscopic or robot-assisted total gastrectomy (TG, Roux-en-Y) or distal gastrectomy (DG, Roux-en-Y/Billroth II) between February 2020 and September 2024. The patients were divided into two groups based on the method of entry hole closure: the suturing group (S group) and the LS group. Surgical outcomes were retrospectively analyzed. RESULTS: There were no significant differences in patient characteristics or tumor staging between the two groups. TG was performed in 46 and 17 patients in the S and LS groups, respectively, whereas DG was performed in 41 and 68 patients in the S and LS groups, respectively. In TG patients, there was no significant difference in operative time, but the esophageal-jejunal overlap anastomosis time was significantly shorter in the LS group (38.3 vs. 20.5 min, P < 0.001). The incidence of postoperative complications was similar in both groups, and no cases of stenosis were observed in the LS group. In DG patients, the operative time and gastric-jejunal overlap anastomosis time were significantly shorter in the LS group (294 min vs. 253 min, P = 0.002; 28.5 vs. 9.0 min, P < 0.001). The length of postoperative hospital stay was significantly shorter in the LS group (13 vs. 11 days, P = 0.01). CONCLUSION: Using an LS to close the entry hole in an overlapping anastomosis during minimally invasive gastrectomy can reduce the anastomosis time and may be a safe option without increasing the risk of stenosis.
引用
- Azumi Y, Urakawa N, Kanaji S, et al. Efficacy of a linear stapler in entry hole closure during overlap anastomosis in minimally invasive gastrectomy. Surg Endosc. 2025. PMID: 40246760. doi:10.1007/s00464-025-11736-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。